Synthetic Aperture Integral Imaging Display With Moving Array Lenslet Technique

被引:9
|
作者
Wang, Jingang [1 ]
Xiao, Xiao [1 ]
Yao, Gang [1 ]
Stern, Adrian [2 ]
Javidi, Bahram [1 ]
机构
[1] Univ Connecticut, Dept Elect & Comp Engn, Storrs, CT 06269 USA
[2] Ben Gurion Univ Negev, Electroopt Engn Dept, IL-81405 Beer Sheva, Israel
来源
JOURNAL OF DISPLAY TECHNOLOGY | 2015年 / 11卷 / 10期
关键词
Integral imaging; synthetic aperture; 3D display; non-stationary display; moving array lenslet technique (MALT); 3-DIMENSIONAL IMAGES; RESOLUTION LIMITATION; HOLOGRAPHIC DISPLAY; PHOTOGRAPHY; PROJECTION; DEPTH; REAL;
D O I
10.1109/JDT.2015.2408217
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We propose a method to improve the visual resolution of integral imaging by synchronously moving both a lenslet array and a display device to overcome the limited sampling rate using a stationary lenslet array. Compared to the previous moving array lenslet technique approach, the proposed approach can achieve more accurate sub-pixel movements. Experimental 3D reconstruction results using a non-stationary smart phone are presented to show the visual resolution improvement for the proposed integral imaging 3D display.
引用
收藏
页码:827 / 833
页数:7
相关论文
共 50 条
  • [1] Dynamic integral imaging display with electrically moving array lenslet technique using liquid crystal lens
    Jen, Tai-Hsiang
    Shen, Xin
    Yao, Gang
    Huang, Yi-Pai
    Shieh, Han-Ping D.
    Javidi, Bahram
    [J]. OPTICS EXPRESS, 2015, 23 (14): : 18415 - 18421
  • [2] Resolution-enhanced holographic stereogram based on integral imaging using a moving array lenslet technique and an aperture array filter
    Dai, Piao
    Lv, Guoqiang
    Wang, Zi
    Zhang, Xu
    Gong, Xin
    Feng, Qibin
    [J]. APPLIED OPTICS, 2019, 58 (30) : 8207 - 8212
  • [3] Depth extraction method with high accuracy in integral imaging based on moving array lenslet technique
    Wang Y.-Y.
    Zhang J.
    Zhao X.-W.
    Song L.-P.
    Zhang B.
    Zhao X.
    [J]. Optoelectronics Letters, 2018, 14 (2) : 148 - 151
  • [4] Depth extraction method with high accuracy in integral imaging based on moving array lenslet technique
    王尧尧
    张娟
    赵雪微
    宋丽培
    张勃
    赵星
    [J]. Optoelectronics Letters, 2018, 14 (02) : 148 - 151
  • [5] Resolution-enhanced holographic stereogram based on integral imaging using moving array lenslet technique
    Wang, Z.
    Chen, R. S.
    Zhang, X.
    Lv, G. Q.
    Feng, Q. B.
    Hu, Z. A.
    Ming, H.
    Wang, A. T.
    [J]. APPLIED PHYSICS LETTERS, 2018, 113 (22)
  • [6] Calibration of an integral imaging system with a lenslet array
    Li, W.
    Li, Y. F.
    Yu, Z.
    Wang, K.
    [J]. 2010 PROGNOSTICS AND SYSTEM HEALTH MANAGEMENT CONFERENCE, 2010, : 336 - +
  • [7] Hybrid pixel mapping reconstruction method of axially moving lenslet array in integral imaging with arbitrary moving gap
    Wang, Yaoyao
    Zhang, Juan
    Zhao, Xuewei
    Zhang, Bo
    Song, Lipei
    Zhao, Xing
    [J]. OPTICAL ENGINEERING, 2018, 57 (06)
  • [8] An integral imaging three dimensional display method based on aperture stop array
    [J]. Deng, Huan, 1600, Chinese Optical Society (34):
  • [9] Hologram synthesis using integral imaging camera with synthetic aperture technique
    Lee, Sung-Keun
    Kim, Yong-Soo
    Hong, Sung-In
    Park, Jae-Hyeung
    [J]. STEREOSCOPIC DISPLAYS AND APPLICATIONS XXIV, 2013, 8648
  • [10] Analysis of synthetic aperture integral imaging
    Tavakoli, Behnoosh
    DaneshPanah, Mehdi
    Javidi, Bahram
    Watson, Edward
    [J]. THREE-DIMENSIONAL TV, VIDEO, AND DISPLAY VI, 2007, 6778