Fast and Environmentally Friendly Method for Simultaneous Determination of Hydrochlorothiazide, Losartan and Potassium by Capillary Electrophoresis with Capacitively Coupled Contactless Conductivity Detection

被引:3
|
作者
Marra, Mariana C. [1 ]
Ribeiro, Michelle M. A. C. [1 ]
Munoz, Rodrigo A. A. [1 ,2 ]
Richter, Eduardo M. [1 ,2 ]
机构
[1] Univ Fed Uberlandia, Inst Quim, Ave Joao Naves Avila 2121, BR-38400902 Uberlandia, MG, Brazil
[2] Inst Nacl Ciencia & Tecnol Bioanalit, BR-13083861 Campinas, SP, Brazil
关键词
minimal waste; pharmaceutical analysis; stoichiometry ratio; sub minute analysis; tablets; TABLETS; CATIONS; ANIONS;
D O I
10.21577/0103-5053.20230033
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Losartan potassium and hydrochlorothiazide are often combined in pharmaceutical formulations for the treatment of hypertension. Therefore, the determination of these compounds in a single run is highly desirable for rapid quality control applications. The present study describes an ultra-fast (ca. 85 injections h(-1)) and environmentally friendly method based on capillary electrophoresis (CE) with capacitively coupled contactless conductivity detection for simultaneous quantification of potassium, losartan and hydrochlorothiazide. Cation (potassium) and anions (losartan and hydrochlorothiazide) were analyzed in a single run using a background electrolyte composed by 10.0 mmol L-1 boric acid (pH = 9.0, adjusted with sodium hydroxide). The limits of detection were 4.0, 3.0 and 10.0 mu mol L-1 for potassium, losartan and hydrochlorothiazide, respectively. The proposed method is simple, fast, with minimal waste generation, and accurate (recovery values between 98 and 102%). The results obtained with the CE method were statistically similar (95% confidence level) to those obtained by high-performance liquid chromatography (losartan and hydrochlorothiazide) and flame photometry (potassium).
引用
收藏
页码:1208 / 1213
页数:6
相关论文
共 50 条
  • [21] Determination of Biogenic Amines in Seawater Using Capillary Electrophoresis with Capacitively Coupled Contactless Conductivity Detection
    Gubartallah, Elbaleeq A.
    Makahleh, Ahmad
    Quirino, Joselito P.
    Saad, Bahruddin
    MOLECULES, 2018, 23 (05):
  • [22] Determination of pharmaceuticals identified as emerging pollutants by capillary electrophoresis with capacitively coupled contactless conductivity detection
    Li, Sam F. Y.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2009, 237
  • [23] Simultaneous determination of inorganic cations and anions by dual opposite ends injection coupled with capillary electrophoresis with capacitively contactless conductivity detection
    Tan, F
    Yang, BC
    Guan, YF
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (03) : 313 - 316
  • [24] Fast determination of cocaine and some common adulterants in seized cocaine samples by capillary electrophoresis with capacitively coupled contactless conductivity detection
    Marra, Mariana C.
    de Castro Costa, Brenda M.
    Munoz, Rodrigo A. A.
    Santana, Mario H. P.
    Maldaner, Adriano O.
    Botelho, Elvio D.
    Coltro, Wendell K. T.
    Richter, Eduardo M.
    ANALYTICAL METHODS, 2018, 10 (24) : 2875 - 2880
  • [25] Trace determination of perchlorate using electromembrane extraction and capillary electrophoresis with capacitively coupled contactless conductivity detection
    Kiplagat, Isaac K.
    Thi Kieu Oanh Doan
    Kuban, Pavel
    Bocek, Petr
    ELECTROPHORESIS, 2011, 32 (21) : 3008 - 3015
  • [26] Determination of Metal Ions and Melamine in Milk by Capillary Electrophoresis- Capacitively Coupled Contactless Conductivity Detection
    Zhang Chen-Ling
    Tian Jing
    Qin Wei-Dong
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (10) : 1497 - 1500
  • [27] Determination of muscle relaxants pancuronium and vecuronium bromide by capillary electrophoresis with capacitively coupled contactless conductivity detection
    Petru, Klara
    Jac, Paval
    Luzova, Veronika
    Kunes, Jiri
    Polasek, Miroslav
    ELECTROPHORESIS, 2011, 32 (08) : 890 - 895
  • [28] Determination of pharmaceuticals classified as emerging pollutants using capillary electrophoresis with capacitively coupled contactless conductivity detection
    Quek, Ngee Mien
    Law, Wai Siang
    Lau, Hiu Fung
    Zhao, Jian Hong
    Hauser, Peter C.
    Li, Sam Fong Yau
    ELECTROPHORESIS, 2008, 29 (17) : 3701 - 3709
  • [29] Integrated Capacitively Coupled Contactless Conductivity Detector for Capillary Electrophoresis
    Wang Lixin
    Fu Chonggang
    PROCEEDINGS OF THE SECOND INTERNATIONAL SYMPOSIUM ON TEST AUTOMATION & INSTRUMENTATION, VOL. 3, 2008, : 1493 - 1495
  • [30] Determination of vitamin C and preservatives in beverages by conventional capillary electrophoresis and microchip electrophoresis with capacitively coupled contactless conductivity detection
    Law, WS
    Kubán, P
    Zha, JH
    Li, SFY
    Hauser, PC
    ELECTROPHORESIS, 2005, 26 (24) : 4648 - 4655