Simultaneous Determination of Doxorubicin and Dasatinib by using Screen-Printed Electrode/Ni-Fe Layered Double Hydroxide

被引:9
|
作者
Mohammadi, Sayed Zia [1 ]
Mousazadeh, Farideh [1 ]
Tajik, Somayeh [2 ]
机构
[1] Payame Noor Univ, Dept Chem, Tehran 00000, Iran
[2] Kerman Univ Med Sci, Res Ctr Trop & Infect Dis, Kerman 00000, Iran
关键词
GLASSY-CARBON ELECTRODE; IONIC LIQUID; SENSOR; NANOPARTICLES;
D O I
10.1021/acs.iecr.2c03105
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Doxorubicin (DOX) and Dasatinib (DAS) are important chemotherapy medications that are widely used to treat a variety of cancers, but unfortunately, despite the many benefits of DOX, this drug has numerous reported complications. Therefore, the concurrent administration of DAS and DOX can help better treat breast cancer. The current attempt was made to produce Ni-Fe layered double hydroxide (Ni-Fe LDH) to construct a novel selective and sensitive electrochemical DOX sensor. The characteristics of synthesized Ni-Fe LDH was determined by X-ray diffraction, Fourier transform infrared spectrometry, and field emission scanning electron microscopy. The sensor fabrication was based on the surface modification of a screen-printed electrode (SPE) with Ni-Fe LDH (Ni-Fe LDH/SPE). The Ni-Fe LDH/SPE possessed an appropriate response and an appreciable electrocatalytic behavior toward the detection of DOX and DAS. There was a significant enhancement in the DOX and DAS electro-oxidation signals on the Ni-Fe LDH/SPE surface compared to that on the bare SPE. The proposed protocol was explored by chronoamperometry, cyclic voltammetry, and differential pulse voltammetry (DPV). The DPV findings clarified a broad linear relationship between DOX concentrations, and the peak height ranged from 0.04 to 585.0 mu M with a limit of detection as narrow as 0.01 mu M. The practical potency of Ni-Fe LDH/SPE was confirmed by sensing DOX and DAS in biological matrices.
引用
收藏
页码:4646 / 4654
页数:9
相关论文
共 50 条
  • [31] Tribological Behavior of GTL Base Oil Improved by Ni-Fe Layered Double Hydroxide Nanosheets
    Xiang, Shuo
    Zhi, Xinghao
    Bao, Hebin
    He, Yan
    Zhang, Qinhui
    Lin, Shigang
    Hu, Bo
    Wang, Senao
    Lu, Peng
    Yang, Xin
    Tian, Qiang
    Du, Xin
    LUBRICANTS, 2024, 12 (05)
  • [32] Simultaneous Detection of Morphine and Diclofenac Using Graphene Nanoribbon Modified Screen-Printed Electrode
    Jahani, Peyman Mohamadzadeh
    Mohammadi, Sayed Zia
    Khodabakhshzadeh, Ali
    Cha, Joo Hwan
    Asl, Mehdi Shahedi
    Shokouhimehr, Mohammadreza
    Zhang, Kaiqiang
    Quyet Van Le
    Peng, Wanxi
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (09): : 9037 - 9048
  • [33] Simultaneous detection of copper and lead ions using dithizone modified screen-printed electrode
    Yu, L., 1734, South China University of Technology, Guangzhou, 510640, China (29):
  • [34] Enhanced voltammetric response of monosodium glutamate on screen-printed electrodes modified with NiAl layered double hydroxide films
    Baciu, Dora Domnica
    Birjega, Ruxandra
    Marascu, Valentina
    Zavoianu, Rodica
    Matei, Andreea
    Vlad, Angela
    Cojocaru, Anca
    Visan, Teodor
    SURFACES AND INTERFACES, 2021, 24
  • [35] Catalytic degradation of norfloxacin using persulfate activation by Ni-Fe layered double hydroxide catalyst supported on activated carbon
    Adly, Adel
    Galal, Mona M.
    Matta, Minerva E.
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [36] Simultaneous determination of ascorbic acid, dopamine and uric acid using high-performance screen-printed graphene electrode
    Ping, Jianfeng
    Wu, Jian
    Wang, Yixian
    Ying, Yibin
    BIOSENSORS & BIOELECTRONICS, 2012, 34 (01): : 70 - 76
  • [37] Simultaneous determination of dihydroxybenzene isomers using disposable screen-printed electrode modified by multiwalled carbon nanotubes and gold nanoparticles
    Li, Da-Wei
    Li, Yuan-Ting
    Song, Wei
    Long, Yi-Tao
    ANALYTICAL METHODS, 2010, 2 (07) : 837 - 843
  • [38] The Determination of Peroxide Value of Edible Oils Using Chitosan Modified Screen-printed Electrode
    Tao, Sha
    Chen, Fusheng
    Tatsumi, Eizo
    Xue, Wentong
    ELECTROCHEMISTRY, 2013, 81 (11) : 900 - 905
  • [39] Determination of Lead(II) Using Screen-Printed Bismuth-Antimony Film Electrode
    Chen, Chen
    Niu, Xiangheng
    Chai, Yan
    Zhao, Hongli
    Lan, Minbo
    Zhu, Yonggang
    Wei, Gang
    ELECTROANALYSIS, 2013, 25 (06) : 1446 - 1452
  • [40] Anodic stripping voltammetric determination of aurothiomalate in urine using a screen-printed carbon electrode
    Bergamini, Marcio F.
    Boldrin Zanoni, Maria Valnice
    ELECTROANALYSIS, 2006, 18 (15) : 1457 - 1462