A dual-mass fully decoupled MEMS gyroscope with optimized structural design for minimizing mechanical quadrature coupling

被引:5
|
作者
Wu, Zhongye [1 ]
Feng, Ronghui [1 ]
Sun, Chengliang [1 ,2 ,3 ]
Wang, Peng [4 ]
Wu, Guoqiang [1 ,2 ,3 ]
机构
[1] Wuhan Univ, Inst Technol Sci, Wuhan 430072, Hubei, Peoples R China
[2] Hubei Yangtze Memory Labs, Wuhan 430205, Hubei, Peoples R China
[3] Wuhan Univ, Sch Microelect, Wuhan 430072, Hubei, Peoples R China
[4] Cool Semicond Co Ltd, Shanghai 201800, Peoples R China
关键词
MEMS gyroscope; Fully decoupled; Quadrature coupling; Bias instability; COMPENSATION;
D O I
10.1016/j.mee.2022.111918
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Mechanical quadrature coupling is one of the main sources of zero-rate output in microelectromechanical system (MEMS) gyroscope, which limits the further improvement of gyroscope performance. This paper reports a dualmass MEMS tuning fork gyroscope based on fully decoupled structure. The theoretical analysis and finite element method (FEM) simulation are performed to identify the sources of the mechanical quadrature error in detail and to find ways to optimize the structural design of MEMS gyroscope. The results show that reducing the quadrature coupling stiffness of local sensing components is a key factor in minimizing the overall gyroscope quadrature error. By deliberately optimization of the geometry of the sensing components including sense frame and the drive springs closed to the sense frame, the quadrature induced deformation of sense electrode can be reduced from 160 nm to 5.1 nm with a driving displacement of 1 mu m based on FEM simulation. The equivalent angular rate output caused by quadrature coupling of each sense electrode can be reduced from 3960 degrees/s to 60 degrees/s. The optimized gyroscope operates in split-mode with open-loop readout. The measured scale factor of gyroscope is 90.46 LSB/(degrees/s) with a non-linearity of 810 ppm in the full scale range of +/- 300 degrees/s. The measurement result root 305;shows a bias instability of 8.9 degrees/h and an angular random walk (ARW) of 0.74 degrees/ h at room temperature, respectively. The proposed approach of structural improvements can be used to reduce the quadrature error of the gyroscope in processing tolerances.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] A novel Jully-decoupled dual-mass silicon micromachined gyroscope
    Gao, Yang
    Li, Hongsheng
    Huang, Libin
    Qiu, Xuping
    2016 IEEE TRANSPORTATION ELECTRIFICATION CONFERENCE AND EXPO, ASIA-PACIFIC (ITEC ASIA-PACIFIC), 2016, : 919 - 923
  • [22] Calculation and simulation of silicon MEMS gyroscope with dual-mass resonant output
    Li, Jian-Li
    Fang, Jian-Cheng
    Sheng, Wei
    Dong, Hai-Feng
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2008, 16 (03): : 484 - 491
  • [23] Design of Thermal Dual-Mass MEMS Gyroscope with 2-DoF Drive Mode Oscillator
    Shakoor, Rana I.
    Bazaz, Shafaat A.
    Hasan, M. M.
    ICSE: 2008 IEEE INTERNATIONAL CONFERENCE ON SEMICONDUCTOR ELECTRONICS, PROCEEDINGS, 2008, : 207 - +
  • [24] A dual-mass frequency-modulated (FM) pitch gyroscope: mechanical design and modelling
    Zega, Valentina
    Comi, Claudia
    Fedeli, Patrick
    Frangi, Attilio
    Corigliano, Alberto
    Minotti, Paolo
    Langfelder, Giacomo
    Falorni, Luca
    Tocchio, Alessandro
    2018 5TH IEEE INTERNATIONAL SYMPOSIUM ON INERTIAL SENSORS & SYSTEMS (INERTIAL 2018), 2018, : 61 - 64
  • [25] An Improved Dual-mass Decoupled Micro-gyroscope for the Non-ideal Decoupled Error Suppression
    Yang, Bo
    Hu, Di
    Deng, Yunpeng
    Wang, Xingjun
    2016 3RD IEEE INTERNATIONAL SYMPOSIUM ON INERTIAL SENSORS AND SYSTEMS, 2016, : 58 - 61
  • [26] Design and Experiment of Dual-Mass MEMS Gyroscope Sense Closed System Based on Bipole Compensation Method
    Cao, Huiliang
    Liu, Yu
    Zhang, Yingjie
    Shao, Xingling
    Gao, Jinyang
    Huang, Kun
    Shi, Yunbo
    Tang, Jun
    Shen, Chong
    Liu, Jun
    IEEE ACCESS, 2019, 7 : 49111 - 49124
  • [27] Electrostatic compensation of structural imperfections in dynamically amplified dual-mass gyroscope
    Efimovskaya, Alexandra
    Wang, Danmeng
    Lin, Yu-Wei
    Shkel, Andrei M.
    SENSORS AND ACTUATORS A-PHYSICAL, 2018, 275 : 99 - 108
  • [28] Electrostatic Compensation of Structural Imperfections in Dynamically Amplified Dual-Mass Gyroscope
    Efimovskaya, Alexandra
    Lin, Yu-Wei
    Wang, Danmeng
    Shkel, Andrei M.
    2017 4TH IEEE INTERNATIONAL SYMPOSIUM ON INERTIAL SENSORS AND SYSTEMS (INERTIAL), 2017, : 27 - 30
  • [29] Multi-scale parallel temperature error processing for dual-mass MEMS gyroscope
    Shen, Chong
    Li, Jie
    Zhang, Xiaoming
    Tang, Jun
    Cao, Huiliang
    Liu, Jun
    SENSORS AND ACTUATORS A-PHYSICAL, 2016, 245 : 160 - 168
  • [30] Research of a symmetrical decoupled dual-mass micro-gyroscope with an improved lever support system
    Bo Yang
    Di Hu
    Xingjun Wang
    Lei Wu
    Microsystem Technologies, 2017, 23 : 799 - 810