Ultra-low-dose CBCT: new cornerstone of paranasal sinus imaging

被引:3
|
作者
Tamminen, Pekka [1 ,2 ,3 ,5 ,6 ]
Jarnstedt, Jorma [4 ]
Numminen, Jura [1 ]
Lehtinen, Antti [4 ]
Lehtimaki, Lauri [5 ,6 ]
Rautiainen, Markus [1 ,6 ]
Kivekas, Ilkka [1 ,6 ]
机构
[1] Tampere Univ Hosp, Dept Otorhinolaryngol Head & Neck Surg, Tampere, Finland
[2] Satasairaala, Dept Otorhinolaryngol, Pori, Finland
[3] Tampere Univ Hosp, Dept Internal Med, Tampere, Finland
[4] Tampere Univ Hosp, Med Imaging Ctr, Dept Radiol, Tampere, Finland
[5] Tampere Univ Hosp, Allergy Ctr, Tampere, Finland
[6] Tampere Univ, Fac Med & Hlth Technol, Tampere, Finland
关键词
Cone beam computed tomography (CBCT); paranasal sinuses; sinusitis; radiation dosage; nasal surgical procedures; BEAM COMPUTED-TOMOGRAPHY; CT; MULTIDETECTOR; HEAD; RISK;
D O I
10.4193/Rhin22.385
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Background: This study evaluates the clinical image quality (IQ) and usability of a sinonasal ultra-low-dose (ULD) cone-beam computed tomography (CBCT) scan. The results are compared to those of a high resolution (HR) CBCT scan to identify the streng-ths and weaknesses of a ULD CBCT protocol.Methodology: Sixty-six anatomical sites in 33 subjects were imaged twice using two imaging modalities: HR CBCT (Scanora 3Dx scanner; Soredex, Tuusula, Finland) and ULD CBCT (Promax 3D Mid scanner; Plandent, Helsinki, Finland). IQ, opacification and obstruction, structural features and operative usability were assessed.Results: The overall IQ in subjects with "no or minor opacification" was excellent: 100% (HR CBCT) and 99% (ULD CBCT) of ratings were evaluated as sufficient for every structure. Increased opacification reduced the quality of both imaging modalities, resulting in sufficient IQ in 97% (HR CBCT) and 92% (ULD CBCT) of evaluations. With greater opacification, the sufficient-insufficient ratio was better (p< 0.05) for HR CBCT regarding the anterior ethmoidal artery, lateral lamella, frontal recess, cribriform plate, superior concha and posterior ethmoidal artery. ULD CBCT's operative applicability was generally good with moderate restraints in fron-toethmoidectomy, frontal sinusotomy, sphenotomy and posterior ethmoidectomy in cases with greater opacification.Conclusions: IQ of paranasal ULD CBCT is sufficient for clinical diagnostics and should be considered for surgical planning. We recommend it as the primary imaging protocol for all patients who meet imaging criteria due to recurrent or chronic nasal symptoms. Additional or conventional imaging might be needed for patients with extensive chronic rhinosinusitis and/or indicati-ons of frontal sinus involvement.
引用
收藏
页码:221 / 230
页数:10
相关论文
共 50 条
  • [41] Endometrial Safety of Ultra-Low-Dose Estradiol Vaginal Tablets
    Simon, James
    Nachtigall, Lila
    Ulrich, Lian G.
    Eugster-Hausmann, Michaela
    Gut, Robert
    OBSTETRICS AND GYNECOLOGY, 2010, 116 (04): : 876 - 883
  • [42] Evaluation of ultra-low-dose CT with tin filter for craniosynostosis
    Tao, Wilson
    Goetti, Robert
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2025, 69 (01) : 28 - 34
  • [43] Safety of coronary stenting with Eptifibatide and ultra-low-dose heparin
    Le May, M
    Kurdi, M
    Labinaz, M
    Glover, C
    So, D
    Ryan, S
    Davies, R
    AMERICAN JOURNAL OF CARDIOLOGY, 2005, 95 (05): : 630 - 632
  • [44] Accuracy of cardiac PET with ultra-low-dose CT/AC
    Hamill, James
    Eisner, Robert
    Streeter, James
    Patterson, Randolph
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [45] Osteoporosis prevention with unopposed ultra-low-dose transdermal estradiol
    Ettinger, B
    Grady, D
    Foegh, M
    Hanes, V
    OBSTETRICS AND GYNECOLOGY, 2004, 103 (04): : 6S - 6S
  • [46] Ultra-low-dose ketamine infusion for ischemic limb pain
    Qutaiba A. Tawfic
    Naveen Eipe
    John Penning
    Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2014, 61 : 86 - 87
  • [47] Patient Effective Dose for Ultra-Low-Dose CT Hip Imaging with Tin Filtration Vs X-Ray
    Chu, R.
    Tsai, A.
    Callahan, M. J.
    Kim, D. S.
    Beaulieu, D. R.
    Chong, S. H.
    Zhang, D.
    MEDICAL PHYSICS, 2024, 51 (10) : 7775 - 7776
  • [48] URO - low-dose vs. ultra-low-dose CT in the diagnosis of urolithiasis
    Graewert, Stephanie
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2024, 196 (01): : 18 - 19
  • [49] Investigating Simultaneity for Deep Learning?Enhanced Actual Ultra-Low-Dose Amyloid PET/MR Imaging
    Chen, K. T.
    Adeyeri, O.
    Toueg, T. N.
    Zeineh, M.
    Mormino, E.
    Khalighi, M.
    Zaharchuk, G.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2022, 43 (03) : 354 - 360
  • [50] Evaluating the Safety of Ultra-Low-Dose Estrogen Contraception in Sickle Cell Trait With Focus on Cerebral Venous Sinus Thrombosis
    Kahn, Cameron
    Rathore, Azeem
    Kronen, Tara
    Fahad, Ameen
    Crooks, Ryan
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (01)