Failure Analysis of Heat Exchanger Using Eddy Current Testing (ECT)

被引:5
|
作者
Saffiudeen, Mohamed Fayas [1 ]
Syed, Abdullah [1 ]
Mohammed, Fasil T. [1 ]
机构
[1] Royal Commiss Jubail & Yanbu, Jubail Tech Inst, Dept Mech Skills, Jubail Ind City, Saudi Arabia
关键词
Heat exchanger; Tube inspection; Eddy current testing; Retubing; Maintenance; CORROSION; TUBE; INSPECTION; PERFORMANCE; EROSION; NDE;
D O I
10.1007/s11668-023-01746-0
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Shell and tube heat exchangers are widely used in the oil and gas, petrochemical and nuclear power sectors. The most important aspect of the turnaround is the routine testing and inspection of the in-service heat exchanger. Heat exchangers in use are the primary cause of tube flaws such as pitting, corrosion, erosion, fretting corrosion, crevice corrosion, stress corrosion cracking, wear, galvanic corrosion, fatigue cracking, microbiologically influenced corrosion, and so forth. For research, a seamless nickel-iron-chromium alloy-tubed SB 163 (UNS 8810) heat exchanger was taken. The total number of tubes that need to be inspected is 286 tubes with a specification of 19.05 mm OD x 2.11 mm thickness x 5000 mm length. From the different advanced NDT techniques, the eddy current testing (ECT) was chosen for inspection since it has become one of the most popular NDT methods for locating discontinuities in heat exchanger tubes. A standard calibration tube was used to calibrate the system's response and set the sensitivity. During the inspection, the ECT probe was inserted from the below side up to the other end and collected while pulling the probe from the tube. Inspection data were recorded for the length of each tube. All indications were assessed, and defects were categorized as different extents of wall thickness loss after inspection. The inspection report shows how many tubes were found defective and need to be plugged or removed (retubing). From the inspection data (the result of statistics), defects like corrosion, pitting, wall loss, wear, etc., that resulted in notable material loss were identified. Inspection data also summarized where the defects were located (like between the first baffle and the second baffle) and are helpful for further research. After analysis using ECT reports, the defective tubes were categorized according to their defect percentage and location, which helps to do retubing effectively by avoiding the 100% retubing concept.
引用
收藏
页码:1898 / 1906
页数:9
相关论文
共 50 条
  • [31] Equivalent circuit analysis and demonstration of eddy current testing using resonance
    Kobayashi, N. (noriyasu.kobayashi@toshiba.co.jp), 1600, Institute of Electrical Engineers of Japan (134):
  • [32] Applying computer modeling to eddy current signal analysis for steam generator and heat exchanger tube inspections
    Sullivan, SP
    Cecco, VS
    Carter, JR
    Spanner, M
    McElvanney, M
    Krause, TW
    Tkaczyk, R
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 19A AND 19B, 2000, 509 : 401 - 408
  • [33] Identification of flaws using eddy current testing
    Electrical Engineering Department, Technical University of Szczecin, Szczecin, Poland
    COMPEL Int J Comput Math Electr Electron Eng, 4 (516-527):
  • [34] SEMI-AUTOMATED EDDY CURRENT SYSTEM FOR HEAT EXCHANGER INSPECTION.
    SHARP, F.L.
    1982,
  • [35] Application of model based inversion to eddy current NDT of heat exchanger tubing
    Sabbagh, Harold A.
    Murphy, R. Kim
    Sabbagh, Elias H.
    Aldrin, John C.
    MATERIALS EVALUATION, 2008, 66 (07) : 764 - 774
  • [36] Transmit receive eddy current probes for circumferential cracks in heat exchanger tubes
    Obrutsky, LS
    Cecco, VS
    Sullivan, SP
    Humphrey, D
    MATERIALS EVALUATION, 1996, 54 (01) : 93 - 98
  • [37] Identification of flaws using eddy current testing
    Sikora, R
    Chady, T
    Gratkowski, S
    Komorowski, M
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 1998, 17 (04) : 516 - +
  • [38] Improved detection performance using a multi-frequency method of eddy current testing for outside circumferential cracks near an expansion of heat exchanger tubes
    Narishige, S.
    Nishimizu, A.
    Koike, M.
    Abe, Y.
    Narumi, Y.
    Tsuge, T.
    INSIGHT, 2010, 52 (06) : 298 - 301
  • [39] Numerical analysis of eddy current testing probe
    Tsuboi, H
    Ikeda, K
    Kobayashi, F
    Misaki, T
    ELECTROMAGNETIC NONDESTRUCTIVE EVALUATION, 1997, 12 : 67 - 72
  • [40] Failure analysis of brass tubes of a heat exchanger
    Grzegorzewicz, T
    Kuznicka, B
    PRAKTISCHE METALLOGRAPHIE-PRACTICAL METALLOGRAPHY, 1998, 35 (03): : 148 - 155