Detection of Acute Optic Neuritis using Contrast-Enhanced 3-Dimensional Cube T1-Weighted Imaging: A Preliminary Study

被引:1
|
作者
Yang, Renjie [1 ]
Qu, Bing [2 ]
Liu, Weiyin Vivian [3 ]
Liu, Changsheng [1 ]
Chen, Ting [4 ]
Li, Liang [1 ]
Zha, Yunfei [1 ]
机构
[1] Wuhan Univ, Renmin Hosp, Dept Radiol, Wuhan 430060, Hubei, Peoples R China
[2] Wuhan Univ, Renmin Hosp, Dept Gen Surg, Wuhan 430060, Hubei, Peoples R China
[3] GE Healthcare, MR Res, Beijing 100080, Peoples R China
[4] Wuhan Univ, Renmin Hosp, Dept Ophthalmol, Wuhan 430060, Hubei, Peoples R China
基金
中国国家自然科学基金;
关键词
Magnetic resonance imaging; cube; variable flip angle; 3-dimensional fast spin echo; optic neuritis; whole-brain imaging; LONG ECHO TRAINS; NERVE; RESOLUTION;
D O I
10.2174/1386207325666220823121312
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Objective We aimed to assess whole-brain imaging with contrast-enhanced (CE) 3-dimensional (3D) Cube T1WI in improving the diagnostic accuracy of acute optic neuritis (ON) compared to conventional CE 2-dimensional (2D) T1WI. Methods At a field strength of 3 T, CE 3D Cube T1-weighted and conventional CE 2D T1-weighted MR images were retrospectively analyzed for 32 patients (64 optic nerves) with clinically confirmed acute ON. The study cohort included 36 pathological nerves. Image assessments including the overall image quality, clarity of the optic nerve, and visual contrast enhancement were performed by two blinded neuroradiologists using a 4-point scale. The sensitivity, specificity, and accuracy of the conventional 2D T1WI and 3D Cube T1WI were calculated according to the clinical diagnosis. Results The application of 3D Cube T1WI improved the overall image quality compared to 2D Ax T1WI and 2D Cor T1WI (P < 0.05). The clarity of the optic nerve and the visual contrast enhancement were higher for the 3D Cube T1WI compared to the 2D Ax T1WI and 2D Cor T1WI for at least one reader. The sensitivity, specificity, and accuracy were 89%, 86%, 88% for the 3D Cube T1WI respectively, and 75%, 79%, 77% for the conventional 2D T1WI respectively. The lesions detected by the conventional 2D T1WI were all detected by the 3D Cube T1WI. Conclusion Our data show that whole-brain imaging with CE 3D Cube T1WI is a viable alternative for the detection of acute ON without sacrificing scanning efficiency.
引用
收藏
页码:1480 / 1487
页数:8
相关论文
共 50 条
  • [21] Efficient method for calculating kinetic parameters using T1-weighted dynamic contrast-enhanced magnetic resonance imaging
    Murase, K
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (04) : 858 - 862
  • [22] Contrast-enhanced fluid-attenuated inversion recovery vs. contrast-enhanced spin echo T1-weighted brain imaging
    Falzone, Cristian
    Rossi, Federica
    Calistri, Maurizio
    Tranquillo, Massimo
    Baroni, Massimo
    VETERINARY RADIOLOGY & ULTRASOUND, 2008, 49 (04) : 333 - 338
  • [23] AUTOMATED VOLUMETRY OF MENINGIOMAS IN CONTRAST-ENHANCED T1-WEIGHTED MRI USING DEEP LEARNING
    Hirayama, Ryuichi
    Iwata, Takamitsu
    Yamada, Shuhei
    Yokota, Chisato
    Kijima, Noriyuki
    Kishima, Haruhiko
    NEURO-ONCOLOGY, 2024, 26
  • [24] Uncertainty in the analysis of tracer kinetics using dynamic contrast-enhanced T1-weighted MRI
    Buckley, DL
    MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (03) : 601 - 606
  • [25] Subependymal Giant Cell Astrocytoma Size Measurement in Tuberous Sclerosis Complex: Noncontrast vs Contrast-Enhanced 3-Dimensional T1-Weighted Magnetic Resonance Imaging (MRI)
    Hill, Brook J.
    Gadde, Judith A.
    Palasis, Susan
    JOURNAL OF CHILD NEUROLOGY, 2019, 34 (14) : 922 - 927
  • [26] Evaluation of the clinical utility of maximum intensity projections of3D contrast-enhanced,T1-weighted imaging for the detection of brain metastases
    Hainc, Nicolin
    Federau, Christian
    Tyndall, Anthony
    Mittermeier, Andreas
    Bink, Andrea
    Stippich, Christoph
    Schubert, Tilman
    CANCER REPORTS, 2020, 3 (05)
  • [27] Automated volumetry of meningiomas in contrast-enhanced T1-Weighted MRI using deep learning
    Iwata, Takamitsu
    Hirayama, Ryuichi
    Yamada, Shuhei
    Kijima, Noriyuki
    Okita, Yoshiko
    Kagawa, Naoki
    Kishima, Haruhiko
    WORLD NEUROSURGERY-X, 2024, 22
  • [28] Augmented networks for faster brain metastases detection in T1-weighted contrast-enhanced 3D MRI
    Dikici, Engin
    V. Nguyen, Xuan
    Bigelow, Matthew
    Prevedello, Luciano M.
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2022, 98
  • [29] Contrast-Enhanced Myocardial T1-Weighted Scout (Look-Locker) Imaging for the Detection of Myocardial Damages in Hypertrophic Cardiomyopathy
    Amano, Yasuo
    Takayama, Morimasa
    Kumita, Shinichiro
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (04) : 778 - 784
  • [30] Perfusion Estimation Using Contrast-Enhanced 3-dimensional Subharmonic Ultrasound Imaging An In Vivo Study
    Sridharan, Anush
    Eisenbrey, John R.
    Liu, Ji-Bin
    Machado, Priscilla
    Halldorsdottir, Valgerdur G.
    Dave, Jaydev K.
    Zhao, Hongjia
    He, Yu
    Park, Suhyun
    Dianis, Scott
    Wallace, Kirk
    Thomenius, Kai E.
    Forsberg, Flemming
    INVESTIGATIVE RADIOLOGY, 2013, 48 (09) : 654 - 660