Multi-parametric optimization of magnetic resonance imaging sequences for magnetic resonance-guided radiotherapy

被引:0
|
作者
Fahad, Hafiz Muhammad [1 ,2 ,3 ]
Dorsch, Stefan [1 ,3 ,4 ]
Zaiss, Moritz [5 ,6 ]
Karger, Christian P. [1 ,3 ]
机构
[1] German Canc Res Ctr, Med Phys Radiat Oncol, Heidelberg, Germany
[2] Heidelberg Univ, Fac Med, Heidelberg, Germany
[3] Heidelberg Inst Radiat Oncol HIRO, Natl Ctr Radiat Res Oncol NCRO, Heidelberg, Germany
[4] Heidelberg Univ Hosp, Dept Radiat Oncol, Heidelberg, Germany
[5] Friedrich Alexander Univ Erlangen Nurnberg FAU, Univ Hosp Erlangen, Inst Neuroradiol, Erlangen, Germany
[6] Max Planck Inst Biol Cyberrnet, Magnet Resonance Ctr, Tubingen, Germany
关键词
Contrast maximization; MR-guided radiotherapy; Remote control MRI; Supervised learning; MR sequences optimization; MRI SCANNER; CANCER;
D O I
10.1016/j.phro.2023.100497
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Magnetic Resonance Imaging (MRI) is widely used in oncology for tumor staging, treatment response assessment, and radiation therapy (RT) planning. This study proposes a framework for automatic optimization of MRI sequences based on pulse sequence parameter sets (SPS) that are directly applied on the scanner, for application in RT planning.Materials and methods: A phantom with seven in-house fabricated contrasts was used for measurements. The proposed framework employed a derivative-free optimization algorithm to repeatedly update and execute a parametrized sequence on the MR scanner to acquire new data. In each iteration, the mean-square error was calculated based on the clinical application. Two clinically relevant optimization goals were pursued: achieving the same signal and therefore contrast as in a target image, and maximizing the signal difference (contrast) between specified tissue types. The framework was evaluated using two optimization methods: a covariance matrix adaptation evolution strategy (CMA-ES) and a genetic algorithm (GA). Results: The obtained results demonstrated the potential of the proposed framework for automatic optimization of MRI sequences. Both CMA-ES and GA methods showed promising results in achieving the two optimization goals, however, CMA-ES converged much faster as compared to GA.Conclusions: The proposed framework enables for automatic optimization of MRI sequences based on SPS that are directly applied on the scanner and it may be used to enhance the quality of MRI images for dedicated applications in MR-guided RT.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Magnetic Resonance-Guided Prostate Ablation
    Woodrum, David A.
    Kawashima, Akira
    Gorny, Krzysztof R.
    Mynderse, Lance A.
    SEMINARS IN INTERVENTIONAL RADIOLOGY, 2019, 36 (05) : 351 - 366
  • [22] Magnetic Resonance-Guided Drug Delivery
    Mikhail, Andrew S.
    Partanen, Ari
    Yarmolenko, Pavel
    Venkatesan, Aradhana M.
    Wood, Bradford J.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2015, 23 (04) : 643 - +
  • [23] Magnetic resonance-guided focused ultrasound
    Albuquerque, Felipe C.
    NEUROSURGICAL FOCUS, 2013, 34 (05)
  • [24] MAGNETIC RESONANCE-GUIDED THERMAL SURGERY
    CLINE, HE
    SCHENCK, JF
    WATKINS, RD
    HYNYNEN, K
    JOLESZ, FA
    MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (01) : 98 - 106
  • [25] Magnetic Resonance-Guided Gynecologic Brachytherapy
    Damato, Antonio L.
    Viswanathan, Akila N.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2015, 23 (04) : 633 - +
  • [26] Magnetic Resonance-Guided Prostate Biopsy
    Dianat, S. Saeid
    Carter, H. Ballentine
    Macura, Katarzyna J.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2015, 23 (04) : 621 - +
  • [27] A prototype manipulator for magnetic resonance-guided interventions inside standard cylindrical magnetic resonance imaging scanners
    Tsekos, NV
    Özcan, A
    Christoforou, E
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (06): : 972 - 980
  • [28] Feasibility of magnetic resonance-guided adaptive post-prostatectomy radiotherapy
    Hassan, S.
    Jameson, M.
    Batumalai, V.
    Crawford, D.
    Moutrie, Z.
    Hogan, L.
    Loo, C.
    Picton, M.
    Pagulayan, C.
    Jelen, U.
    Alvares, S.
    Heinke, M.
    Sampaio, S.
    Simon, K.
    Twentyman, T.
    Dwivedi, N.
    de Leon, J.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1166 - S1167
  • [29] Rare localization of tongue vascular lesion detected by multi-parametric magnetic resonance imaging
    Gilardi, Antonio
    Ralli, Massimo
    Colizza, Andrea
    Di Stadio, Arianna
    Messineo, Daniela
    Riminucci, Mara
    Corsi, Alessandro
    Greco, Antonio
    de Vincentiis, Marco
    CLINICAL CASE REPORTS, 2022, 10 (01):
  • [30] Temporal profile of transient focal ischemia assessed by multi-parametric magnetic resonance imaging
    Okubo, S
    Igarashi, H
    Sakamaki, M
    Mizukoshi, G
    Katayama, Y
    STROKE, 2004, 35 (06) : E250 - E250