Interference of bovine hemoglobin-based oxygen carrier-201 (Hemopure) on four hematology analyzers

被引:1
|
作者
Bronkhorst-van Der Helm, Marinke W. [1 ]
Weerkamp, Floor [2 ]
Huisman, Albert [3 ]
Huisman, Elise J. [4 ,5 ]
Russcher, Henk [1 ,6 ]
机构
[1] Erasmus MC, Dept Clin Chem, Univ Med Ctr, Rotterdam, Netherlands
[2] Maasstad Hosp, Dept Clin Chem, Rotterdam, Netherlands
[3] Univ Med Ctr Utrecht, Cent Diagnost Lab, Utrecht, Netherlands
[4] Erasmus MC, Sophia Childrens Hosp, Dept Pediat Hematol, Rotterdam, Netherlands
[5] Sanquin Blood Bank, Unit Transfus Med, Amsterdam, Netherlands
[6] Erasmus MC, Dept Clin Chem, Dr Molewaterplein 40, NL-3015 GD Rotterdam, Netherlands
关键词
extracellular hemoglobin; hematology analyzer; hemoglobin-based oxygen carrier; interference; intracellular hemoglobin; HBOC-201;
D O I
10.1111/ijlh.14146
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Hemoglobin-based oxygen carriers, for example HBOC-201 (Hemopure), are aimed to bridge acute anemia when blood transfusion is not available or refused by the patient. However, since HBOC-201 appears free in plasma, it interferes with laboratory tests. This study presents an overview of HBOC-201 interference on four commonly used hematology analyzers and suggests treatment monitoring possibilities.Methods: Blood samples were spiked with therapeutic doses of HBOC-201 and nine hematology parameters were measured with the Sysmex XN-20, Siemens Advia 2120i, Abbott Alinity Hq and Abbot Cell Dyn Sapphire hematology analyzers. The results were compared to control samples and the bias was determined.Results: Most parameters, including all cell counts, hematocrit and MCV, showed a non-significant bias compared to control. However, the standard, total hemoglobin (Hb) measurement as well as MCH and MCHC showed poor agreement with control, as HBOC-201 was included in this measurement. Yet, the flow cytometry-based Hb method quantified intracellular Hb in spiked samples, excluding HBOC-201.Conclusion: Of all included hematology parameters, only total Hb and the associated MCH and MCHC suffered from interference. In contrast, the flow cytometry-based Hb measurement provided an accurate measure of intracellular Hb. The difference between total Hb and cellular Hb represents the HBOC-201 concentration and can be used to monitor HBOC-201 treatment.
引用
收藏
页码:869 / 874
页数:6
相关论文
共 50 条
  • [1] EVALUATION OF THE SAFETY AND TOLERANCE OF HEMOGLOBIN-BASED OXYGEN CARRIER-201
    MONK, T
    GOODNOUGH, L
    HUGHES, G
    JACOBS, E
    ANESTHESIOLOGY, 1995, 83 (3A) : A285 - A285
  • [2] Analytical interference of HBOC-201 (Hemopure, a synthetic hemoglobin-based oxygen carrier) on four common clinical chemistry platforms
    Korte, Erik A.
    Pozzi, Nicole
    Wardrip, Nina
    Ayyoubi, M. Tayyeb
    Jortani, Saeed A.
    CLINICA CHIMICA ACTA, 2018, 482 : 33 - 39
  • [3] Effect of hemoglobin-based oxygen carrier-201 on common chemistry laboratory procedures
    Sarkozi, L
    Jacobs, E
    Clark, T
    Gawryl, MS
    Simson, E
    CLINICAL CHEMISTRY, 1997, 43 (09) : 1792 - 1794
  • [4] Normalization of hemoglobin-based oxygen carrier-201 induced vasoconstriction: targeting nitric oxide and endothelin
    Taverne, Yannick J.
    de Wijs-Meijler, Daphne
    Hekkert, Maaike te Lintel
    Moon-Massat, Paula F.
    Dube, Gregory P.
    Duncker, Dirk J.
    Merkus, Daphne
    JOURNAL OF APPLIED PHYSIOLOGY, 2017, 122 (05) : 1227 - 1237
  • [5] The pharmacology of tissue oxygenation by Biopure's hemoglobin-based oxygen carrier, Hemopure® (HBOC-201)
    Pearce, LB
    Gawryl, MS
    OXYGEN TRANSPORT TO TISSUE XXIV, 2003, 530 : 261 - 270
  • [6] A dose-escalation study to evaluate the kinetics and hemodynamic effects of hemoglobin-based oxygen carrier-201
    Monk, TG
    Goodenough, LT
    Peruzzi, WT
    Byers, PM
    Jacobs, EE
    Silverman, MH
    ANESTHESIOLOGY, 1997, 87 (03) : A214 - A214
  • [7] Lactate measurement interference by hemoglobin-based oxygen carriers (Oxyglobin®, Hemopure®, and HemollinkTM)
    Jahr, JS
    Osgood, S
    Rothenberg, SJ
    Li, QL
    Butch, AW
    Gunther, R
    Cheung, A
    Driessen, B
    ANESTHESIA AND ANALGESIA, 2005, 100 (02): : 431 - 436
  • [8] Selective aortic arch perfusion with hemoglobin-based oxygen carrier-201 for resuscitation from exsanguinating cardiac arrest in swine
    Manning, JE
    Katz, LM
    Pearce, LB
    Batson, DN
    McCurdy, SL
    Gawryl, MS
    Baker, CC
    CRITICAL CARE MEDICINE, 2001, 29 (11) : 2067 - 2074
  • [9] A PEGylated bovine hemoglobin as a potent hemoglobin-based oxygen carrier
    Wang, Ying
    Wang, Linli
    Yu, Weili
    Gao, Dawei
    You, Guoxing
    Li, Penglong
    Zhang, Shan
    Zhang, Jun
    Hu, Tao
    Zhao, Lian
    Zhou, Hong
    BIOTECHNOLOGY PROGRESS, 2017, 33 (01) : 252 - 260
  • [10] Innate immune responses in swine resuscitated from severe traumatic hemorrhagic shock with hemoglobin-based oxygen carrier-201
    Hall, C.
    Malkevich, N.
    Handrigan, M.
    VanderMolen, C.
    Aranaud, F.
    Hong, J.
    Dong, F.
    Rice, J.
    Philbin, N.
    Ahlers, S.
    McCarron, R.
    Freilich, D.
    McGwin, G.
    Flournoy, W. S.
    Pearce, L. Bruce
    ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY, 2007, 35 (03): : 259 - 274