Application of Disposable Pipette Extraction for Determination of Yb by High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry Using Lanthanum as a Chemical Modifier

被引:0
|
作者
Betiolo, Diogo M. [1 ]
Cadorim, Heloisa R. [1 ]
Carasek, Eduardo [1 ]
Maranhao, Tatiane A. [1 ]
机构
[1] Univ Fed Santa Catarina, Dept Quim, BR-88040900 Florianopolis, SC, Brazil
关键词
ytterbium; residual water; environmental samples; sample preparation; DPX HR-CS GF AAS; RARE-EARTH-ELEMENTS; WATER SAMPLES; VAPORIZATION; OPTIMIZATION; CATALYST; DESIGN;
D O I
10.21577/0103-5053.20230021
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The use of extraction technique with disposable tips (DPX) was applied for the first time for the extraction and preconcentration of Yb in samples of liquid waste from the petrochemical industry and environmental water using bioabsorbent cork. The use of cork as an extracting phase in the determination of Yb by high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GF AAS) was evaluated. The pyrolysis and atomization temperatures were optimized at 1400 and 2400 degrees C, respectively. H2SO4, HNO3 and HCl acids were compared in the steps of cleaning the extraction phase and desorption of the analyte by DPX. The best extraction in the selected conditions was obtained with pH 8.0 and 5% v/v HCl. The recoveries were close to 100% for residual water and drinking water, 33 to 77% for produced water and 64 to 93% for river water. Tests with interfering ions in different concentrations were performed. The relative limit of quantification (LOQ) and limit of detection (LOD) were estimated at 0.03 and 0.01 mu g L-1, respectively. The total time for the preparation of the samples by DPX was close to 1 min per sample. Extraction and pre-concentration were observed using DPX with a preenrichment factor of approximately 4 times.
引用
收藏
页码:1087 / 1099
页数:13
相关论文
共 50 条
  • [41] Determination of Pb and Cr in sunscreen samples by high-resolution continuum source graphite furnace atomic absorption spectrometry and direct analysis
    Zmozinski, Ariane V.
    Pretto, Tatiane
    Borges, Aline R.
    Duarte, Alvaro T.
    Vale, Maria Goreti R.
    MICROCHEMICAL JOURNAL, 2016, 128 : 89 - 94
  • [42] Determination of residual dimethyl sulfoxide by high-resolution continuum source graphite furnace molecular absorption spectrometry
    Huang, Mao Dong
    Esser, Norbert
    Hinrichs, Karsten
    Tan, Qin
    Rappich, Jorg
    Nickel, Norbert H.
    Dittrich, Thomas
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2021, 177
  • [43] Determination of silicon in plant materials using direct solid sample analysis with high-resolution continuum source graphite furnace atomic absorption spectrometry
    Boschetti, Wiliam
    Dalagnol, Luiza M. G.
    Dullius, Mariana
    Zmozinski, Ariane V.
    Becker, Emilene M.
    Vale, Maria Goreti R.
    de Andrade, Jailson B.
    MICROCHEMICAL JOURNAL, 2016, 124 : 380 - 385
  • [44] Sequential and simultaneous determination of four elements in soil samples using high-resolution continuum source graphite furnace atomic and molecular absorption spectrometry
    Boschetti, W.
    Orlando, M.
    Dullius, M.
    Dessuy, M. B.
    Vale, M. G. R.
    Welz, B.
    de Andrade, J. B.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (06) : 1269 - 1277
  • [45] Investigation of spectral interferences in the determination of lead in fertilizers and limestone samples using high-resolution continuum source graphite furnace atomic absorption spectrometry
    Borges, Aline R.
    Becker, Emilene M.
    Francois, Luciane L.
    de Jesus, Alexandre
    Vale, Maria Goreti R.
    Welz, Bernhard
    Dessuy, Morgana B.
    de Andrade, Jailson B.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2014, 101 : 213 - 219
  • [46] Method development for the determination of cadmium in fertilizer samples using high-resolution continuum source graphite furnace atomic absorption spectrometry and slurry sampling
    Borges, Aline R.
    Becker, Emilene M.
    Lequeux, Celine
    Vale, Maria Goreti R.
    Ferreira, Sergio L. C.
    Welz, Bernhard
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (07) : 529 - 535
  • [47] Determination of chromium and antimony in polymers from electrical and electronic equipment using high-resolution continuum source graphite furnace atomic absorption spectrometry
    Duarte, Alvaro T.
    Dessuy, Morgana B.
    Vale, Maria Goreti R.
    Welz, Bernhard
    ANALYTICAL METHODS, 2013, 5 (24) : 6941 - 6946
  • [48] Determination of selenium in soil samples using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sample analysis
    Castilho, Ivan N. B.
    Pereira, Ederson R.
    Welz, Bernhard
    Shaltout, Abdallah A.
    Caraseka, Eduardo
    Martensd, Irland B. Gonzaga
    ANALYTICAL METHODS, 2014, 6 (09) : 2870 - 2875
  • [49] Determination of Pb, Cd and Cr in Food by High Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry
    Ren Ting
    Zhao Li-jiao
    Cao Jun
    Zhong Ru-gang
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32 (09) : 2566 - 2571
  • [50] Determination of boron isotope ratios by high-resolution continuum source molecular absorption spectrometry using graphite furnace vaporizers
    Abad, Carlos
    Florek, Stefan
    Becker-Ross, Helmut
    Huang, Mao-Dong
    Heinrich, Hans-Joachim
    Recknagel, Sebastian
    Vogl, Jochen
    Jakubowski, Norbert
    Panne, Ulrich
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2017, 136 : 116 - 122