Addressing the sample volume dependency of the colorimetric glucose measurement on microfluidic paper-based and thread/paper-based analytical devices using a novel low-cost analytical viewpoint

被引:1
|
作者
Derakhshani, Mohammad [1 ]
Jahanshahi, Amir [1 ]
Ghourchian, Hedayatollah [2 ]
机构
[1] Amirkabir Univ Technol, Tehran Polytech, Dept Elect Engn, Micro Bio Technol Lab MBTechLab, Tehran, Iran
[2] Univ Tehran, Inst Biochem & Biophys, Lab Bioanal, Tehran, Iran
关键词
Paper-based microfluidics; Thread/paper-based microfluidics; Colorimetry; Sample volume; Glucose; Machine learning; ELECTROCHEMICAL SENSOR; DIAGNOSTICS;
D O I
10.1016/j.microc.2023.109545
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The colorimetric method is widely exploited for glucose measurement on microfluidic paper-based and microfluidic thread/paper-based analytical devices, mu PADs and mu TPADs, respectively. However, two significant challenges still hinder the real-world applications: the variation of the generated color based on sample volume variation, and the consistent dependency on an imaging camera - usually a smartphone camera - for color readout. The latter also suffers from multiple limitations, such as the variable ambient light conditions and imaging variation among different smartphone brands and models. This manuscript suggests a new device demonstrating a novel viewpoint to the colorimetric method to address both aforementioned challenges. The presented device, Volume-Independent Autonomous box (VIA box), continuously monitors the transient color of the mu PAD upon the introduction of the sample till color stabilization, in contrast to similar studies where merely the final stabilized color is read. The interpretation of the transient color profile with respect to time results in the measurement of the glucose level independent of sample volume. In addition, the VIA box monitors mu PAD's color using an ordinary RGB sensor instead of an imaging camera in similar studies. Since merely RGB values are recorded in any measurement instance, the computational cost is extremely low compared to the relevant literature where image processing techniques are used. VIA box exploits a simple low-end microcontroller to continuously monitor the transient color, interpret the color profile, and show the glucose level. The samples used in this manuscript are made of artificial sweat samples, including the known glucose range in real sweat samples.
引用
收藏
页数:10
相关论文
共 50 条
  • [11] USB powered microfluidic paper-based analytical devices
    Schaumburg, Federico
    Kler, Pablo A.
    Carrell, Cody S.
    Berli, Claudio L. A.
    Henry, Charles S.
    ELECTROPHORESIS, 2020, 41 (7-8) : 562 - 569
  • [12] Low-cost precision agriculture for sustainable farming using paper-based analytical devices
    Albuquerque, Jessica Rodrigues de Paula
    Makara, Cleyton Nascimento
    Ferreira, Vinicius Guimaraes
    Brazaca, Lais Canniatti
    Carrilho, Emanuel
    RSC ADVANCES, 2024, 14 (32) : 23392 - 23403
  • [13] Fully Enclosed Microfluidic Paper-Based Analytical Devices
    Schilling, Kevin M.
    Lepore, Anna L.
    Kurian, Jason A.
    Martinez, Andres W.
    ANALYTICAL CHEMISTRY, 2012, 84 (03) : 1579 - 1585
  • [14] Microfluidic Paper-based Analytical Devices in Clinical Applications
    Tingting Han
    Yuhang Jin
    Chunyang Geng
    Aziz ur Rehman Aziz
    Yang Zhang
    Sha Deng
    Haijun Ren
    Bo Liu
    Chromatographia, 2020, 83 : 693 - 701
  • [15] Microfluidic paper-based analytical devices for cancer diagnosis
    Shalaby, Ahmed A.
    Tsao, Chia-Wen
    Ishida, Akihiko
    Maeki, Masatoshi
    Tokeshi, Manabu
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 379
  • [16] Microfluidic Paper-based Analytical Devices in Clinical Applications
    Han, Tingting
    Jin, Yuhang
    Geng, Chunyang
    Aziz, Aziz Ur Rehman
    Zhang, Yang
    Deng, Sha
    Ren, Haijun
    Liu, Bo
    CHROMATOGRAPHIA, 2020, 83 (06) : 693 - 701
  • [17] From Microfluidic Paper-Based Analytical Devices to Paper-Based Biofluidics with Integrated Continuous Perfusion
    Wu, Yan
    Gao, Qing
    Nie, Jing
    Fu, Jian-Zhong
    He, Yong
    ACS BIOMATERIALS SCIENCE & ENGINEERING, 2017, 3 (04): : 601 - 607
  • [18] Blood separation on microfluidic paper-based analytical devices
    Songjaroen, Temsiri
    Dungchai, Wijitar
    Chailapakul, Orawon
    Henry, Charles S.
    Laiwattanapaisal, Wanida
    LAB ON A CHIP, 2012, 12 (18) : 3392 - 3398
  • [19] Paper-based microfluidic analytical devices for colorimetric detection of toxic ions: A review
    Sriram, Ganesan
    Bhat, Mahesh P.
    Patil, Pravin
    Uthappa, Uluvangada T.
    Jung, Ho-Young
    Altalhi, Tariq
    Kumeria, Tushar
    Aminabhavi, Tejraj M.
    Pai, Ranjith Krishna
    Madhuprasad
    Kurkuri, Mahaveer D.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2017, 93 : 212 - 227
  • [20] 3D microfluidic paper-based analytical devices for colorimetric bioassays
    Neris, Natalia
    Wong, Alyssa
    Fernandez, Alyssa
    Gomez, Frank
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 258