Accelerated Measurement of Carotid Plaque Volume Using Artificial Intelligence Enhanced 3D Ultrasound

被引:0
|
作者
Phair, Alison Shirley [1 ,2 ]
Carreira, Joao [3 ]
Bowling, Frank Lee [1 ,2 ]
Ghosh, Jonathan [1 ,2 ]
Smith, Craig [4 ,5 ]
Rogers, Steven Kristofor [1 ,2 ,6 ]
机构
[1] Univ Manchester, Manchester Univ NHS Fdn Trust, Div Cardiovasc Sci, Manchester Acad Hlth Sci, Manchester, England
[2] Manchester Univ NHS Fdn Trust, Manchester Vasc Ctr, Manchester Acad Vasc Res & Innovat Ctr MAVRIC, Manchester, England
[3] Manchester Univ NHS Fdn Trust, Independent Vasc Serv Ltd, Wythenshawe Hosp, Manchester Acad Hlth Sci Ctr, Manchester, England
[4] Univ Manchester, Lydia Becker Inst Immunol & Inflammat, Div Cardiovasc Sci, Manchester, England
[5] Salford Royal Fdn Trust, Manchester Ctr Clin Neurosci, Geoffrey Jefferson Brain Res Ctr, Manchester Acad Hlth Sci Ctr, Manchester, England
[6] Manchester Univ NHS Fdn Trust, Vasc Studies Unit, Southmoor Rd, Manchester M23 9LT, England
关键词
D O I
10.1016/j.avsg.2023.06.018
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Carotid plaque volume (CPV) can be measured by 3D ultrasound and may be a better predictor of stroke than stenosis, but analysis time limits clinical utility. This study tested the accuracy, reproducibility, and time saved of using an artificial intelligence (AI) derived semiautomatic software to measure CPV ("auto-CPV").Methods: Three-dimensional (3D) ultrasound images for 121 individuals were analyzed by 2 blinded operators to measure auto-CPV. Corresponding endarterectomy specimen volumes were calculated by the validated saline suspension technique. Inter-rater and intrarater agreement plus accuracy compared with the volume of the endarterectomized plaque were calculated. Measurement times were compared with previous manual CPV measurement.Results: The mean difference between auto-CPV and surgical volume was small at (+/- s.d.) [95% confidence interval [CI]] 0.06 (0.24) [-0.41 to 0.54] cm(3). The intraclass correlation (ICC) was strong at 0.91; 95% CI 0.86-0.94. Interobserver and intraobserver error was low with mean difference (+/- s.d.) [95%CI] 0.01 (0.26) [-0.5 to 0.5] cm(3) and 0.03 (0.19) [-0.35 to 0.40] cm(3) respectively. Both showed excellent ICC with narrow confidence intervals, ICC = 0.90; 95% CI (0.85-0.94) and ICC = 0.95; 95% CI (0.92-0.96). Auto-CPV measurement took 43% the time of manual planimetry; median (IQR) 05:39 (01:58) minutes compared to 13:05 (04:15) minutes, Wilcoxon rank-sum test, P < 0.01.Conclusions: Auto-CPV assessment is accurate, reproducible, and significantly faster than manual planimetry. Improved feasibility means that the utility of CPV can be assessed in large population studies to stratify risk in asymptomatic carotid disease or assess response to medical treatment.
引用
收藏
页码:317 / 324
页数:8
相关论文
共 50 条
  • [21] Manual planimetric measurement of carotid plaque volume using three-dimensional ultrasound imaging
    Landry, Anthony
    Ainsworth, Craig
    Blake, Chris
    Spence, J. David
    Fenster, Aaron
    MEDICAL PHYSICS, 2007, 34 (04) : 1496 - 1505
  • [22] Semiautomatic segmentation of atherosclerotic carotid artery wall volume using 3D ultrasound imaging
    Hossain, Md. Murad
    AlMuhanna, Khalid
    Zhao, Limin
    Lal, Brajesh K.
    Sikdar, Siddhartha
    MEDICAL PHYSICS, 2015, 42 (04) : 2029 - 2043
  • [23] ULTRASOUND MORPHOLOGY OF CAROTID PLAQUE AND ITS LINK WITH LIPID: PROTEIN CONTENT AND 3D MICROSTRUCTURE OF THE PLAQUE
    Khattab, A.
    Streletz, L.
    Wertheim, D.
    Ali, I
    Wijesinghe, L.
    Jupp, B.
    Thavanesan, K.
    Gale, D.
    Liddell, J.
    Campell, P.
    INTERNATIONAL JOURNAL OF STROKE, 2017, 12 : 57 - 57
  • [24] Influence of data acquisition on accuracy in carotid plaque volume measurements with 3D-ultrasound
    Delcker, A.
    European Journal of Ultrasound, 1996, 4 (03):
  • [25] INTER-SCAN REPRODUCIBILITY OF CAROTID PLAQUE VOLUME MEASUREMENTS BY 3-D ULTRASOUND
    Sandholt, Benjamin V.
    Collet-Billon, Antoine
    Entrekin, Robert
    Sillesen, Henrik H.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2018, 44 (03): : 670 - 676
  • [26] Inter-rater Agreement in Carotid Atherosclerotic Plaque Evaluation by 3D Ultrasound
    Bar, M.
    Roubec, M.
    Farana, R.
    Licev, L.
    Skoloudik, D.
    CEREBROVASCULAR DISEASES, 2013, 35 : 390 - 390
  • [27] Placental volume measurements using tracked 2D ultrasound and artificial intelligence
    Sagberg, Karianne
    Lie, Torgrim
    Peterson, Helene Fjeldvik
    Hillestad, Vigdis
    Eskild, Anne
    Bo, Lars Eirik
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2023, 102 : 59 - 59
  • [28] Measurement of Placental Volume by 3D Modeling of Ultrasound Placentometry Results
    V. A. Mudrov
    A. K. Lyapunov
    Biomedical Engineering, 2019, 53 : 22 - 27
  • [29] Measurement of Placental Volume by 3D Modeling of Ultrasound Placentometry Results
    Mudrov, V. A.
    Lyapunov, A. K.
    BIOMEDICAL ENGINEERING-MEDITSINSKAYA TEKNIKA, 2019, 53 (01): : 22 - 27
  • [30] Does 3D ultrasound measurement improve the assessment of ovarian volume?
    Brett, S.
    Kelsey, T. W.
    Wallace, W. H. B.
    Rajkhowa, M.
    HUMAN REPRODUCTION, 2007, 22 : I56 - I57