Development and Reliability of a Visual-Cognitive Reactive Triple Hop Test

被引:2
|
作者
Farraye, Byrnadeen T. [1 ,2 ]
Simon, Janet E. [2 ,3 ]
Chaput, Meredith [1 ,2 ]
Kim, HoWon [1 ,2 ]
Monfort, Scott M. [4 ]
Grooms, Dustin R. [1 ,2 ,3 ]
机构
[1] Ohio Univ, Coll Hlth Sci & Profess, Sch Rehabil & Commun Sci, Div Phys Therapy, Athens, OH 45701 USA
[2] Ohio Univ, Ohio Musculoskeletal & Neurol Inst, Athens, OH 45701 USA
[3] Ohio Univ, Coll Hlth Sci & Profess, Sch Appl Hlth Sci & Wellness, Div Athlet Training, Athens, OH USA
[4] Montana State Univ, Dept Mech & Ind Engn, Bozeman, MT USA
基金
美国国家卫生研究院;
关键词
peripheral visual attention; visual working memory; lower-extremity; response inhibition; return to sport testing; TEST-RETEST RELIABILITY; ACL RECONSTRUCTION; NEUROCOGNITIVE FUNCTION; REACTION-TIME; INJURY RISK; DUAL-TASK; PERFORMANCE; STRENGTH; SPORTS;
D O I
10.1123/jsr.2022-0398
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Context: Current lower-extremity return to sport testing primarily considers the physical status of an athlete; however, sport participation requires continuous cognitive dual-task engagement. Therefore, the purpose was to develop and evaluate the reliability of a visual-cognitive reactive (VCR) triple hop test that simulates the typical sport demand of combined online visual cognitive processing and neuromuscular control to improve return to sport testing after lower-extremity injury. Design: Test- retest reliability. Methods: Twenty-one healthy college students (11 females, 23.5 [3.7] y, 1.73 [0.12] m, 73.0 [16.8] kg, Tegner Activity Scale 5.5 [1.1] points) participated. Participants performed a single-leg triple hop with and without a VCR dual task. The VCR task incorporated the FitLight system to challenge peripheral response inhibition and central working memory. Maximum hop distance, reaction time, cognitive errors, and physical errors were measured. Two identical testing visits were separated by 12 to 17 days (14 [1] d). Results: Traditional triple hop (intraclass correlation coefficients: ICC(3,1) = .96 [.91-.99]; standard error of the measurement = 16.99 cm) and the VCR triple hop (intraclass correlation coefficients(3,1) = .92 [.82-.97]; standard error of the measurement = 24.10 cm) both demonstrated excellent reliability for the maximum hop distance, and moderate reliability for the VCR triple hop reaction time (intraclass correlation coefficients(3,1) = .62 [.09-.84]; standard error of the measurement = 0.09 s). On average, the VCR triple hop resulted in a hop distance deficit of 8.17% (36.4 [5.1] cm; P < .05, d = 0.55) relative to the traditional triple hop. Conclusions: Hop distance on the VCR triple hop had excellent test-retest reliability and induced a significant physical performance deficit when compared with the traditional triple hop assessment. The VCR triple hop reaction time also demonstrated moderate reliability.
引用
收藏
页码:802 / 809
页数:8
相关论文
共 50 条
  • [31] Visual Sensory and Visual-Cognitive Function and Rate of Crash and Near-Crash Involvement Among Older Drivers Using Naturalistic Driving Data
    Huisingh, Carrie
    Levitan, Emily B.
    Irvin, Marguerite R.
    MacLennan, Paul
    Wadley, Virginia
    Owsley, Cynthia
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (07) : 2959 - 2967
  • [32] Validity and Reliability of the Test of Gross Motor Development-3 for children with visual impairments
    Brian, Ali
    Taunton, Sally A.
    Haibach-Beach, Pamela
    Lieberman, Lauren J.
    JOURNAL OF SPORT & EXERCISE PSYCHOLOGY, 2017, 39 : S53 - S53
  • [33] Reliability test target development
    Lu, MW
    Rudy, RJ
    ANNUAL RELIABILITY AND MAINTAINABILITY SYMPOSIUM - 2000 PROCEEDINGS, 2000, : 77 - 81
  • [34] Reliability test target development
    Lu, Ming-Wei
    Rudy, Richard J.
    Proceedings of the Annual Reliability and Maintainability Symposium, 2000, : 77 - 81
  • [35] Hop performance and leg muscle power in athletes: Reliability of a test battery
    Kockum, Britta
    Heijne, Annette I-L M.
    PHYSICAL THERAPY IN SPORT, 2015, 16 (03) : 222 - 227
  • [36] One-arm hop test: Reliability and effects of arm dominance
    Falsone, SA
    Gross, MT
    Guskiewicz, KM
    Schneider, RA
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2002, 32 (03): : 98 - 103
  • [37] VALIDITY AND RELIABILITY OF HOOPER VISUAL ORGANIZATION TEST
    GERSON, A
    PERCEPTUAL AND MOTOR SKILLS, 1974, 39 (01) : 95 - 100
  • [38] Key predictors of visual field test reliability
    Ho, Jason
    Ameen, Sally
    Crawley, Laura
    Normando, Eduardo
    Cordeiro, M. Francesca
    Bloom, Philip
    Ahmed, Faisal
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [39] Test-retest reliability of cognitive EEG
    McEvoy, LK
    Smith, ME
    Gevins, A
    CLINICAL NEUROPHYSIOLOGY, 2000, 111 (03) : 457 - 463
  • [40] Stabilometry and one-leg hop test have high test-retest reliability
    Ageberg, E
    Zatterstrom, R
    Moritz, U
    SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 1998, 8 (04) : 198 - 202