Addressing the sample volume dependency of the colorimetric glucose measurement on microfluidic paper-based and thread/paper-based analytical devices using a novel low-cost analytical viewpoint

被引:1
|
作者
Derakhshani, Mohammad [1 ]
Jahanshahi, Amir [1 ]
Ghourchian, Hedayatollah [2 ]
机构
[1] Amirkabir Univ Technol, Tehran Polytech, Dept Elect Engn, Micro Bio Technol Lab MBTechLab, Tehran, Iran
[2] Univ Tehran, Inst Biochem & Biophys, Lab Bioanal, Tehran, Iran
关键词
Paper-based microfluidics; Thread/paper-based microfluidics; Colorimetry; Sample volume; Glucose; Machine learning; ELECTROCHEMICAL SENSOR; DIAGNOSTICS;
D O I
10.1016/j.microc.2023.109545
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The colorimetric method is widely exploited for glucose measurement on microfluidic paper-based and microfluidic thread/paper-based analytical devices, mu PADs and mu TPADs, respectively. However, two significant challenges still hinder the real-world applications: the variation of the generated color based on sample volume variation, and the consistent dependency on an imaging camera - usually a smartphone camera - for color readout. The latter also suffers from multiple limitations, such as the variable ambient light conditions and imaging variation among different smartphone brands and models. This manuscript suggests a new device demonstrating a novel viewpoint to the colorimetric method to address both aforementioned challenges. The presented device, Volume-Independent Autonomous box (VIA box), continuously monitors the transient color of the mu PAD upon the introduction of the sample till color stabilization, in contrast to similar studies where merely the final stabilized color is read. The interpretation of the transient color profile with respect to time results in the measurement of the glucose level independent of sample volume. In addition, the VIA box monitors mu PAD's color using an ordinary RGB sensor instead of an imaging camera in similar studies. Since merely RGB values are recorded in any measurement instance, the computational cost is extremely low compared to the relevant literature where image processing techniques are used. VIA box exploits a simple low-end microcontroller to continuously monitor the transient color, interpret the color profile, and show the glucose level. The samples used in this manuscript are made of artificial sweat samples, including the known glucose range in real sweat samples.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Microfluidic Paper-Based Analytical Devices for Colorimetric Detection of Lactoferrin
    Kudo, Hiroko
    Maejima, Kento
    Hiruta, Yuki
    Citterio, Daniel
    SLAS TECHNOLOGY, 2020, 25 (01): : 47 - 57
  • [2] Microfluidic paper-based analytical devices: from POCKET to paper-based ELISA
    Martinez, Andres W.
    BIOANALYSIS, 2011, 3 (23) : 2589 - 2592
  • [3] Microfluidic paper-based analytical devices fabricated by low-cost photolithography and embossing of Parafilm®
    Yu, Ling
    Shi, Zhuan Zhuan
    LAB ON A CHIP, 2015, 15 (07) : 1642 - 1645
  • [4] A Review on Microfluidic Paper-Based Analytical Devices for Glucose Detection
    Liu, Shuopeng
    Su, Wenqiong
    Ding, Xianting
    SENSORS, 2016, 16 (12) : 1 - 17
  • [5] A colorimetric assay system for dopamine using microfluidic paper-based analytical devices
    Liu, Chunye
    Gomez, Frank A.
    Miao, Yanqing
    Cui, Ping
    Lee, Wilson
    TALANTA, 2019, 194 : 171 - 176
  • [6] "Paper-based Analytical Devices"
    不详
    Analytical Sciences, 2017, 33 (3) : 259 - 259
  • [7] Paper-based Analytical Devices
    Hisamoto, Hideaki
    ANALYTICAL SCIENCES, 2017, 33 (07) : 753 - 753
  • [8] Quantification of Colorimetric Data for Paper-Based Analytical Devices
    Soda, Yoshiki
    Bakker, Eric
    ACS SENSORS, 2019, 4 (12) : 3093 - 3101
  • [9] Paper-based Analytical Devices
    Hideaki Hisamoto
    Analytical Sciences, 2017, 33 : 753 - 753
  • [10] Paper-based analytical devices
    Citterio, Daniel
    Kaneta, Takashi
    Analytical Sciences, 2018, 34 (01) : 5 - 6