Development and Reliability of a Visual-Cognitive Reactive Triple Hop Test

被引:2
|
作者
Farraye, Byrnadeen T. [1 ,2 ]
Simon, Janet E. [2 ,3 ]
Chaput, Meredith [1 ,2 ]
Kim, HoWon [1 ,2 ]
Monfort, Scott M. [4 ]
Grooms, Dustin R. [1 ,2 ,3 ]
机构
[1] Ohio Univ, Coll Hlth Sci & Profess, Sch Rehabil & Commun Sci, Div Phys Therapy, Athens, OH 45701 USA
[2] Ohio Univ, Ohio Musculoskeletal & Neurol Inst, Athens, OH 45701 USA
[3] Ohio Univ, Coll Hlth Sci & Profess, Sch Appl Hlth Sci & Wellness, Div Athlet Training, Athens, OH USA
[4] Montana State Univ, Dept Mech & Ind Engn, Bozeman, MT USA
基金
美国国家卫生研究院;
关键词
peripheral visual attention; visual working memory; lower-extremity; response inhibition; return to sport testing; TEST-RETEST RELIABILITY; ACL RECONSTRUCTION; NEUROCOGNITIVE FUNCTION; REACTION-TIME; INJURY RISK; DUAL-TASK; PERFORMANCE; STRENGTH; SPORTS;
D O I
10.1123/jsr.2022-0398
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Context: Current lower-extremity return to sport testing primarily considers the physical status of an athlete; however, sport participation requires continuous cognitive dual-task engagement. Therefore, the purpose was to develop and evaluate the reliability of a visual-cognitive reactive (VCR) triple hop test that simulates the typical sport demand of combined online visual cognitive processing and neuromuscular control to improve return to sport testing after lower-extremity injury. Design: Test- retest reliability. Methods: Twenty-one healthy college students (11 females, 23.5 [3.7] y, 1.73 [0.12] m, 73.0 [16.8] kg, Tegner Activity Scale 5.5 [1.1] points) participated. Participants performed a single-leg triple hop with and without a VCR dual task. The VCR task incorporated the FitLight system to challenge peripheral response inhibition and central working memory. Maximum hop distance, reaction time, cognitive errors, and physical errors were measured. Two identical testing visits were separated by 12 to 17 days (14 [1] d). Results: Traditional triple hop (intraclass correlation coefficients: ICC(3,1) = .96 [.91-.99]; standard error of the measurement = 16.99 cm) and the VCR triple hop (intraclass correlation coefficients(3,1) = .92 [.82-.97]; standard error of the measurement = 24.10 cm) both demonstrated excellent reliability for the maximum hop distance, and moderate reliability for the VCR triple hop reaction time (intraclass correlation coefficients(3,1) = .62 [.09-.84]; standard error of the measurement = 0.09 s). On average, the VCR triple hop resulted in a hop distance deficit of 8.17% (36.4 [5.1] cm; P < .05, d = 0.55) relative to the traditional triple hop. Conclusions: Hop distance on the VCR triple hop had excellent test-retest reliability and induced a significant physical performance deficit when compared with the traditional triple hop assessment. The VCR triple hop reaction time also demonstrated moderate reliability.
引用
收藏
页码:802 / 809
页数:8
相关论文
共 50 条
  • [41] Reliability of the Coimbra Reactive Agility Soccer Test (CRAST)
    Nobrega, Antonio
    Sarmento, Hugo
    Vaz, Vasco
    Gouveia, Vitor
    Barrera, Joel
    Martins, Andreia
    Santos, Tomas
    Duarte, Joao Pedro
    JOURNAL OF FUNCTIONAL MORPHOLOGY AND KINESIOLOGY, 2023, 8 (01)
  • [42] Reliability and Validity of a Reactive Agility Test for Australian Football
    Veale, James P.
    Pearce, Alan J.
    Carlson, John S.
    INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2010, 5 (02) : 239 - 248
  • [43] DEVELOPMENT OF A VISUAL LOCALIZATION TEST
    HAYNES, HM
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1976, 53 (09): : 565 - 565
  • [44] Joint throughput and transmission range optimization for triple-hop networks with cognitive relay
    Cheng Zhao
    Wan-liang Wang
    Xin-wei Yao
    Shuang-hua Yang
    Frontiers of Information Technology & Electronic Engineering, 2017, 18 : 253 - 261
  • [45] Joint throughput and transmission range optimization for triple-hop networks with cognitive relay
    Zhao, Cheng
    Wang, Wan-liang
    Yao, Xin-wei
    Yang, Shuang-hua
    FRONTIERS OF INFORMATION TECHNOLOGY & ELECTRONIC ENGINEERING, 2017, 18 (02) : 253 - 261
  • [46] Reliability of a Visual Test for the Rapid Detection of Mucopolysaccharidoses: GAG-Test®
    Lage, Sergio
    Prieto, Jose A.
    Andrade, Fernando
    Sojo, Amaia
    Sanjurjo, Pablo
    Aldamiz-Echevarria, Luis J.
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2011, 25 (03) : 179 - 184
  • [47] RELIABILITY OF THE TRIPLE-TIMED UP-AND-GO TEST
    Sanders, Donald B.
    Guptill, Jeffrey T.
    Ales, Kathy L.
    Hobson-Webb, Lisa D.
    Jacobus, David P.
    Mahmood, Riaz
    Massey, Janice M.
    Pittman, Melissa M.
    Prather, Kristi
    Raja, Shruti M.
    Yow, Eric
    Juel, Vern C.
    MUSCLE & NERVE, 2018, 57 (01) : 136 - 139
  • [48] The triple test as a screening technique for Down syndrome: reliability and relevance
    Reynolds, Tim
    INTERNATIONAL JOURNAL OF WOMENS HEALTH, 2010, 2 : 83 - 88
  • [49] The Triple-Negative Test for Alcohol Dependence: A Reliability Study
    O'Connor, Kevin
    Meyer, Vickie
    Chard, Annette
    Nagel, Joel
    Jones, Ronald J.
    Bokhart, Gordon H.
    Kunkle, William A.
    Zimmerman, Steven A.
    Reed, Donald N., Jr.
    AMERICAN SURGEON, 2016, 82 (06) : E120 - E122
  • [50] Reliability of a qualitative movement assessment tool during a single-leg triple hop landing
    Epstein, Eli
    Huse, Casey
    Link, Meredith
    Greenberg, Elliot
    PHYSICAL THERAPY IN SPORT, 2024, 67 : 104 - 109