Endovascular Aneurysm Repair With AFX Stent-Grafts or Tube Grafts for Sacciform Infrarenal Pathologies in a Narrow Aortic Anatomy

被引:4
|
作者
Lescan, Mario [1 ]
Andic, Mateja [1 ]
Serban, Denisa [1 ]
Artzner, Christoph [2 ]
Grozinger, Gerd [2 ]
Schlensak, Christian [1 ]
Estler, Arne [2 ]
Mustafi, Migdat [1 ]
机构
[1] Univ Med Ctr Tubingen, Dept Thorac & Cardiovasc Surg, Hoppe Seyler Str 3, D-72076 Tubingen, Germany
[2] Univ Med Ctr Tubingen, Dept Radiol, Tubingen, Germany
关键词
endovascular aneurysm repair; abdominal aortic aneurysm; penetrating aortic ulcer; infrarenal; aneurysm neck; bifurcated stent-graft; DISTAL AORTA; ANGIOPLASTY; ENDOGRAFT; ULCERS; EVAR;
D O I
10.1177/15266028221079756
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: The objective of this study was to compare the outcomes of patients treated with tube grafts and AFX stent-graft in the narrow infrarenal aortic anatomy. Materials and Methods: Patients with penetrating aortic ulcers (PAUs) or sacciform aneurysms of the infrarenal aorta and an aortic bifurcation diameter <= 20 mm who underwent endovascular aneurysm repair (EVAR) with bifurcated AFX or tube stent-grafts (TUBE) between 2012 and 2020 were included. Demographic data and the outcome of the AFX group were compared with the TUBE group. All morphological measurements in the preoperative and postoperative computed tomography scans were performed in the aortic centerline. Results: Fifty-one patients (female: 12/51; 29%; median age: 72 years [63, 77]) with a median follow-up of 10 (3, 39) months, were included, of whom 35/51 (69%) had PAUs and 11/51 were symptomatic (22%). The aortic bifurcation diameter was 17 mm (15, 18) with severe calcifications in 25/51 (49%). The distal aortic landing zone was longer in the TUBE group (9 mm vs 24 mm; p<0.001). The technical success was 96% with a median aneurysm shrinkage of 8% (3, 13), which was comparable between the groups (p=0.264). Periprocedural mortality, conversion to open surgery, myocardial infarction, and stroke were not observed. Two type Ia endoleaks (EL) and 2 type Ib EL occurred, all in the TUBE group (Type 1 EL; 19 vs 0%; p=0.013). The limb patency in the AFX group was 100%. One patient with a tube graft developed an infrarenal aortic thrombosis 40 months after the intervention. The reintervention rate in the TUBE group was higher (14 vs 0%; p=0.032) and included 3 aortic cuff implantations and 1 covered endovascular aortic reconstruction of aortic bifurcation (CERAB). Conclusion: AFX stent-graft showed a lower rate of type I endoleaks and reinterventions in sacciform infrarenal aortic pathologies during the early and midterm follow-up.
引用
下载
收藏
页码:185 / 193
页数:9
相关论文
共 50 条
  • [21] Endovascular stent-grafts implantation for descending thoracic aortic dissection and aneurysm
    Shim, WH
    Lee, BK
    Yoon, YS
    Lee, DY
    Chang, BC
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 284A - 285A
  • [22] Endoluminal stent-grafts for infrarenal abdominal aortic aneurysms
    Blum, U
    Voshage, G
    Lammer, J
    Beyersdorf, F
    Tollner, D
    Kretschmer, G
    Spillner, G
    Polterauer, P
    Nagel, G
    Holzenbein, T
    Thurnher, S
    Langer, M
    NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (01): : 13 - 20
  • [23] Comparison of the fixation strength of standard and fenestrated Stent-Grafts for endovascular abdominal aortic aneurysm repair
    Zhou, Samuel S. N.
    How, Thien V.
    Vallabhaneni, S. Rao
    Gilling-Smith, Geoffrey L.
    Brennan, John A.
    Harris, Peter L.
    McWilliams, Richard
    JOURNAL OF ENDOVASCULAR THERAPY, 2007, 14 (02) : 168 - 175
  • [24] Endovascular Treatment of Spontaneous and Isolated Infrarenal Acute Aortic Syndrome with Unibody Aortic Stent-Grafts
    Pecoraro, Felice
    Dinoto, Ettore
    Mirabella, Domenico
    Ferlito, Francesca
    Farina, Arduino
    Pakeliani, David
    Lachat, Mario
    Urso, Francesca
    Bajardi, Guido
    WORLD JOURNAL OF SURGERY, 2020, 44 (12) : 4267 - 4274
  • [25] Endovascular stent-grafts for thoracic aortic disease
    Eggebrecht, H
    Baumgart, D
    Herold, U
    Rasusch, S
    Naber, C
    Haude, M
    Barkhausen, J
    Jakob, H
    Erbel, R
    MATERIALWISSENSCHAFT UND WERKSTOFFTECHNIK, 2002, 33 (12) : 779 - 785
  • [26] Endovascular Treatment of Spontaneous and Isolated Infrarenal Acute Aortic Syndrome with Unibody Aortic Stent-Grafts
    Felice Pecoraro
    Ettore Dinoto
    Domenico Mirabella
    Francesca Ferlito
    Arduino Farina
    David Pakeliani
    Mario Lachat
    Francesca Urso
    Guido Bajardi
    World Journal of Surgery, 2020, 44 : 4267 - 4274
  • [27] Explant of aortic stent grafts following endovascular aneurysm repair
    Lynch, M.
    McGuire, D.
    McHugh, S. M.
    Ahmed, Z.
    El-Mallah, A.
    Amin, A.
    Hamada, N.
    Colgan, M. P.
    O'Neill, S.
    O'Callaghan, A.
    Martin, Z.
    Madhavan, P.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2015, 184 : S160 - S160
  • [28] Explant of aortic stent grafts following endovascular aneurysm repair
    Boyle, E.
    McHugh, S. M.
    Elmallah, A.
    Lynch, M.
    McGuire, D.
    Ahmed, Z.
    Canning, C.
    Colgan, M. P.
    O'Neill, S. M.
    O'Callaghan, A.
    Martin, Z.
    Madhavan, P.
    VASCULAR, 2019, 27 (05) : 487 - 494
  • [29] Limitations of Endovascular Treatment with Stent-Grafts for Active Mycotic Thoracic Aortic Aneurysm
    Masaki Ishida
    Noriyuki Kato
    Tadanori Hirano
    Takatsugu Shimono
    Fuyuhiko Yasuda
    Kuniyoshi Tanaka
    Isao Yada
    Kan Takeda
    CardioVascular and Interventional Radiology, 2002, 25 : 216 - 218
  • [30] BIFURCATED STENT-GRAFTS FOR ENDOVASCULAR REPAIR OF ABDOMINAL AORTIC-ANEURYSM - PRELIMINARY CASE-REPORTS
    CHUTER, TAM
    DONAYRE, C
    WENDT, G
    SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1994, 8 (07): : 800 - 802