A mechanistic computational framework to investigate the hemodynamic fingerprint of the blood oxygenation level-dependent signal

被引:0
|
作者
Baez-Yanez, Mario Gilberto [1 ]
Siero, Jeroen C. W. [1 ,2 ]
Petridou, Natalia [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiol, Ctr Image Sci, Utrecht, Netherlands
[2] Royal Netherlands Acad Arts & Sci, Spinoza Ctr Neuroimaging Amsterdam, Amsterdam, Netherlands
基金
美国国家卫生研究院;
关键词
biophysical modeling; BOLD signal; diffusion; hemodynamic response; microvasculature; Monte Carlo simulation; susceptibility; Voronoi tessellation; HUMAN VISUAL-CORTEX; VASCULAR NETWORK; INTRAVASCULAR CONTRIBUTION; MICROVASCULAR NETWORKS; BRAIN ACTIVATION; BOLD RESPONSE; BASE-LINE; SPIN-ECHO; FMRI; MODEL;
D O I
10.1002/nbm.5026
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) is one of the most used imaging techniques to map brain activity or to obtain clinical information about human cortical vasculature, in both healthy and disease conditions. Nevertheless, BOLD fMRI is an indirect measurement of brain functioning triggered by neurovascular coupling. The origin of the BOLD signal is quite complex, and the signal formation thus depends, among other factors, on the topology of the cortical vasculature and the associated hemodynamic changes. To understand the hemodynamic evolution of the BOLD signal response in humans, it is beneficial to have a computational framework available that virtually resembles the human cortical vasculature, and simulates hemodynamic changes and corresponding MRI signal changes via interactions of intrinsic biophysical and magnetic properties of the tissues. To this end, we have developed a mechanistic computational framework that simulates the hemodynamic fingerprint of the BOLD signal based on a statistically defined, three-dimensional, vascular model that approaches the human cortical vascular architecture. The microvasculature is approximated through a Voronoi tessellation method and the macrovasculature is adapted from two-photon microscopy mice data. Using this computational framework, we simulated hemodynamic change-scerebral blood flow, cerebral blood volume, and blood oxygen saturation-induced by virtual arterial dilation. Then we computed local magnetic field disturbances generated by the vascular topology and the corresponding blood oxygen saturation changes. This mechanistic computational framework also considers the intrinsic biophysical and magnetic properties of nearby tissue, such as water diffusion and relaxation properties, resulting in a dynamic BOLD signal response. The proposed mechanistic computational framework provides an integrated biophysical model that can offer better insights regarding the spatial and temporal properties of the BOLD signal changes.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Cortical laminar resting-state signal fluctuations scale with the hypercapnic blood oxygenation level-dependent response
    Guidi, Maria
    Huber, Laurentius
    Lampe, Leonie
    Merola, Alberto
    Ihle, Kristin
    Moeller, Harald E.
    HUMAN BRAIN MAPPING, 2020, 41 (08) : 2014 - 2027
  • [22] Effect of anesthesia on blood oxygenation level-dependent signal changes in response to ingested L-glutamate in rats
    Tsurugizawa, Tomokazu
    Uematsu, Akira
    Uneyama, Hisayuki
    Torii, Kunio
    NEUROSCIENCE RESEARCH, 2009, 65 : S214 - S214
  • [23] Numerical simulation of the blood oxygenation level-dependent functional magnetic resonance signal using finite element method
    Mangini, Fabio
    DiNuzzo, Mauro
    Maugeri, Laura
    Moraschi, Marta
    Mascali, Daniele
    Cedola, Alessia
    Frezza, Fabrizio
    Giove, Federico
    Fratini, Michela
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2020, 36 (02)
  • [24] Blood Oxygenation Level-Dependent MRI to Assess Renal Oxygenation in Renal Diseases: Progresses and Challenges
    Pruijm, Menno
    Milani, Bastien
    Burnier, Michel
    FRONTIERS IN PHYSIOLOGY, 2017, 7
  • [25] Comparison of 1H Blood Oxygen Level-Dependent (BOLD) and 19F MRI to Investigate Tumor Oxygenation
    Zhao, Dawen
    Jiang, Lan
    Hahn, Eric W.
    Mason, Ralph P.
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (02) : 357 - 364
  • [26] Blood oxygenation level-dependent MRI of cerebral gliomas during breath holding
    Hsu, YY
    Chang, CN
    Jung, SM
    Lim, KE
    Huang, JC
    Fang, SY
    Liu, HL
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (02) : 160 - 167
  • [27] Postcontractile blood oxygenation level-dependent (BOLD) response in Duchenne muscular dystrophy
    Lopez, Christopher
    Taivassalo, Tanja
    Berru, Maria G.
    Saavedra, Andres
    Rasmussen, Hannah C.
    Batra, Abhinandan
    Arora, Harneet
    Roetzheim, Alex M.
    Walter, Glenn A.
    Vandenborne, Krista
    Forbes, Sean C.
    JOURNAL OF APPLIED PHYSIOLOGY, 2021, 131 (01) : 83 - 94
  • [28] Estimation of physiological sources of nonlinearity in blood oxygenation level-dependent contrast signals
    Kang, Daehun
    Sung, Yul-Wan
    Shioiri, Satoshi
    MAGNETIC RESONANCE IMAGING, 2018, 46 : 121 - 129
  • [29] Blood oxygenation level-dependent (BOLD)-based techniques for the quantification of brain hemodynamic and metabolic properties - theoretical models and experimental approaches
    Yablonskiy, Dmitriy A.
    Sukstanskii, Alexander L.
    He, Xiang
    NMR IN BIOMEDICINE, 2013, 26 (08) : 963 - 986
  • [30] MR blood oxygenation level-dependent signal differences in parenchymal and large draining vessels: Implications for functional MR imaging
    Krings, T
    Erberich, SG
    Roessler, F
    Reul, J
    Thron, A
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1999, 20 (10) : 1907 - 1914