Detection of Acute Optic Neuritis using Contrast-Enhanced 3-Dimensional Cube T1-Weighted Imaging: A Preliminary Study

被引:1
|
作者
Yang, Renjie [1 ]
Qu, Bing [2 ]
Liu, Weiyin Vivian [3 ]
Liu, Changsheng [1 ]
Chen, Ting [4 ]
Li, Liang [1 ]
Zha, Yunfei [1 ]
机构
[1] Wuhan Univ, Renmin Hosp, Dept Radiol, Wuhan 430060, Hubei, Peoples R China
[2] Wuhan Univ, Renmin Hosp, Dept Gen Surg, Wuhan 430060, Hubei, Peoples R China
[3] GE Healthcare, MR Res, Beijing 100080, Peoples R China
[4] Wuhan Univ, Renmin Hosp, Dept Ophthalmol, Wuhan 430060, Hubei, Peoples R China
基金
中国国家自然科学基金;
关键词
Magnetic resonance imaging; cube; variable flip angle; 3-dimensional fast spin echo; optic neuritis; whole-brain imaging; LONG ECHO TRAINS; NERVE; RESOLUTION;
D O I
10.2174/1386207325666220823121312
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Objective We aimed to assess whole-brain imaging with contrast-enhanced (CE) 3-dimensional (3D) Cube T1WI in improving the diagnostic accuracy of acute optic neuritis (ON) compared to conventional CE 2-dimensional (2D) T1WI. Methods At a field strength of 3 T, CE 3D Cube T1-weighted and conventional CE 2D T1-weighted MR images were retrospectively analyzed for 32 patients (64 optic nerves) with clinically confirmed acute ON. The study cohort included 36 pathological nerves. Image assessments including the overall image quality, clarity of the optic nerve, and visual contrast enhancement were performed by two blinded neuroradiologists using a 4-point scale. The sensitivity, specificity, and accuracy of the conventional 2D T1WI and 3D Cube T1WI were calculated according to the clinical diagnosis. Results The application of 3D Cube T1WI improved the overall image quality compared to 2D Ax T1WI and 2D Cor T1WI (P < 0.05). The clarity of the optic nerve and the visual contrast enhancement were higher for the 3D Cube T1WI compared to the 2D Ax T1WI and 2D Cor T1WI for at least one reader. The sensitivity, specificity, and accuracy were 89%, 86%, 88% for the 3D Cube T1WI respectively, and 75%, 79%, 77% for the conventional 2D T1WI respectively. The lesions detected by the conventional 2D T1WI were all detected by the 3D Cube T1WI. Conclusion Our data show that whole-brain imaging with CE 3D Cube T1WI is a viable alternative for the detection of acute ON without sacrificing scanning efficiency.
引用
收藏
页码:1480 / 1487
页数:8
相关论文
共 50 条
  • [41] T1-Weighted Contrast-Enhanced Magnetic Resonance Imaging of the Small Bowel Comparison Between 1.5 and 7 T
    Hahnemann, Maria L.
    Kraff, Oliver
    Orzada, Stephan
    Umutlu, Lale
    Kinner, Sonja
    Ladd, Mark E.
    Quick, Harald H.
    Lauenstein, Thomas C.
    INVESTIGATIVE RADIOLOGY, 2015, 50 (08) : 539 - 547
  • [42] Is there a need for contrast-enhanced T1-weighted MRI of the spine after inconspicuous short T inversion recovery imaging?
    Mahnken, AH
    Wildberger, JE
    Adam, G
    Stanzel, S
    Schmitz-Rode, T
    Günther, RW
    Buecker, A
    EUROPEAN RADIOLOGY, 2005, 15 (07) : 1387 - 1392
  • [43] Prediction of High-Grade Pediatric Meningiomas: Magnetic Resonance Imaging Features Based on T1-Weighted, T2-Weighted, and Contrast-Enhanced T1-Weighted Images
    Li, Hao
    Zhao, Meng
    Jiao, Yuming
    Ge, Peicong
    Li, Zhicen
    Ma, Ji
    Wang, Shuo
    Cao, Yong
    Zhao, Jizong
    WORLD NEUROSURGERY, 2016, 91 : 89 - 95
  • [44] MR imaging of osteomyelitis in diabetic feet: Relative conspicuousness on T1-weighted T2-weighted, STIR, and contrast-enhanced fat-suppressed T1-weighted images
    Judkiewicz, AM
    Colon, E
    Jelinek, JS
    Clement, S
    RADIOLOGY, 1996, 201 : 1440 - 1440
  • [45] Algorithms for calculation of kinetic parameters from T1-weighted dynamic contrast-enhanced magnetic resonance imaging
    Horsfield, MA
    Morgan, B
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (04) : 723 - 729
  • [46] FULLY AUTOMATIC MENINGIOMA SEGMENTATION USING T1-WEIGHTED CONTRAST-ENHANCED MR IMAGES ONLY
    Boelders, S. M.
    De Baene, W.
    Rutten, G. J. M.
    Gehring, K.
    Ong, L. L.
    NEURO-ONCOLOGY, 2022, 24
  • [47] Is there a need for contrast-enhanced T1-weighted MRI of the spine after inconspicuous short τ inversion recovery imaging?
    Andreas H. Mahnken
    Joachim E. Wildberger
    Gerhard Adam
    Sven Stanzel
    Thomas Schmitz-Rode
    Rolf W. Günther
    Arno Buecker
    European Radiology, 2005, 15 : 1387 - 1392
  • [48] Usefulness of a Combined Approach of T1-Weighted, T2-Weighted, Dynamic Contrast-Enhanced, and Diffusion-Weighted Imaging in Prostate Cancer
    Dal Min, Byung
    Kim, Won Tae
    Cho, Bum Sang
    Kim, Yong-June
    Yun, Seok Joong
    Lee, Sang-Cheol
    Kim, Wun-Jae
    KOREAN JOURNAL OF UROLOGY, 2012, 53 (12) : 830 - 835
  • [49] Characteristics of false positive lesions appeared in dynamic contrast-enhanced t1-weighted MR imaging of the breast
    Sawai, Y
    Arisawa, J
    Inaji, H
    Koyama, H
    Kasugai, T
    Ishiguro, S
    EUROPEAN JOURNAL OF CANCER, 2002, 38 : S143 - S143
  • [50] Detection of small brain metastases at 3 T: comparing the diagnostic performances of contrast-enhanced T1-weighted SPACE, MPRAGE, and 2D FLASH imaging
    Kwak, Hyo-Sung
    Hwang, Seungbae
    Chung, Gyung-Ho
    Song, Ji-Soo
    Choi, Eun-Jung
    CLINICAL IMAGING, 2015, 39 (04) : 571 - 575