Methods for Enhancing the Robustness of the Generalized Contrast-to-Noise Ratio

被引:4
|
作者
Schlunk, Siegfried [1 ]
Byram, Brett C. [1 ]
机构
[1] Vanderbilt Univ, Dept Biomed Engn, Nashville, TN 37232 USA
关键词
Histograms; image analysis; image quality; nonparametric statistics; probability density function (PDF); ranking; ultrasonic imaging; 1ST-ORDER STATISTICS; MODEL; DETECTABILITY; BACKSCATTER; COHERENCE;
D O I
10.1109/TUFFC.2023.3289157
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The generalized contrast-to-noise ratio (gCNR) is a new but increasingly popular metric for measuring lesion detectability due to its use of probability distribution functions that increase robustness against transformations and dynamic range alterations. The value of these kinds of metrics has become increasingly important as it becomes clear that traditional metrics can be arbitrarily boosted with advanced beamforming or the right kinds of postprocessing. The gCNR works well for most cases; however, we will demonstrate that for some specific cases the implementation of gCNR using histograms requires careful consideration, as histograms can be poor estimates of probability density functions (PDFs) when designed improperly. This is demonstrated with simulated lesions by altering the amount of data and the number of bins used in the calculation, as well as by introducing some extreme transformations that are represented poorly by uniformly spaced histograms. In this work, the viability of a parametric gCNR implementation is tested, more robust methods for implementing histograms are considered, and a new method for estimating gCNR using empirical cumulative distribution functions (eCDFs) is shown. The most consistent methods found were to use histograms on rank-ordered data or histograms with variable bin widths, or to use eCDFs to estimate the gCNR.
引用
下载
收藏
页码:831 / 842
页数:12
相关论文
共 50 条
  • [21] Contrast-to-noise ratio optimization for a prototype phase-contrast computed tomography scanner
    Mueller, Mark
    Yaroshenko, Andre
    Velroyen, Astrid
    Bech, Martin
    Tapfer, Arne
    Pauwels, Bart
    Bruyndonckx, Peter
    Sasov, Alexander
    Pfeiffer, Franz
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (12):
  • [22] Blind Estimation for Localized Low Contrast-to-Noise Ratio BOLD Signals
    Atkinson, Ian C.
    Kamalabadi, Farzad
    Jones, Douglas L.
    Thulborn, Keith R.
    IEEE JOURNAL OF SELECTED TOPICS IN SIGNAL PROCESSING, 2008, 2 (06) : 879 - 890
  • [23] The Contrast-to-Noise Ratio for Image Quality Evaluation in Scanning Electron Microscopy
    Timischl, F.
    SCANNING, 2015, 37 (01) : 54 - 62
  • [24] Signal-to-noise ratio, contrast-to-noise ratio, and exposure time for imaging systems with photon-limited noise
    Lucke, Robert L.
    Kessel, Robert A.
    OPTICAL ENGINEERING, 2006, 45 (05)
  • [25] Signal-to-noise ratio, contrast-to-noise ratio and pharmacokinetic modeling considerations in dynamic contrast-enhanced magnetic resonance imaging
    Li, Xin
    Huang, Wei
    Rooney, William D.
    MAGNETIC RESONANCE IMAGING, 2012, 30 (09) : 1313 - 1322
  • [26] Quantifying image quality in chest computed tomography angiography: Evaluation of different contrast-to-noise ratio measurement methods
    Chatzaraki, Vasiliki
    Kubik-Huch, Rahel A.
    Thali, Michael
    Niemann, Tilo
    ACTA RADIOLOGICA, 2022, 63 (10) : 1353 - 1362
  • [27] Effect of kVp on Noise, Dose, and Contrast-to-Noise Ratio for Pediatric Low-Dose CT
    Gamberoni, J.
    Dong, F.
    Davros, B.
    Reid, J.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)
  • [28] Improvements in elastographic contrast-to-noise ratio using spatial-angular compounding
    Techavipoo, U
    Varghese, T
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (04): : 529 - 536
  • [29] Evaluation of both image resolution and contrast-to-noise ratio in scanning electron microscopy
    Ishitani, Tohru
    Sato, Mitsugu
    JOURNAL OF ELECTRON MICROSCOPY, 2007, 56 (04) : 145 - 151
  • [30] A novel method for contrast-to-noise ratio (CNR) evaluation of digital mammography detectors
    Baldelli, P.
    Phelan, N.
    Egan, G.
    EUROPEAN RADIOLOGY, 2009, 19 (09) : 2275 - 2285