MCNPX Estimation of Photoneutron Dose to Eye Voxel Anthropomorphic Phantom From 18 MV Linear Accelerator

被引:0
|
作者
Alghamdi, Ali A. A. [1 ,2 ]
机构
[1] Imam Abdulrahman Bin Faisal Univ, Coll Appl Med Sci, Dept Radiol Sci, Dammam, Saudi Arabia
[2] Imam Abdulrahman Bin Faisal Univ, Coll Appl Med Sci, Dept Radiol Sci, POB 2435, Dammam 31441, Saudi Arabia
来源
DOSE-RESPONSE | 2023年 / 21卷 / 02期
关键词
photoneutron dose; eye model; voxel anthropomorphic phantom; weight window; MONTE-CARLO; NEUTRON; RADIOTHERAPY; COMPOSITES; THERAPY; FIELD;
D O I
10.1177/15593258231169807
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The dose due to photoneutron contamination outside the field of irradiation can be significant when using high-energy linear accelerators. The eye is a radiation-sensitive organ, and this risk increases when high linear energy transfer neutron radiation is involved. This study aimed to provide a fast method to estimate photoneutron dose to the eye during radiotherapy. A typical high-energy linear accelerator operating at 18 MV was simulated using the Monte Carlo N-Particle Transport Code System extended version (MCNPX 2.5.0). The latest International Atomic Energy Agency photonuclear data library release was integrated into the code, accounting for the most known elements and isotopes used in typical linear accelerator construction. The photoneutron flux from a 5 x 5 cm(2) field size was scored at the treatment table plane and used as a new source for estimating the absorbed dose in a high-resolution eye voxel anthropomorphic phantom. In addition, common shielding media were tested to reduce the photoneutron dose to the eye using common shielding materials. Introducing a 2 cm thickness of common neutron shielding medium reduced the total dose received in the eye voxel anthropomorphic phantom by 54%. In conclusion, individualized treatment based on photoneutron dose assessment is essential to better estimate the secondary dose inside or outside the field of irradiation.
引用
收藏
页数:7
相关论文
共 44 条
  • [1] Monte Carlo simulation of photoneutron dose in radiotherapy with linear accelerators using an anthropomorphic voxel phantom
    Frankl, M.
    Macian, R.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 (08) : 749 - 750
  • [2] PHOTONEUTRON CONTAMINATION FROM AN 18 MV SATURNE MEDICAL LINEAR ACCELERATOR IN THE TREATMENT ROOM
    Khosravi, Mostafa
    Shahbazi-Gahrouei, Daryoush
    Jabbari, Keyvan
    Nasri-Nasrabadi, Mehdi
    Baradaran-Ghahfarokhi, Milad
    Siavashpour, Zahra
    Gheisari, Ruhollah
    Amiri, Behnam
    RADIATION PROTECTION DOSIMETRY, 2013, 156 (03) : 356 - 363
  • [3] In-phantom dosimetry and spectrometry of photoneutrons from an 18 MV linear accelerator
    d'Errico, F
    Nath, R
    Tana, L
    Curzio, G
    Alberts, WG
    MEDICAL PHYSICS, 1998, 25 (09) : 1717 - 1724
  • [4] INVESTIGATION OF PHOTONEUTRON CONTAMINATION FROM THE 18-MV PHOTON BEAM IN A MEDICAL LINEAR ACCELERATOR
    Karaman, Onur
    Tanir, Ayse Gunes
    Karaman, Ceren
    MATERIALI IN TEHNOLOGIJE, 2019, 53 (05): : 699 - 704
  • [5] New aspect determination of photoneutron contamination in 18 MV medical linear accelerator
    Mohammadi, A.
    Afarideh, H.
    Davani, F. Abbasi
    Arbabi, A.
    RADIATION MEASUREMENTS, 2016, 95 : 55 - 61
  • [6] Photoneutron Flux Measurement via NAA in a Radiotherapy Bunker with an 18 MV Linear Accelerator
    Gulumser, T.
    Cecen, Y.
    Yesil, A. H.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S764 - S765
  • [7] Effect of wedge filter and field size on photoneutron dose equivalent for an 18 MV photon beam of a medical linear accelerator
    Mesbahi, Asghar
    Keshtkar, Ahmad
    Mohammadi, Ehsan
    Mohammadzadeh, Mohammad
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (01) : 84 - 89
  • [8] Estimation of photoneutron intensities around radiotherapy linear accelerator 23-MV photon beam
    Shweikani, R.
    Anjak, O.
    APPLIED RADIATION AND ISOTOPES, 2015, 99 : 168 - 171
  • [9] Estimation of photoneutron yield in linear accelerator with different collimation systems by Geant4 and MCNPX simulation codes
    Kim, Yoon Sang
    Khazaei, Zeinab
    Ko, Junho
    Afarideh, Hossein
    Ghergherehchi, Mitra
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (07): : 2762 - 2779
  • [10] Monte Carlo estimation of photoneutrons spectra and dose equivalent around an 18 MV medical linear accelerator
    Alem-Bezoubiri, A.
    Bezoubiri, F.
    Badreddine, A.
    Mazrou, H.
    Lounis-Mokrani, Z.
    RADIATION PHYSICS AND CHEMISTRY, 2014, 97 : 381 - 392