Dynamic response analyses of long-span cable-stayed bridges subjected to pulse-type ground motions

被引:18
|
作者
Jia, Hongyu [1 ]
Liu, Zhi [2 ]
Xu, Li [2 ]
Bai, Hao [3 ]
Bi, Kaiming [4 ]
Zhang, Chao [2 ]
Zheng, Shixiong [1 ]
机构
[1] Southwest Jiaotong Univ, Sch Civil Engn, Chengdu 610031, Peoples R China
[2] Fuzhou Univ, Coll Civil Engn, Fuzhou 350116, Peoples R China
[3] Sichuan Expressway Construct & Dev Grp Co Ltd, Chengdu 610041, Peoples R China
[4] Curtin Univ, Ctr Infrastruct Monitoring & Protect, Sch Civil Engn & Mech, Kent St, Bentley, WA 6102, Australia
基金
美国国家科学基金会;
关键词
Long-span cable-stayed bridge; Pulse-type ground motion; Shaking table test; Seismic response; Structure analysis; 1988 SAGUENAY EARTHQUAKE; NEAR-FAULT; DAMAGE; DIRECTIVITY; BUILDINGS; BEHAVIOR; SPECTRA; MODEL;
D O I
10.1016/j.soildyn.2022.107591
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
This paper presents the dynamic response analyses of a special long-span cable-stayed bridge with the main span length of 680 (m) subjected to pulse-type ground motions. The 1/100 scaled shaking table test are developed herein to verify the accuracy and correctness of the 3D finite element (FE) model of the examined long-span cable-stayed bridge on the software platform of SAP2000. To systematically investigate the influence on the seismic responses and on the selection of the nonlinear viscous damper parameters of the employed long-span cable-stayed bridge both the near-fault pulse-type ground motions and the far-field ground motions are selected as the seismic inputs of FE model. Some important conclusions are drawn that the near-fault ground motions usually causes the larger peak responses (e.g., Tower top displacement, girder end displacement, and moment of tower bottom) of the long-span cable-stayed bridge compared with the far-field motions, namely the near-fault ground motions are more destructive to the structures. The displacement responses can be amplified approximately 2-3 times and the damper parameters (Damping coefficient C and damping index alpha) of nonlinear viscous dampers can be affected by the ground motion characteristics. The damper parameter values are changed from the C = 3000 and alpha = 0.3 in far-field earthquakes to the C = 6000 and alpha = 0.2 in near-fault earthquakes, namely the near-fault ground motions obviously increase the demand of energy consumption of general nonlinear viscous dampers.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Vertical dynamic response of the ballastless track on long-span plate-truss cable-stayed bridges
    Li YongLe
    Su Yang
    Xia FeiLong
    Zhang Nan
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2015, 58 (02) : 236 - 247
  • [22] Vertical dynamic response of the ballastless track on long-span plate-truss cable-stayed bridges
    LI Yong Le
    SU Yang
    XIA Fei Long
    ZHANG Nan
    Science China(Technological Sciences), 2015, 58 (02) : 236 - 247
  • [23] The cable force determination and optimization of the long-span concrete cable-stayed bridges
    Yang, Mei-Liang
    Li, Chuan-Xi
    Zhang, Jian-Ren
    STRUCTURAL CONDITION ASSESSMENT, MONITORING AND IMPROVEMENT, VOLS 1 AND 2, 2007, : 690 - 695
  • [24] Temperature effects on modal frequencies of long-span cable-stayed bridges
    Sun, L.
    Zhou, Y.
    Xie, D.
    LIFE-CYCLE OF STRUCTURAL SYSTEMS: DESIGN, ASSESSMENT, MAINTENANCE AND MANAGEMENT, 2015, : 1091 - 1097
  • [25] Damping properties of FRP cables for long-span cable-stayed bridges
    Yaqiang Yang
    Xin Wang
    Zhishen Wu
    Changhai Peng
    Materials and Structures, 2016, 49 : 2701 - 2713
  • [26] Integrated finite strip analysis for long-span cable-stayed bridges
    Naderian, Hamidreza
    Cheung, Moe M. S.
    Shen, Zhenyuan
    Dragomirescu, Elena
    COMPUTERS & STRUCTURES, 2015, 158 : 82 - 97
  • [27] Investigation of seismic performance of super long-span cable-stayed bridges
    Zhang, Xin-Jun
    Zhao, Chen-Yang
    Guo, Jian
    EARTHQUAKES AND STRUCTURES, 2018, 14 (06) : 493 - 503
  • [28] Aerostatic stability of long-span cable-stayed bridges: Parametric study
    Cheng, Jin
    Jiang, Jianjing
    Xiao, Rucheng
    Xiang, Haifan
    Tsinghua Science and Technology, 2003, 8 (02) : 201 - 205
  • [29] Aerostatic Stability of Long-Span Cable-Stayed Bridges: Parametric Study
    程进
    江见鲸
    肖汝诚
    项海帆
    Tsinghua Science and Technology, 2003, (02) : 201 - 205
  • [30] Damping properties of FRP cables for long-span cable-stayed bridges
    Yang, Yaqiang
    Wang, Xin
    Wu, Zhishen
    Peng, Changhai
    MATERIALS AND STRUCTURES, 2016, 49 (07) : 2701 - 2713