An experimental study on hybrid fibre reinforced engineered cementitious composite link slabs under static and fatigue loadings

被引:4
|
作者
Zhu, Shiyao [1 ]
Zhang, Y. X. [2 ]
Lee, C. K. [1 ]
机构
[1] Univ New South Wales, Sch Engn & Technol, Canberra, ACT 2600, Australia
[2] Western Sydney Univ, Sch Engn Design & Built Environm, Kingswood, NSW 2751, Australia
关键词
Engineered cementitious composite (ECC); Hybrid fibres; Link slab; Fatigue test; Crack width control; BEHAVIOR; DESIGN;
D O I
10.1016/j.engstruct.2023.117254
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study conducted experimental investigations on the structural performances of link slabs which are con-structed by using a newly developed hybrid-fibre reinforced engineered cementitious composite (hybrid-ECC). Both static and fatigue loadings were applied to validate the feasibility, provide a proof of concept study and demonstrate the benefits using hybrid-ECC for bridge link slabs application. Three identical quarter-scaled hybrid-ECC link slabs, simulating a link slab used for a typical 35-meter multi-span simply supported bridge, were fabricated. These slabs, denoted as LS-1, LS-2 and LS-3, were tested under designated static and fatigue loadings. Slab LS-1 was tested under static loading to obtain the flexural strength of the slab. Slabs LS-2 and LS-3 were tested under fatigue loadings to evaluate their fatigue performances under normal service loading and overload scenarios, respectively. Structural performances of these slabs in terms of deformation and crack width control capability, strain development on reinforcement bars and estimated service life were evaluated. It was observed that multiple microcracks were developed under both static and fatigue loadings. Slab LS-2 survived ten million cycles of service fatigue loading while LS-3 survived two million cycles of overload fatigue loading. For all the tests conducted under static and fatigue loadings, the maximum crack width observed on the three link slab samples was all controlled within the allowable limit of 0.2 mm until failure occurred. Based on the test results, it was estimated that if only the effects due to normal traffic loading and temperature variation were considered, the hybrid-ECC link slab could achieve a service life of more than 40 years. Therefore, the experi-mental study reconfirmed that the hybrid-ECC showed a high potential to improve the fatigue performance and extend the service life of link slab in bridge construction.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Experimental study on the mechanical properties of reinforced engineered cementitious composites
    Yang, Dan
    Wang, Zhiyuan
    Guo, Rui
    Yu, Zhixiang
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2024, 20
  • [32] Mechanical response of textile reinforced cementitious composite tubes under monotonic and cyclic loadings
    Donmez, Didem
    Donmez, A. Abdullah
    Gencoglu, Mustafa
    CONSTRUCTION AND BUILDING MATERIALS, 2020, 251
  • [33] EXPERIMENTAL STUDY OF HYBRID RUBBERIZED COMPOSITE SLABS
    Subashree, P.
    Thenmozhi, R.
    ARCHIVES OF CIVIL ENGINEERING, 2018, 64 (04) : 22 - 29
  • [34] Experimental and Numerical Investigation of Fatigue Performance in Reinforced Concrete Beams Strengthened with Engineered Cementitious Composite Layers and Steel Plates
    Lei, Dongsheng
    Liu, Long
    Ma, Xingpeng
    Luo, Mingdi
    Gong, Yanfen
    COATINGS, 2025, 15 (01):
  • [35] STUDY ON MECHANICAL PROPERTIES OF HYBRID FIBER REINFORCED ENGINEERED CEMENTITIOUS COMPOSITES
    Sridhar, Radhika
    Prasad, Ravi
    REVISTA ROMANA DE MATERIALE-ROMANIAN JOURNAL OF MATERIALS, 2019, 49 (03): : 424 - 433
  • [36] An experimental study on hybrid fibre reinforced concrete
    1600, CAFET INNOVA Technical Society, 1-2-18/103, Mohini Mansion, Gagan Mahal Road,, Domalguda, Hyderabad, 500029, India (07):
  • [37] Deflection Ductility of Slabs Made of Hybrid Mesh-And-Fibre-Reinforced Cementbased Composite
    Sakthivel P.B.
    Sakthivel, P.B. (pbs_ms@yahoo.com), 2017, De Gruyter Open Ltd (63) : 115 - 137
  • [38] Fiber-Reinforced Polymer Strengthening of Steel Beams under Static and Fatigue Loadings
    Bagale, Bibek Regmi
    Parvin, Azadeh
    PRACTICE PERIODICAL ON STRUCTURAL DESIGN AND CONSTRUCTION, 2021, 26 (01)
  • [39] Robustness of hybrid fiber reinforced engineered cementitious composite containing stone processing waste
    Singh, Maninder
    Saini, Babita
    Chalak, H. D.
    SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES, 2024, 49 (02):
  • [40] RC Slabs Repaired and Strengthened by Alumina/Polymer Mortar and Prestressing Strands in the Tension Zone: Experimental Investigation Under Static and Fatigue Loadings
    K. B. Han
    S. N. Hong
    S. K. Park
    Mechanics of Composite Materials, 2012, 48 : 587 - 602