Improved imaging technique for nondestructive evaluation using arbitrary virtual array source aperture (AVASA)

被引:3
|
作者
Gantala, Thulsiram [1 ]
Sudharsan, P. L. [1 ]
Balasubramaniam, Krishnan [1 ]
机构
[1] Indian Inst Technol Madras, Ctr Nondestruct Evaluat, Dept Mech Engn, Chennai 600036, India
关键词
Ultrasonic phase array; Arbitrary virtual source; FMC; TFM; Beamforming; Improved imaging; ULTRASONIC INSPECTION; FULL MATRIX; OPTIMIZATION; TRANSDUCER;
D O I
10.1016/j.ndteint.2023.102869
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In this paper, we propose a new phased array imaging technique called Arbitrary Virtual Array Source Aperture (AVASA) to image deeper defects with an improved SNR with fewer transmissions. The approach is to transmit the ultrasound waves by electronic beamforming at several arbitrary virtual source positions to achieve higher focal depth to increase the SNR of the received A-scans. Backscattered signals are recorded with all the array elements. A high-resolution image is obtained on reception by virtually focusing on every point in the region of interest by signal coherence summation. In this paper, the proposed AVASA and TFM methods are employed for scanning the larger thickness structure with an unknown defect nature to contrast the defect SNR and the number of defect imaging. Compared with TFM imaging, the AVASA method shows a significantly increasing defect-detecting range with higher amplitude. To further improve the imaging quality and reduce the reconstruction time, the influence of the virtual source parameters on the AVASA imaging and a scanning strategy is demonstrated. A good agreement between the AVASA and TFM is observed, and the number of transmissions is required to inspect the test specimen using AVASA reduced by a factor of four to eight.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Microwave Nondestructive Imaging of Buried Objects Using Improved Scattered-Field Calibration Technique
    Govind, Greeshmaja
    Akhtar, M. J.
    RADIO SCIENCE, 2018, 53 (01) : 2 - 14
  • [22] Fast Focusing of Ultrasound Synthetic Aperture Imaging by Using Virtual Array and Nonuniform Fast Fourier Transform
    Cui, Jian
    Li, Zhaohui
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (10) : 7328 - 7340
  • [23] Multiple virtual source aperture imaging for non-destructive testing
    Sutcliffe, M.
    Charlton, P.
    Weston, M.
    INSIGHT, 2014, 56 (02) : 75 - 81
  • [24] Synthetic Aperture Integral Imaging Display With Moving Array Lenslet Technique
    Wang, Jingang
    Xiao, Xiao
    Yao, Gang
    Stern, Adrian
    Javidi, Bahram
    JOURNAL OF DISPLAY TECHNOLOGY, 2015, 11 (10): : 827 - 833
  • [25] In-vivo evaluation of convex array synthetic aperture imaging
    Pedersen, Morten H.
    Gammelmark, Kim L.
    Jensen, Jorgen A.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (01): : 37 - 47
  • [27] Cross-range imaging of a cooperative source using passive inverse synthetic aperture technique
    Parmeswaran, H.
    Bahl, R.
    Kumar, A.
    Gupta, R.
    2013 IEEE INTERNATIONAL UNDERWATER TECHNOLOGY SYMPOSIUM (UT), 2013,
  • [28] Signal to Noise Ratio Analysis in Virtual Source Array Imaging
    Garnier, Josselin
    Papanicolaou, George
    Semin, Adrien
    Tsogka, Chrysoula
    SIAM JOURNAL ON IMAGING SCIENCES, 2015, 8 (01): : 248 - 279
  • [30] Resolution-enhanced holographic stereogram based on integral imaging using a moving array lenslet technique and an aperture array filter
    Dai, Piao
    Lv, Guoqiang
    Wang, Zi
    Zhang, Xu
    Gong, Xin
    Feng, Qibin
    APPLIED OPTICS, 2019, 58 (30) : 8207 - 8212