MCNPX Estimation of Photoneutron Dose to Eye Voxel Anthropomorphic Phantom From 18 MV Linear Accelerator

被引:0
|
作者
Alghamdi, Ali A. A. [1 ,2 ]
机构
[1] Imam Abdulrahman Bin Faisal Univ, Coll Appl Med Sci, Dept Radiol Sci, Dammam, Saudi Arabia
[2] Imam Abdulrahman Bin Faisal Univ, Coll Appl Med Sci, Dept Radiol Sci, POB 2435, Dammam 31441, Saudi Arabia
来源
DOSE-RESPONSE | 2023年 / 21卷 / 02期
关键词
photoneutron dose; eye model; voxel anthropomorphic phantom; weight window; MONTE-CARLO; NEUTRON; RADIOTHERAPY; COMPOSITES; THERAPY; FIELD;
D O I
10.1177/15593258231169807
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The dose due to photoneutron contamination outside the field of irradiation can be significant when using high-energy linear accelerators. The eye is a radiation-sensitive organ, and this risk increases when high linear energy transfer neutron radiation is involved. This study aimed to provide a fast method to estimate photoneutron dose to the eye during radiotherapy. A typical high-energy linear accelerator operating at 18 MV was simulated using the Monte Carlo N-Particle Transport Code System extended version (MCNPX 2.5.0). The latest International Atomic Energy Agency photonuclear data library release was integrated into the code, accounting for the most known elements and isotopes used in typical linear accelerator construction. The photoneutron flux from a 5 x 5 cm(2) field size was scored at the treatment table plane and used as a new source for estimating the absorbed dose in a high-resolution eye voxel anthropomorphic phantom. In addition, common shielding media were tested to reduce the photoneutron dose to the eye using common shielding materials. Introducing a 2 cm thickness of common neutron shielding medium reduced the total dose received in the eye voxel anthropomorphic phantom by 54%. In conclusion, individualized treatment based on photoneutron dose assessment is essential to better estimate the secondary dose inside or outside the field of irradiation.
引用
收藏
页数:7
相关论文
共 44 条
  • [11] Photoneutron Flux Measurement via Neutron Activation Analysis in a Radiotherapy Bunker with an 18 MV Linear Accelerator
    Cecen, Yigit
    Gulumser, Tugce
    Yazgan, Cagri
    Dapo, Haris
    Ustun, Mahmut
    Boztosun, Ismail
    ICRS-13 & RPSD-2016, 13TH INTERNATIONAL CONFERENCE ON RADIATION SHIELDING & 19TH TOPICAL MEETING OF THE RADIATION PROTECTION AND SHIELDING DIVISION OF THE AMERICAN NUCLEAR SOCIETY - 2016, 2017, 153
  • [12] EFFECTS OF FIELD SIZE AND DEPTH ON PHOTONEUTRON DOSE EQUIVALENT DISTRIBUTIONS IN AN 18 MV X-RAY MEDICAL ACCELERATOR
    Hakimi, Amir
    Sohrabi, Mehdi
    Mahdavi, Seied Rabie
    RADIATION PROTECTION DOSIMETRY, 2017, 176 (04) : 354 - 364
  • [13] A model to calculate the induced dose rate around an 18 MV ELEKTA linear accelerator
    Perrin, B
    Walker, A
    Mackay, R
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (05): : N75 - N81
  • [14] The influence of field size and off-axis distance on photoneutron spectra of the 18 MV Siemens Oncor linear accelerator beam
    Brkic, Hrvoje
    Ivkovic, Ana
    Kasabasic, Mladen
    Sovilj, Marina Poje
    Jurkovic, Slaven
    Stimac, Damir
    Rubin, Otmar
    Faj, Dario
    RADIATION MEASUREMENTS, 2016, 93 : 28 - 34
  • [15] Monte Carlo estimation of absorbed dose distributions in an anthropomorphic phantom obtained from heterogeneous Ru-106 eye plaques
    Zaragoza, F. J.
    Eichmann, M.
    Fluehs, D.
    Sauerwein, W.
    Brualla, L.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2017, 193 : S11 - S12
  • [16] Peripheral dose measurements for 6 and 18 MV photon beams on a linear accelerator with multileaf collimator
    Mazonakis, Michalis
    Zacharopoulou, Fotini
    Varveris, Haralambos
    Damilakis, John
    MEDICAL PHYSICS, 2008, 35 (10) : 4396 - 4403
  • [17] Evaluation of the use of 18 MV photons from a siemens linear accelerator for IMRT
    Price, R
    Ma, C
    Chibani, O
    MEDICAL PHYSICS, 2003, 30 (06) : 1493 - 1493
  • [18] Scattered fractions of dose from 6, 10, 18, and 25 MV linear accelerator X rays in radiotherapy facilities
    Shobe, J
    Rodgers, JE
    Taylor, PL
    HEALTH PHYSICS, 1999, 76 (01): : 27 - 35
  • [19] A dose-response curve for biodosimetry from a 6 MV electron linear accelerator
    Lemos-Pinto, M. M. P.
    Cadena, M.
    Santos, N.
    Fernandes, T. S.
    Borges, E.
    Amaral, A.
    BRAZILIAN JOURNAL OF MEDICAL AND BIOLOGICAL RESEARCH, 2015, 48 (10) : 908 - 914
  • [20] An integrated 6 MV linear accelerator model from electron gun to dose in a water tank
    St. Aubin, J.
    Steciw, S.
    Kirkby, C.
    Fallone, B. G.
    MEDICAL PHYSICS, 2010, 37 (05) : 2279 - 2288