Interference of bovine hemoglobin-based oxygen carrier-201 (Hemopure) on four hematology analyzers

被引:1
|
作者
Bronkhorst-van Der Helm, Marinke W. [1 ]
Weerkamp, Floor [2 ]
Huisman, Albert [3 ]
Huisman, Elise J. [4 ,5 ]
Russcher, Henk [1 ,6 ]
机构
[1] Erasmus MC, Dept Clin Chem, Univ Med Ctr, Rotterdam, Netherlands
[2] Maasstad Hosp, Dept Clin Chem, Rotterdam, Netherlands
[3] Univ Med Ctr Utrecht, Cent Diagnost Lab, Utrecht, Netherlands
[4] Erasmus MC, Sophia Childrens Hosp, Dept Pediat Hematol, Rotterdam, Netherlands
[5] Sanquin Blood Bank, Unit Transfus Med, Amsterdam, Netherlands
[6] Erasmus MC, Dept Clin Chem, Dr Molewaterplein 40, NL-3015 GD Rotterdam, Netherlands
关键词
extracellular hemoglobin; hematology analyzer; hemoglobin-based oxygen carrier; interference; intracellular hemoglobin; HBOC-201;
D O I
10.1111/ijlh.14146
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Hemoglobin-based oxygen carriers, for example HBOC-201 (Hemopure), are aimed to bridge acute anemia when blood transfusion is not available or refused by the patient. However, since HBOC-201 appears free in plasma, it interferes with laboratory tests. This study presents an overview of HBOC-201 interference on four commonly used hematology analyzers and suggests treatment monitoring possibilities.Methods: Blood samples were spiked with therapeutic doses of HBOC-201 and nine hematology parameters were measured with the Sysmex XN-20, Siemens Advia 2120i, Abbott Alinity Hq and Abbot Cell Dyn Sapphire hematology analyzers. The results were compared to control samples and the bias was determined.Results: Most parameters, including all cell counts, hematocrit and MCV, showed a non-significant bias compared to control. However, the standard, total hemoglobin (Hb) measurement as well as MCH and MCHC showed poor agreement with control, as HBOC-201 was included in this measurement. Yet, the flow cytometry-based Hb method quantified intracellular Hb in spiked samples, excluding HBOC-201.Conclusion: Of all included hematology parameters, only total Hb and the associated MCH and MCHC suffered from interference. In contrast, the flow cytometry-based Hb measurement provided an accurate measure of intracellular Hb. The difference between total Hb and cellular Hb represents the HBOC-201 concentration and can be used to monitor HBOC-201 treatment.
引用
收藏
页码:869 / 874
页数:6
相关论文
共 50 条
  • [31] Does a Hemoglobin-Based Oxygen Carrier Affect Hemostatic Function?
    Meledeo, Michael A.
    Peltier, Grantham C.
    McIntosh, Colby S.
    Taylor, Ashley S.
    Bynum, James A.
    Pusateri, Anthony E.
    Cap, Andrew P.
    TRANSFUSION, 2017, 57 : 170A - 170A
  • [32] Physiology and pharmacokinetics of a novel hemoglobin-based oxygen carrier in humans
    Hughes, GS
    Antal, EJ
    Locker, PK
    Francom, SF
    Adams, WJ
    Jacobs, EE
    CRITICAL CARE MEDICINE, 1996, 24 (05) : 756 - 764
  • [33] Resuscitation from hemorrhagic shock comparing standard hemoglobin-based oxygen carrier (HBOC)-201 versus 7.5% hypertonic HBOC-201
    Rivera-Chavez, Fernando A.
    Huerta, Sergio
    Brown, Ronnie
    York, Gregory B.
    Minei, Joseph P.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2007, 63 (05): : 1113 - 1119
  • [34] Inadequacy of low-volume resuscitation with hemoglobin-based oxygen carrier hemoglobin glutamer-200 (bovine) in canine hypovolemia
    Driessen, B
    Jahr, JS
    Lurie, F
    Gunther, RA
    JOURNAL OF VETERINARY PHARMACOLOGY AND THERAPEUTICS, 2001, 24 (01) : 61 - 71
  • [35] The polymerized bovine hemoglobin-based oxygen-carrying solution (HBOC-201) is not toxic to neural cells in culture
    Ortegon, DP
    Davis, MR
    Dixon, PS
    Smith, DL
    Josephs, JD
    Mueller, DL
    Jenkins, DH
    Kerby, JD
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2002, 53 (06): : 1068 - 1072
  • [36] HEMOGLOBIN-BASED OXYGEN CARRIER PRESERVES SUBMAXIMAL EXERCISE CAPACITY IN HUMANS
    HUGHES, GS
    YANCEY, EP
    ALBRECHT, R
    LOCKER, PK
    FRANCOM, SF
    ORRINGER, EP
    ANTAL, EJ
    JACOBS, EE
    CLINICAL PHARMACOLOGY & THERAPEUTICS, 1995, 58 (04) : 434 - 443
  • [37] Hemoglobin-based oxygen carrier and trials to substitute red blood cells
    Smani, Y.
    Labrude, R.
    Vigneron, C.
    Faivre, B.
    TRANSFUSION CLINIQUE ET BIOLOGIQUE, 2007, 14 (05) : 464 - 473
  • [38] Resuscitation with a hemoglobin-based oxygen carrier after severe brain trauma
    King, DR
    Cohn, S
    Proctor, K
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2004, 199 (03) : S45 - S45
  • [39] Resuscitation with a hemoglobin-based oxygen carrier after traumatic brain injury
    King, DR
    Cohn, SM
    Proctor, KG
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2005, 59 (03): : 553 - 560
  • [40] A hemoglobin-based oxygen carrier sensitized Cisplatin based chemotherapy in hepatocellular carcinoma
    Qi, Xiang
    Wong, Bing L.
    Lau, Sze Hang
    Ng, Kevin Tak-Pan
    Kwok, Sui Yi
    Sun, Chris Kin-Wai
    Tzang, Fei Chuen
    Shao, Yan
    Li, Chang Xian
    Geng, Wei
    Ling, Chang Chun
    Ma, Yuen Yuen
    Liu, Xiao Bing
    Liu, Hui
    Liu, Jiang
    Yeung, Wai Ho
    Lo, Chung Mau
    Man, Kwan
    ONCOTARGET, 2017, 8 (49) : 85311 - 85325