Comparison of Corneal Higher-order Aberrations Measured by Scheimpflug Camera and Placido Disc-based Topography in Korean Patients

被引:0
|
作者
Lim, Yeon Ju [1 ]
Jung, Do Hee [1 ]
Pak, Kang Yeun [1 ]
Cho, Chan-Ho [1 ,2 ]
机构
[1] Inje Univ, Haeundae Paik Hosp, Dept Ophthalmol, Coll Med, Pusan, South Korea
[2] Inje Univ, Coll Med, Haeundae Paik Hosp, Dept Ophthalmol, 875 Haeun Daero, Busan 48108, South Korea
来源
关键词
Corneal higher-order aberrations; iTrace (TM); Pentacam (R) HR; STATISTICAL-METHODS; PRINCIPLES; THICKNESS; EYES;
D O I
10.3341/jkos.2023.64.12.1141
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: We compared corneal higher-order aberration (HOA) measurements between the Pentacam (R) HR (PC), which uses the Scheimpflug principle, and the iTrace (TM) aberrometer (IT), which evaluates Placido disc topography.Methods: We retrospectively analyzed 109 eyes of 87 patients without a history of ocular surface disease during the period from January 2021 to December 2022; both devices were used on the same day. We calculated the root mean square values (mu m) of corneal total HOA and of the corneal 3rd-and 4th-order HOA at a pupil diameter of 4 mm. Data were compared by Bland-Altman plots for agreement analysis and Pearson correlation coefficient for correlation analysis.Results: There was no significant difference in the total HOA (p = 0.145), coma (p = 0.309), or secondary astigmatism (p = 0.080) between the PC and IT measurements; all other HOAs significantly differed between devices (p < 0.001). In the correlation analysis, the total HOA (r = 0.605, p < 0.001) and coma (r = 0.634, p < 0.001) were moderately correlated between the two devices; the other HOAs showed low degree of correlations. In the Bland-Altman plot analysis, all HOAs showed low agreement between the two devices.Conclusions: Corneal total HOA and coma measured by the two devices were significantly correlated between the two devices, but other HOAs showed significant differences in measurement and low correlations. Therefore, corneal HOA measurements cannot be interpreted interchangeably between the two devices.
引用
下载
收藏
页码:1141 / 1151
页数:11
相关论文
共 50 条
  • [1] Comparison of anterior corneal aberrations measured by Scheimpflug and Placido Disc System for myopes
    Lou, Wei
    Du, Wei
    Jin, Haiying
    Hu, Ying
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [2] Comparison of anterior corneal aberrations measured by Scheimpflug and Placido Disc System for myopes
    Wei Lou
    Wei Du
    Haiying Jin
    Ying Hu
    BMC Ophthalmology, 22
  • [3] Evaluation of Corneal Higher-Order Aberrations by Scheimpflug-Placido Topography in Patients with Different Refractive Errors: A Retrospective Observational Study
    Anbar, Mohamed
    Mostafa, Engy Mohamed
    Elhawary, Ashraf Mostafa
    Awny, Islam
    Farouk, Mahmoud Mohamed
    Mounir, Amr
    JOURNAL OF OPHTHALMOLOGY, 2019, 2019
  • [4] Corneal higher-order aberrations measurements: Comparison between Scheimpflug and dual Scheimpflug-Placido technology in keratoconic eyes
    Piccinini, Andre L.
    Golan, Oren
    Torres-Netto, Emilio A.
    Hafezi, Farhad
    Randleman, J. Bradley
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (07): : 985 - 991
  • [5] Corneal Higher-Order Aberrations Measurements: Precision of SD-OCT/Placido Topography and Comparison with a Scheimpflug/Placido Topography in Eyes After Small-Incision Lenticule Extraction
    Rui Ning
    Xiaomin Huang
    Yili Jin
    Chak Seng Lei
    Xindi Ma
    Shuoyu Xu
    Jinxuan Xiahou
    Giacomo Savini
    Domenico Schiano-Lomoriello
    Xiaoying Wang
    Xingtao Zhou
    Jinhai Huang
    Ophthalmology and Therapy, 2023, 12 : 1595 - 1610
  • [6] Corneal Higher-Order Aberrations Measurements: Precision of SD-OCT/Placido Topography and Comparison with a Scheimpflug/Placido Topography in Eyes After Small-Incision Lenticule Extraction
    Ning, Rui
    Huang, Xiaomin
    Jin, Yili
    Lei, Chak Seng
    Ma, Xindi
    Xu, Shuoyu
    Xiahou, Jinxuan
    Savini, Giacomo
    Schiano-Lomoriello, Domenico
    Wang, Xiaoying
    Zhou, Xingtao
    Huang, Jinhai
    OPHTHALMOLOGY AND THERAPY, 2023, 12 (03) : 1595 - 1610
  • [7] Repeatability and reproducibility of corneal higher-order aberrations measurements after small incision lenticule extraction using the Scheimpflug-Placido topographer
    Ning, Rui
    Gao, Rongrong
    Pinero, David P.
    Zhang, Jun
    Gao, Qingyi
    Jin, Yili
    Wang, Yiran
    Wang, Chenxiao
    Huang, Jinhai
    EYE AND VISION, 2022, 9 (01)
  • [8] Repeatability and reproducibility of corneal higher-order aberrations measurements after small incision lenticule extraction using the Scheimpflug-Placido topographer
    Rui Ning
    Rongrong Gao
    David P. Piñero
    Jun Zhang
    Qingyi Gao
    Yili Jin
    Yiran Wang
    Chenxiao Wang
    Jinhai Huang
    Eye and Vision, 9
  • [9] Higher-order aberration measurements: Comparison between Scheimpflug and dual Scheimpflug-Placido technology in normal eyes
    Piccinini, Andre L.
    Golan, Oren
    Hafezi, Farhad
    Randleman, J. Bradley
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (04): : 490 - 494
  • [10] Repeatability and Agreement of Horizontal Corneal Diameter Measurements Between Scanning-Slit Topography, Dual Rotating Scheimpflug Camera With Placido Disc Tomography, Placido Disc Topography, and Optical Coherence Tomography
    Namkung, Soobin
    Boyle, Alexander Buckenham
    Li, Ye
    Gokul, Akilesh
    McGhee, Charles
    Ziaei, Mohammed
    CORNEA, 2022, 41 (11) : 1392 - 1397