Accelerated Measurement of Carotid Plaque Volume Using Artificial Intelligence Enhanced 3D Ultrasound

被引:0
|
作者
Phair, Alison Shirley [1 ,2 ]
Carreira, Joao [3 ]
Bowling, Frank Lee [1 ,2 ]
Ghosh, Jonathan [1 ,2 ]
Smith, Craig [4 ,5 ]
Rogers, Steven Kristofor [1 ,2 ,6 ]
机构
[1] Univ Manchester, Manchester Univ NHS Fdn Trust, Div Cardiovasc Sci, Manchester Acad Hlth Sci, Manchester, England
[2] Manchester Univ NHS Fdn Trust, Manchester Vasc Ctr, Manchester Acad Vasc Res & Innovat Ctr MAVRIC, Manchester, England
[3] Manchester Univ NHS Fdn Trust, Independent Vasc Serv Ltd, Wythenshawe Hosp, Manchester Acad Hlth Sci Ctr, Manchester, England
[4] Univ Manchester, Lydia Becker Inst Immunol & Inflammat, Div Cardiovasc Sci, Manchester, England
[5] Salford Royal Fdn Trust, Manchester Ctr Clin Neurosci, Geoffrey Jefferson Brain Res Ctr, Manchester Acad Hlth Sci Ctr, Manchester, England
[6] Manchester Univ NHS Fdn Trust, Vasc Studies Unit, Southmoor Rd, Manchester M23 9LT, England
关键词
D O I
10.1016/j.avsg.2023.06.018
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Carotid plaque volume (CPV) can be measured by 3D ultrasound and may be a better predictor of stroke than stenosis, but analysis time limits clinical utility. This study tested the accuracy, reproducibility, and time saved of using an artificial intelligence (AI) derived semiautomatic software to measure CPV ("auto-CPV").Methods: Three-dimensional (3D) ultrasound images for 121 individuals were analyzed by 2 blinded operators to measure auto-CPV. Corresponding endarterectomy specimen volumes were calculated by the validated saline suspension technique. Inter-rater and intrarater agreement plus accuracy compared with the volume of the endarterectomized plaque were calculated. Measurement times were compared with previous manual CPV measurement.Results: The mean difference between auto-CPV and surgical volume was small at (+/- s.d.) [95% confidence interval [CI]] 0.06 (0.24) [-0.41 to 0.54] cm(3). The intraclass correlation (ICC) was strong at 0.91; 95% CI 0.86-0.94. Interobserver and intraobserver error was low with mean difference (+/- s.d.) [95%CI] 0.01 (0.26) [-0.5 to 0.5] cm(3) and 0.03 (0.19) [-0.35 to 0.40] cm(3) respectively. Both showed excellent ICC with narrow confidence intervals, ICC = 0.90; 95% CI (0.85-0.94) and ICC = 0.95; 95% CI (0.92-0.96). Auto-CPV measurement took 43% the time of manual planimetry; median (IQR) 05:39 (01:58) minutes compared to 13:05 (04:15) minutes, Wilcoxon rank-sum test, P < 0.01.Conclusions: Auto-CPV assessment is accurate, reproducible, and significantly faster than manual planimetry. Improved feasibility means that the utility of CPV can be assessed in large population studies to stratify risk in asymptomatic carotid disease or assess response to medical treatment.
引用
收藏
页码:317 / 324
页数:8
相关论文
共 50 条
  • [31] Freehand 3D ultrasound without voxels: volume measurement and visualisation using the Stradx system
    Prager, R
    Gee, A
    Treece, G
    Berman, L
    ULTRASONICS, 2002, 40 (1-8) : 109 - 115
  • [32] A Study 3D Shape Recognition Using Artificial Intelligence
    Park, Hyo-Bum
    Lee, Sun-Ah
    JOURNAL OF THE KOREAN SOCIETY FOR AERONAUTICAL AND SPACE SCIENCES, 2024, 52 (05) : 423 - 429
  • [33] 3-D ultrasound carotid plaque volume: A tool for quickly measuring effects of treatment on atherosclerosis
    Ainsworth, CD
    Spence, JD
    Landry, AM
    Blake, CC
    Tamayo, A
    Fenster, A
    STROKE, 2004, 35 (01) : 247 - 247
  • [34] COMPARISON OF DEGREE OF STENOSIS AND PLAQUE VOLUME FOR THE ASSESSMENT OF CAROTID ATHEROSCLEROSIS USING 2-D ULTRASOUND
    de Labriolle, Axel
    Mohty, Dania
    Pacouret, Gerard
    Giraudeau, Bruno
    Fichet, Jerome
    Fremont, Benoit
    Fauchier, Laurent
    Charbonnier, Bernard
    Arbeille, Philippe
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2009, 35 (09): : 1436 - 1442
  • [35] Measurement of organ volume using 3D US
    Hughes, SW
    DArcy, TJ
    Ruff, CF
    Maxwell, DJ
    Saunders, JE
    CAR '96: COMPUTER ASSISTED RADIOLOGY, 1996, 1124 : 210 - 215
  • [36] Accurate quantification of atherosclerotic plaque volume by 3D vascular ultrasound using the volumetric linear array method
    Lopez-Melgar, Beatriz
    Fernandez-Friera, Leticia
    Sanchez-Gonzalez, Javier
    Paul Vilchez, Jean
    Cecconi, Alberto
    Mateo, Jesus
    Penalvo, Jose L.
    Oliva, Belen
    Garcia-Ruiz, Jose M.
    Kauffman, Steve
    Jesus Jimenez-Borreguero, Luis
    Ruiz-Cabello, Jesus
    Fernandez-Ortiz, Antonio
    Ibanez, Borja
    Fuster, Valentin
    ATHEROSCLEROSIS, 2016, 248 : 230 - 237
  • [37] Determination of 3D plaque geometry and composition using intravascular ultrasound
    Vince, DG
    Dixon, KJ
    Shekhar, R
    Cothren, RM
    Cornhill, JF
    ATHEROSCLEROSIS, 1997, 134 (1-2) : 271 - 272
  • [38] Non-rigid registration of 3D ultrasound images to monitor carotid plaque changes
    Nanayakkara, N. D.
    Chiu, B.
    Samani, A.
    Spence, J. D.
    Samarabandu, J.
    Fenster, A.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S77 - S77
  • [39] GPU Accelerated Implementation of Kernel Regression for Freehand 3D Ultrasound Volume Reconstruction
    Daoud, Mohammad I.
    Alshalalfah, Abdel-Latif
    A-Najar, Mahasen
    2016 IEEE EMBS CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES), 2016, : 586 - 589
  • [40] MEASUREMENT OF PLACENTAL VOLUME USING 2D AND 3D ULTRASOUND AS COMPARED TO MRI - A PILOT STUDY
    Sommerfelt, Silje
    Hillestad, Vigdis
    Higgins, Lucy
    Sagberg, Karianne
    Halle, Tuva
    Gjesdal, Kjell-Inge
    Borthne, Arne Sigurd
    Eskild, Anne
    PLACENTA, 2017, 57 : 292 - 292