Accelerated Measurement of Carotid Plaque Volume Using Artificial Intelligence Enhanced 3D Ultrasound

被引:0
|
作者
Phair, Alison Shirley [1 ,2 ]
Carreira, Joao [3 ]
Bowling, Frank Lee [1 ,2 ]
Ghosh, Jonathan [1 ,2 ]
Smith, Craig [4 ,5 ]
Rogers, Steven Kristofor [1 ,2 ,6 ]
机构
[1] Univ Manchester, Manchester Univ NHS Fdn Trust, Div Cardiovasc Sci, Manchester Acad Hlth Sci, Manchester, England
[2] Manchester Univ NHS Fdn Trust, Manchester Vasc Ctr, Manchester Acad Vasc Res & Innovat Ctr MAVRIC, Manchester, England
[3] Manchester Univ NHS Fdn Trust, Independent Vasc Serv Ltd, Wythenshawe Hosp, Manchester Acad Hlth Sci Ctr, Manchester, England
[4] Univ Manchester, Lydia Becker Inst Immunol & Inflammat, Div Cardiovasc Sci, Manchester, England
[5] Salford Royal Fdn Trust, Manchester Ctr Clin Neurosci, Geoffrey Jefferson Brain Res Ctr, Manchester Acad Hlth Sci Ctr, Manchester, England
[6] Manchester Univ NHS Fdn Trust, Vasc Studies Unit, Southmoor Rd, Manchester M23 9LT, England
关键词
D O I
10.1016/j.avsg.2023.06.018
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Carotid plaque volume (CPV) can be measured by 3D ultrasound and may be a better predictor of stroke than stenosis, but analysis time limits clinical utility. This study tested the accuracy, reproducibility, and time saved of using an artificial intelligence (AI) derived semiautomatic software to measure CPV ("auto-CPV").Methods: Three-dimensional (3D) ultrasound images for 121 individuals were analyzed by 2 blinded operators to measure auto-CPV. Corresponding endarterectomy specimen volumes were calculated by the validated saline suspension technique. Inter-rater and intrarater agreement plus accuracy compared with the volume of the endarterectomized plaque were calculated. Measurement times were compared with previous manual CPV measurement.Results: The mean difference between auto-CPV and surgical volume was small at (+/- s.d.) [95% confidence interval [CI]] 0.06 (0.24) [-0.41 to 0.54] cm(3). The intraclass correlation (ICC) was strong at 0.91; 95% CI 0.86-0.94. Interobserver and intraobserver error was low with mean difference (+/- s.d.) [95%CI] 0.01 (0.26) [-0.5 to 0.5] cm(3) and 0.03 (0.19) [-0.35 to 0.40] cm(3) respectively. Both showed excellent ICC with narrow confidence intervals, ICC = 0.90; 95% CI (0.85-0.94) and ICC = 0.95; 95% CI (0.92-0.96). Auto-CPV measurement took 43% the time of manual planimetry; median (IQR) 05:39 (01:58) minutes compared to 13:05 (04:15) minutes, Wilcoxon rank-sum test, P < 0.01.Conclusions: Auto-CPV assessment is accurate, reproducible, and significantly faster than manual planimetry. Improved feasibility means that the utility of CPV can be assessed in large population studies to stratify risk in asymptomatic carotid disease or assess response to medical treatment.
引用
收藏
页码:317 / 324
页数:8
相关论文
共 50 条
  • [1] Measurement of Carotid Plaque Volume by 3D Ultrasound
    Al-Mohanna, Khalid
    Hossain, Murad
    Khosravi, Abtin
    Zhao, Limin
    Fischell, Jonathan
    Kowalowski, Gregory
    Sikdar, Siddhartha
    Lal, Brajesh K.
    JOURNAL OF VASCULAR SURGERY, 2014, 59 (06) : 54S - 55S
  • [2] Quantification of carotid plaque volume measurements using 3D ultrasound imaging
    Landry, A
    Spence, JD
    Fenster, A
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (06): : 751 - 762
  • [3] 3D ultrasound analysis of carotid plaque volume and surface morphology
    Fenster, A.
    Blake, C.
    Gyacskov, Igor
    Landry, A.
    Spence, J. D.
    ULTRASONICS, 2006, 44 (e153-e157) : E153 - E157
  • [4] 3D ultrasound measurement of change in carotid plaque volume - A tool for rapid evaluation of new therapies
    Ainsworth, CD
    Blake, CC
    Tamayo, A
    Beletsky, V
    Fenster, A
    Spence, JD
    STROKE, 2005, 36 (09) : 1904 - 1909
  • [5] Plaque Volume of Carotid Endarterectomy Specimens Measured by 3D Ultrasound Technology
    Kumar, Anirudh
    Yang, Eric Y.
    Brunner, Gerd
    Murray, Tyler O.
    Virani, Salim S.
    Garami, Zsolt
    Ballantyne, Christie M.
    Morrisett, Joel D.
    Nambi, Vijay
    JACC-CARDIOVASCULAR IMAGING, 2016, 9 (09) : 1118 - 1119
  • [6] Measurement of carotid plaque volume by 3-dimensional ultrasound
    Landry, A
    Spence, JD
    Fenster, A
    STROKE, 2004, 35 (04) : 864 - 869
  • [7] Reliability of tomographic 3D ultrasound in measuring internal carotid artery plaque volume
    Alzahrani, Adel
    Sultan, Salahaden R.
    Aslam, Mohammed
    ACTA RADIOLOGICA, 2023, 64 (11) : 2931 - 2937
  • [8] Feasibility and Accuracy of Measuring Carotid Plaque Volume (Burden) With Contrast-Enhanced Tomographic 3D Ultrasound and Ultrasound Image Fusion
    Rogers, S. K.
    Phair, A.
    Carriera, J.
    Ghosh, J.
    Bowling, F. L.
    McCollum, C.
    ANNALS OF VASCULAR SURGERY, 2023, 91 : 168 - 175
  • [9] 3D object volume measurement using freehand ultrasound
    Bogush, AL
    Tuzikov, AV
    IMAGE ANALYSIS, PROCEEDINGS, 2005, 3540 : 1066 - 1075
  • [10] Semiautomatic Quantification of Carotid Plaque Volume With 3D Ultrasonography
    Lal, Brajesh K.
    Khan, Amir A.
    Koudelka, Christian
    Zhao, Limin
    Dux, Moira
    Goldstein, Carly B.
    JOURNAL OF VASCULAR SURGERY, 2016, 63 (06) : 186S - 186S