Ultra-low-dose CBCT: new cornerstone of paranasal sinus imaging

被引:3
|
作者
Tamminen, Pekka [1 ,2 ,3 ,5 ,6 ]
Jarnstedt, Jorma [4 ]
Numminen, Jura [1 ]
Lehtinen, Antti [4 ]
Lehtimaki, Lauri [5 ,6 ]
Rautiainen, Markus [1 ,6 ]
Kivekas, Ilkka [1 ,6 ]
机构
[1] Tampere Univ Hosp, Dept Otorhinolaryngol Head & Neck Surg, Tampere, Finland
[2] Satasairaala, Dept Otorhinolaryngol, Pori, Finland
[3] Tampere Univ Hosp, Dept Internal Med, Tampere, Finland
[4] Tampere Univ Hosp, Med Imaging Ctr, Dept Radiol, Tampere, Finland
[5] Tampere Univ Hosp, Allergy Ctr, Tampere, Finland
[6] Tampere Univ, Fac Med & Hlth Technol, Tampere, Finland
关键词
Cone beam computed tomography (CBCT); paranasal sinuses; sinusitis; radiation dosage; nasal surgical procedures; BEAM COMPUTED-TOMOGRAPHY; CT; MULTIDETECTOR; HEAD; RISK;
D O I
10.4193/Rhin22.385
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Background: This study evaluates the clinical image quality (IQ) and usability of a sinonasal ultra-low-dose (ULD) cone-beam computed tomography (CBCT) scan. The results are compared to those of a high resolution (HR) CBCT scan to identify the streng-ths and weaknesses of a ULD CBCT protocol.Methodology: Sixty-six anatomical sites in 33 subjects were imaged twice using two imaging modalities: HR CBCT (Scanora 3Dx scanner; Soredex, Tuusula, Finland) and ULD CBCT (Promax 3D Mid scanner; Plandent, Helsinki, Finland). IQ, opacification and obstruction, structural features and operative usability were assessed.Results: The overall IQ in subjects with "no or minor opacification" was excellent: 100% (HR CBCT) and 99% (ULD CBCT) of ratings were evaluated as sufficient for every structure. Increased opacification reduced the quality of both imaging modalities, resulting in sufficient IQ in 97% (HR CBCT) and 92% (ULD CBCT) of evaluations. With greater opacification, the sufficient-insufficient ratio was better (p< 0.05) for HR CBCT regarding the anterior ethmoidal artery, lateral lamella, frontal recess, cribriform plate, superior concha and posterior ethmoidal artery. ULD CBCT's operative applicability was generally good with moderate restraints in fron-toethmoidectomy, frontal sinusotomy, sphenotomy and posterior ethmoidectomy in cases with greater opacification.Conclusions: IQ of paranasal ULD CBCT is sufficient for clinical diagnostics and should be considered for surgical planning. We recommend it as the primary imaging protocol for all patients who meet imaging criteria due to recurrent or chronic nasal symptoms. Additional or conventional imaging might be needed for patients with extensive chronic rhinosinusitis and/or indicati-ons of frontal sinus involvement.
引用
收藏
页码:221 / 230
页数:10
相关论文
共 50 条
  • [31] Morphological concordance between CBCT and MDCT: a paranasal sinus-imaging anatomical study
    Demeslay, J.
    Vergez, S.
    Serrano, E.
    Chaynes, P.
    Cantet, P.
    Chaput, B.
    de Bonnecaze, G.
    SURGICAL AND RADIOLOGIC ANATOMY, 2016, 38 (01) : 71 - 78
  • [32] Diagnostic accuracy of oncologic ultra-low-dose FDG-PET imaging: a pilot study
    Niederkohr, Ryan
    Hamill, James
    Jones, Judson
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [33] THE EFFECT OF ULTRA-LOW-DOSE HEPARIN IN EXPERIMENTAL VENOUS THROMBOSIS
    HLADOVEC, J
    THROMBOSIS RESEARCH, 1984, 36 (01) : 83 - 85
  • [34] Ultra-Low-Dose Contrast Using Transluminal Renal Angioplasty: The ULTRA Study
    Kawano, Megumi
    Suzuki, Kenji
    Fujimura, Naoki
    Endo, Ayaka
    Kato, Ai
    Fujii, Kentaro
    Komatsu, Motoaki
    Takahashi, Toshiyuki
    Ryuzaki, Munekazu
    Harada, Hirohisa
    VASCULAR AND ENDOVASCULAR SURGERY, 2023, 57 (04) : 324 - 330
  • [35] Cost Savings and Increased Access With Ultra-Low-Dose Immunotherapy
    Mitchell, Aaron P.
    Goldstein, Daniel A.
    JOURNAL OF CLINICAL ONCOLOGY, 2023, 41 (02) : 170 - +
  • [36] Efficacy and safety of ultra-low-dose Vagifem (10 mcg)
    Chollet, Janet A.
    PATIENT PREFERENCE AND ADHERENCE, 2011, 5 : 571 - 574
  • [37] Ultra-low-dose ketamine infusion for ischemic limb pain
    Tawfic, Qutaiba A.
    Eipe, Naveen
    Penning, John
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2014, 61 (01): : 86 - 87
  • [38] Ultra-low-dose spiral CT in the lung: Filtering technique
    Nitta, N
    Takahashi, M
    Murata, K
    Mori, M
    Morita, R
    RADIOLOGY, 1996, 201 : 380 - 380
  • [39] Optimization of paranasal sinus CT procedure: Ultra-low dose CT as a roadmap for pre-functional endoscopic sinus surgery
    Diklic, Ana
    Zujic, Petra Valkovic
    Segota, Doris
    Debeljuh, Dea Dundara
    Jurkovic, Slaven
    Brambilla, Marco
    Kalra, Mannudeep K.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 78 : 195 - 200
  • [40] Ultra-low-dose oral contraceptives: Are they right for your patient?
    Thorneycroft, IH
    MEDSCAPE WOMENS HEALTH, 2001, 6 (04):