Microfluidic Paper-Based Analytical Devices for Colorimetric Detection of Lactoferrin

被引:40
|
作者
Kudo, Hiroko [1 ]
Maejima, Kento [1 ]
Hiruta, Yuki [1 ]
Citterio, Daniel [1 ]
机构
[1] Keio Univ, Dept Appl Chem, Yokohama, Kanagawa, Japan
来源
SLAS TECHNOLOGY | 2020年 / 25卷 / 01期
关键词
lactoferrin; colorimetric detection; microfluidic paper-based analytical devices; mu PADs; BOVINE SERUM-ALBUMIN; PATTERNED PAPER; ASSAY; FLOW; IMMUNOASSAY; PLATFORM; PROTEIN; QUANTIFICATION; FLUORESCENCE; FABRICATION;
D O I
10.1177/2472630319884031
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Lactoferrin is an abundant glycoprotein in human body fluids and is known as a biomarker for various diseases. Therefore, point-of-care testing (POCT) for lactoferrin is of interest. Microfluidic paper-based analytical devices (mu PADs) have gained a lot of attention as next-generation POCT device candidates, due to their inexpensiveness, operational simplicity, and being safely disposable. This work presents a colorimetric sensing approach for quantitative lactoferrin analysis. The detection mechanism takes advantage of the high affinity of lactoferrin to ferric ions (Fe3+). Lactoferrin is able to displace an indicator from a colorimetric 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP)-Fe3+ complex, resulting in a color change. A 5-Br-PADAP-Fe3+ complex was encapsulated into water-dispersible poly(styrene-block-vinylpyrrolidone) particles, whose physical entrapment in the cellulosic fiber network results in the immobilization of the complex to the paper matrix. The complex-encapsulating particles showed a color change response in accordance with lactoferrin concentration. Both color intensity-based paper well plates and distance readout-based mu PADs are demonstrated. Color intensity-based devices allowed quantitative analysis of lactoferrin concentrations with a limit of detection of 110 mu g/mL, using a smartphone and a color readout app. On the other hand, distance readout-based mu PADs showed changes of the length of colored sections in accordance with lactoferrin concentration. In summary, we successfully developed both colorimetric intensity-based paper wells and distance-based mu PADs for lactoferrin detection. This work demonstrates a user-friendly colorimetric analysis platform for lactoferrin without requiring lab equipment and expensive antibodies.
引用
收藏
页码:47 / 57
页数:11
相关论文
共 50 条
  • [1] Paper-based microfluidic analytical devices for colorimetric detection of toxic ions: A review
    Sriram, Ganesan
    Bhat, Mahesh P.
    Patil, Pravin
    Uthappa, Uluvangada T.
    Jung, Ho-Young
    Altalhi, Tariq
    Kumeria, Tushar
    Aminabhavi, Tejraj M.
    Pai, Ranjith Krishna
    Madhuprasad
    Kurkuri, Mahaveer D.
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2017, 93 : 212 - 227
  • [2] Technical aspects and challenges of colorimetric detection with microfluidic paper-based analytical devices (μPADs) - A review
    Morbioli, Giorgio Gianini
    Mazzu-Nascimento, Thiago
    Stockton, Amanda M.
    Carrilho, Emanuel
    [J]. ANALYTICA CHIMICA ACTA, 2017, 970 : 1 - 22
  • [3] A Review on Microfluidic Paper-Based Analytical Devices for Glucose Detection
    Liu, Shuopeng
    Su, Wenqiong
    Ding, Xianting
    [J]. SENSORS, 2016, 16 (12) : 1 - 17
  • [4] Detection methods and applications of microfluidic paper-based analytical devices
    Fu, Lung-Ming
    Wang, Yao-Nan
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2018, 107 : 196 - 211
  • [5] Colorimetric Detection of Alkaline Phosphatase on Microfluidic Paper-based Analysis Devices
    Chen Xi
    Chen Jin
    Zhang Hui-Yan
    Wang Fu-Bing
    Wang Fang-Fang
    Ji Xing-Hu
    He Zhi-Ke
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (04) : 591 - 596
  • [6] A colorimetric assay system for dopamine using microfluidic paper-based analytical devices
    Liu, Chunye
    Gomez, Frank A.
    Miao, Yanqing
    Cui, Ping
    Lee, Wilson
    [J]. TALANTA, 2019, 194 : 171 - 176
  • [7] 3D microfluidic paper-based analytical devices for colorimetric bioassays
    Neris, Natalia
    Wong, Alyssa
    Fernandez, Alyssa
    Gomez, Frank
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 258
  • [8] Simultaneous colorimetric detection of improvised explosive compounds using microfluidic paper-based analytical devices (μPADs)
    Peters, Kelley L.
    Corbin, Inge
    Kaufman, Lindsay M.
    Zreibe, Kyle
    Blanes, Lucas
    McCord, Bruce R.
    [J]. ANALYTICAL METHODS, 2015, 7 (01) : 63 - 70
  • [9] Microfluidic paper-based analytical devices for colorimetric detection of urinary tract infection biomarkers on adult diapers
    Chen, Chaohao
    Dong, Tao
    [J]. 2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 5892 - 5895
  • [10] Electrochemical microfluidic paper-based analytical devices for tumor marker detection
    Yuan, Yingying
    Liu, Bo
    Wang, Tianlu
    Li, Na
    Zhang, Zhengyao
    Zhang, Hangyu
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2022, 157