Comparison of the fixation strength of standard and fenestrated Stent-Grafts for endovascular abdominal aortic aneurysm repair

被引:2
|
作者
Zhou, Samuel S. N.
How, Thien V. [1 ]
Vallabhaneni, S. Rao
Gilling-Smith, Geoffrey L.
Brennan, John A.
Harris, Peter L.
McWilliams, Richard
机构
[1] Univ Liverpool, Div Clin Engn, Sch Clin Sci, Liverpool L69 3GA, Merseyside, England
[2] Royal Liverpool Univ Hosp, Dept Vasc Surg, Liverpool, Merseyside, England
[3] Royal Liverpool Univ Hosp, Dept Radiol, Liverpool, Merseyside, England
关键词
abdominal aortic aneurysm; endovascular repair; stent-graft; fenestrated stent-graft; bovine aorta; displacement force; migration;
D O I
10.1583/1545-1550(2007)14[168:COTFSO]2.0.CO;2
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To determine whether fenestrated stent-grafts provide better stability to resist migration than standard non-fenestrated stent-grafts. Methods: Truncated fenestrated stent-grafts with a single fenestration were deployed in bovine aortic segments with a side branch. Balloon-expandable stents were then delivered into the branches. Similarly, standard stent-grafts of the same dimensions were deployed for comparison. The aorta was pressurized to achieve stent-graft oversizing of 5%, 10%, or 20%. The force required to cause distal migration was recorded by a digital force gauge attached to the stent-graft. Results: Displacement of the stent-grafts occurred in 2 distinct phases: an initial yield during which the barbs embedded in the aortic wall and a final displacement leading to significant migration and dislodgement of the device. The displacement force that initiated each phase was dependent upon the degree of oversizing of the stent-graft relative to the aortic diameter. For 5%, 10%, and 20% oversizing, the mean displacement forces in the initial displacement phase were 3.39 +/- 0.37, 4.32 +/- 0.63, and 7.69 +/- l.18 N, respectively, in non-fenestrated grafts and 10.48 +/- 1.23, 11.45 +/- 1.48, 12.12 +/- 1.42 N in fenestrated grafts. The displacement forces in the final displacement phase were 8.10 +/- 0.92, 10.76 +/- 1.74, and 16.82 +/- 0.92 N for non-fenestrated and 22.56 +/- 1.60, 28.24 +/- 1.56, and 33.01 +/- 1.75 N for fenestrated stent-grafts. The differences in displacement forces between standard and fenestrated stent-grafts were significant for both phases (p<0.001) at all oversizing levels. Conclusion: Improvement in fixation strength was noted with increasing stent-graft oversizing of up to 20%. Fenestrated stent-grafts offer higher ultimate fixation compared to standard devices. However, the ultimate fixation strength was not recruited until an initial phase of short migration occurred as the barbs engaged. While this movement is inconsequential with standard stent-grafts, it has the potential to crush the stents placed into aortic side branches with fenestrated endografts.
引用
收藏
页码:168 / 175
页数:8
相关论文
共 50 条
  • [1] Fenestrated Stent-Grafts for Salvage of Prior Endovascular Abdominal Aortic Aneurysm Repair
    Katsargyris, A.
    Yazar, O.
    Oikonomou, K.
    Bekkema, F.
    Tielliu, I.
    Verhoeven, E. L. G.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2013, 46 (01) : 49 - 56
  • [2] Comparison of Blood Flow in Branched and Fenestrated Stent-Grafts for Endovascular Repair of Abdominal Aortic Aneurysms
    Kandail, Harkamaljot
    Hamady, Mohamad
    Xu, Xiao Yun
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2015, 22 (04) : 578 - 590
  • [3] Salvage of failed prior endovascular abdominal aortic aneurysm repair with fenestrated endovascular stent grafts
    Adam, Donald J.
    Fitridge, Robert A.
    Berce, Michael
    Hartley, David E.
    Anderson, John L.
    [J]. JOURNAL OF VASCULAR SURGERY, 2006, 44 (06) : 1341 - 1344
  • [4] Rescue of proximal failure of endovascular abdominal aortic aneurysm repair with standard and fenestrated grafts
    Marques De Marino, Pablo
    Malgor, Rafael D.
    Verhoeven, Eric L.
    Katsargyris, Athanasios
    [J]. JOURNAL OF CARDIOVASCULAR SURGERY, 2019, 60 (02): : 159 - 166
  • [5] Homemade Fenestrated Stent-Grafts for Complete Endovascular Repair of Aortic Arch Dissections
    Canaud, Ludovic
    Ozdemir, Baris Ata
    Chassin-Trubert, Lucien
    Sfeir, Julien
    Alric, Pierre
    Gandet, Thomas
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2019, 26 (05) : 645 - 651
  • [6] Fenestrated and branched stent-grafts for thoracoabdominal, pararenal and juxtarenal aortic aneurysm repair
    Chuter, Timothy A. M.
    [J]. SEMINARS IN VASCULAR SURGERY, 2007, 20 (02) : 90 - 96
  • [7] Comparison of Endovascular Stent Grafts for Abdominal Aortic Aneurysm Repair in Medicare Patients
    Buck, Dominique B.
    Landon, Bruce E.
    O'Malley, Alistair J.
    Zettervall, Sara L.
    Soden, Peter A.
    Zaborski, Lawrence B.
    Ultee, Klaas H.
    Schermerhorn, Marc L.
    [J]. JOURNAL OF VASCULAR SURGERY, 2015, 61 (06) : 84S - 84S
  • [8] Comparison of Endovascular Stent Grafts for Abdominal Aortic Aneurysm Repair in Medicare Beneficiaries
    Buck, Dominique B.
    Soden, Peter A.
    Deery, Sarah E.
    Zettervall, Sara L.
    Ultee, Klaas H. J.
    Landon, Bruce E.
    O'Malley, A. James
    Schermerhorn, Marc L.
    [J]. ANNALS OF VASCULAR SURGERY, 2018, 47 : 31 - 42
  • [9] Endovascular abdominal aortic aneurysm repair and renal complications: a comparison between suprarenal and infrarenal fixation of stent grafts
    Cotroneo, A. R.
    Iezzi, R.
    Giancristofaro, D.
    Santoro, M.
    Pierro, A.
    Spigonardo, F.
    Storto, M. L.
    [J]. RADIOLOGIA MEDICA, 2007, 112 (02): : 252 - 263
  • [10] Transrenal fixation of endovascular stent-grafts for infrarenal aortic aneurysm repair: Mid-term results
    Bove, PG
    Long, GW
    Shanley, CJ
    Brown, OW
    Rimar, SD
    Hans, SS
    Kitzmiller, JW
    Bendick, PJ
    Zelenock, GB
    [J]. JOURNAL OF VASCULAR SURGERY, 2003, 37 (05) : 938 - 942