Human femur fracture by mechanical compression: Towards the repeatability of bone fracture acquisition

被引:5
|
作者
Perez-Cano, F. D. [1 ]
Jimenez-Perez, J. R. [1 ]
Molina-Viedma, A. J. [2 ]
Lopez-Alba, E. [2 ]
Luque-Luque, A. [1 ]
Delgado-Martinez, A. [3 ,4 ]
Diaz-Garrido, F. A. [2 ]
Jimenez-Delgado, J. J. [1 ]
机构
[1] Univ Jaen, Graph & Geomat Grp Jaen, Jaen, Spain
[2] Univ Jaen, Dept Mech & Min Engn, Jaen, Spain
[3] Complejo Hosp Jaen, Dept Orthoped Surg, Jaen, Spain
[4] Univ Jaen, Dept Hlth Sci, Jaen, Spain
关键词
Bone fracture; Image analysis; Strain analysis; CORTICAL BONE; CRACK-PROPAGATION; SIMULATION; STRENGTH; GEOMETRY; ANATOMY; DAMAGE; RISK; AXIS;
D O I
10.1016/j.compbiomed.2023.107249
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The increase in life expectancy combined with greater bone fragility over the years is causing a rise in the bone fracture cases. Femur fractures are the most important due to their high mortality rate. This multidisciplinary work is carried out in this context and focuses on the experimental reproduction of human femur fractures by compression. We describe a sequence of steps supervised by orthopaedic surgeons for the correct arrangement of specimens on the system set up to perform the experiment. The device applies force by compression until the human bone is fractured. All tests performed have been monitored and evaluated from different knowledge perspectives. The results obtained have demonstrated the repeatability of the fracture type in a controlled environment as well as identifying the main features involved in this process. In addition, the fractured bones have been digitized to analyze the fracture zone to recreate and evaluate future simulations.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Ununited fracture of the neck of the femur treated by the aid of the bone graft
    Henderson, MS
    JOURNAL OF BONE AND JOINT SURGERY, 1940, 22 : 97 - 106
  • [22] An improved murine femur fracture device for bone healing studies
    Marturano, Joseph E.
    Cleveland, Benjamin C.
    Byrne, Melissa A.
    O'Connell, Shannon L.
    Wixted, John J.
    Billiar, Kristen L.
    JOURNAL OF BIOMECHANICS, 2008, 41 (06) : 1222 - 1228
  • [23] HISTOMORPHOMETRIC BONE ASSESSMENT IN PATIENTS WITH FRACTURE OF THE PROXIMAL END OF THE FEMUR
    De Souza, Caio Goncalves
    Goncalves De Souza, Marcio Passini
    Jorgetti, Vanda
    Dos Reis, Luciene Machado
    ACTA ORTOPEDICA BRASILEIRA, 2015, 23 (02): : 103 - 106
  • [24] MICROSTRUCTURAL CHARACTERISTICS AND REMODELING OF BONE IN THE NECK OF FEMUR AT THE TIME OF FRACTURE
    ZANELLI, JM
    BRADBEER, JN
    MOYES, S
    WAND, JS
    ROUX, JP
    GREEN, JR
    ARLOT, ME
    MEUNIER, PJ
    REEVE, J
    JOURNAL OF BONE AND MINERAL RESEARCH, 1992, 7 : S197 - S197
  • [25] Effects of letrozole on bone biomarkers and femur fracture in female rats
    Yonden, Z.
    Aydin, M.
    Alcin, E.
    Kelestemur, M. H.
    Kutlu, S.
    Yilmaz, B.
    JOURNAL OF PHYSIOLOGY AND BIOCHEMISTRY, 2009, 65 (03) : 267 - 275
  • [26] Effects of letrozole on bone biomarkers and femur fracture in female rats
    Z. Yonden
    M. Aydin
    E. Alcin
    M. H. Kelestemur
    S. Kutlu
    B. Yilmaz
    Journal of Physiology and Biochemistry, 2009, 65 : 267 - 275
  • [27] BONE DENSITY, OSTEOARTHROSIS OF HIP, AND FRACTURE OF UPPER END OF FEMUR
    FOSS, MVL
    BYERS, PD
    ANNALS OF THE RHEUMATIC DISEASES, 1972, 31 (04) : 259 - +
  • [28] Numerical modelling of hip fracture patterns in human femur
    Marco, Miguel
    Giner, Eugenio
    Ramon Caeiro-Rey, Jose
    Henar Miguelez, M.
    Larrainzar-Garijo, Ricardo
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2019, 173 : 67 - 75
  • [29] Influence of microdamage on fracture toughness of the human femur and tibia
    Norman, TL
    Yeni, YN
    Brown, CU
    Wang, Z
    BONE, 1998, 23 (03) : 303 - 306
  • [30] Application of Fibre Bragg Grating Sensors in Strain Monitoring and Fracture Recovery of Human Femur Bone
    Najafzadeh, Ali
    Serandi Gunawardena, Dinusha
    Liu, Zhengyong
    Tran, Ton
    Tam, Hwa-Yaw
    Fu, Jing
    K. Chen, Bernard