Fast and Environmentally Friendly Method for Simultaneous Determination of Hydrochlorothiazide, Losartan and Potassium by Capillary Electrophoresis with Capacitively Coupled Contactless Conductivity Detection
被引:3
|
作者:
Marra, Mariana C.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Fed Uberlandia, Inst Quim, Ave Joao Naves Avila 2121, BR-38400902 Uberlandia, MG, BrazilUniv Fed Uberlandia, Inst Quim, Ave Joao Naves Avila 2121, BR-38400902 Uberlandia, MG, Brazil
Marra, Mariana C.
[1
]
Ribeiro, Michelle M. A. C.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Fed Uberlandia, Inst Quim, Ave Joao Naves Avila 2121, BR-38400902 Uberlandia, MG, BrazilUniv Fed Uberlandia, Inst Quim, Ave Joao Naves Avila 2121, BR-38400902 Uberlandia, MG, Brazil
Ribeiro, Michelle M. A. C.
[1
]
Munoz, Rodrigo A. A.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Fed Uberlandia, Inst Quim, Ave Joao Naves Avila 2121, BR-38400902 Uberlandia, MG, Brazil
Inst Nacl Ciencia & Tecnol Bioanalit, BR-13083861 Campinas, SP, BrazilUniv Fed Uberlandia, Inst Quim, Ave Joao Naves Avila 2121, BR-38400902 Uberlandia, MG, Brazil
Munoz, Rodrigo A. A.
[1
,2
]
Richter, Eduardo M.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Fed Uberlandia, Inst Quim, Ave Joao Naves Avila 2121, BR-38400902 Uberlandia, MG, Brazil
Inst Nacl Ciencia & Tecnol Bioanalit, BR-13083861 Campinas, SP, BrazilUniv Fed Uberlandia, Inst Quim, Ave Joao Naves Avila 2121, BR-38400902 Uberlandia, MG, Brazil
Richter, Eduardo M.
[1
,2
]
机构:
[1] Univ Fed Uberlandia, Inst Quim, Ave Joao Naves Avila 2121, BR-38400902 Uberlandia, MG, Brazil
Losartan potassium and hydrochlorothiazide are often combined in pharmaceutical formulations for the treatment of hypertension. Therefore, the determination of these compounds in a single run is highly desirable for rapid quality control applications. The present study describes an ultra-fast (ca. 85 injections h(-1)) and environmentally friendly method based on capillary electrophoresis (CE) with capacitively coupled contactless conductivity detection for simultaneous quantification of potassium, losartan and hydrochlorothiazide. Cation (potassium) and anions (losartan and hydrochlorothiazide) were analyzed in a single run using a background electrolyte composed by 10.0 mmol L-1 boric acid (pH = 9.0, adjusted with sodium hydroxide). The limits of detection were 4.0, 3.0 and 10.0 mu mol L-1 for potassium, losartan and hydrochlorothiazide, respectively. The proposed method is simple, fast, with minimal waste generation, and accurate (recovery values between 98 and 102%). The results obtained with the CE method were statistically similar (95% confidence level) to those obtained by high-performance liquid chromatography (losartan and hydrochlorothiazide) and flame photometry (potassium).
机构:
King Faisal Univ, Coll Sci, Dept Chem, Al Hufuf 31982, Al Ahsa, Saudi Arabia
Univ Khartoum, Fac Sci, Dept Chem, Khartoum, SudanKing Faisal Univ, Coll Sci, Dept Chem, Al Hufuf 31982, Al Ahsa, Saudi Arabia
Elbashir, Abdalla A.
Osman, Abdelbagi
论文数: 0引用数: 0
h-index: 0
机构:
Najran Univ, Coll Engn, Dept Chem Engn, Najran, Saudi ArabiaKing Faisal Univ, Coll Sci, Dept Chem, Al Hufuf 31982, Al Ahsa, Saudi Arabia
Osman, Abdelbagi
Elawad, Mohammed
论文数: 0引用数: 0
h-index: 0
机构:
Omdurman Islamic Univ, Fac Sci, Dept Chem, Omdurman, SudanKing Faisal Univ, Coll Sci, Dept Chem, Al Hufuf 31982, Al Ahsa, Saudi Arabia
Elawad, Mohammed
Ziyada, Abobakr K.
论文数: 0引用数: 0
h-index: 0
机构:
Jubail Ind Coll, Dept Gen Studies, Jubail Ind City, Saudi ArabiaKing Faisal Univ, Coll Sci, Dept Chem, Al Hufuf 31982, Al Ahsa, Saudi Arabia
Ziyada, Abobakr K.
Aboul-Enein, Hassan Y.
论文数: 0引用数: 0
h-index: 0
机构:
Natl Res Ctr, Pharmaceut & Med Chem Dept, Div Pharmaceut & Drug Ind Res Div, Cairo 12622, EgyptKing Faisal Univ, Coll Sci, Dept Chem, Al Hufuf 31982, Al Ahsa, Saudi Arabia