Development of Semi-continuous Measurement System for Atmospheric HNO3

被引:1
|
作者
Hwang, Jihyun [1 ]
Kang, Seokwon [1 ]
Kim, Kyunghoon [1 ]
Park, Taehyun [1 ]
Ban, Jihee [1 ]
Song, Jeongin [1 ]
Park, Inseon [1 ]
Shin, Hye-Jung [2 ]
Jung, Hae-Jin [2 ]
Kang, Gong-Unn [3 ]
Bae, Min-Suk [4 ]
Lee, Kwon-Ho [5 ]
Lee, Taehyoung [1 ]
机构
[1] Hankuk Univ Foreign Studies, Dept Environm Sci, Yongin, South Korea
[2] Natl Inst Environm Res, Climate & Air Qual Res Dept, Air Qual Res Div, Incheon, South Korea
[3] Wonkwang Hlth Sci Univ, Dept Med Adm, Iksan, South Korea
[4] Mokpo Natl Univ, Dept Environm Engn, Muan, South Korea
[5] Gangneung Wonju Natl Univ, Dept Atmospher & Environm Sci, Kangnung, South Korea
关键词
Nitric acid; Semi-continuous measurement; Nitric dioxide; Ion chromatography; AMBIENT AIR; PM2.5; AEROSOLS; GASES; SO2; HCL;
D O I
10.5572/KOSAE.2023.39.2.265
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
Nitric acid (HNO3) is formed to ammonium nitrate (NH4NO3) of secondary aerosols by the photochemical reaction. A semi-continuous HNO3 measurement system was developed for the concentration of HNO3 in the atmosphere through ion chromatography after it is sufficiently absorbed by deionized water. In order to correct the Nitrate (NO3-) concentration, an experiment was conducted to simulate the concentration of atmospheric nitrogen dioxide (NO2) and hydrogen peroxide (H2O2) which produce additional NO3-. To evaluate the performance of the instrument, it compared the denuder method, Vocus PTR-TOF (Vocus proton-transfer-reaction time-of-flight mass spectrometer), and semi-continuous HNO3 measurement systems at high concentrations of HNO3 using a standard gas. In addition, an experiment to measure HNO3 in the atmosphere was conducted using both the denuder method and the semi-continuous HNO3 system. The concentration of HNO3 additionally generated by H2O2 and NO2 inside the measurement system was measured lower than the detection limit of the previously performed QC/QA, indicating that it was suitable for measuring HNO3. In the comparison experiment between the different equipment using a standard HNO3 gas, a difference of 4.7% to 8.4% was observed, demonstrating that the results of HNO3 concentration measurements were similar. When measuring HNO3 in the air, the comparison experiment between the semi-continuous HNO3 system and the denuder method showed a high correlation with a coefficient of about 0.98 and a difference of only 0.2%. The semi-continuous HNO3 measuring system was found to be hardly impacted by interference from other materials in the sample and produced results that were similar measured values to using other equipment. Also, it is easy to analyze the concentration and chemical properties of HNO3 during the measurement period because the data is acquired in real-time.
引用
收藏
页码:265 / 277
页数:13
相关论文
共 50 条
  • [31] THE AL/HNO3, HCL/C SYSTEM AT NEGATIVE TEMPERATURES
    FINAENOV, AI
    POPOVA, SS
    JOURNAL OF APPLIED CHEMISTRY OF THE USSR, 1990, 63 (11): : 2378 - 2380
  • [32] Measurements of concentration gradients of HNO2 and HNO3 over a semi-natural ecosystem: Discussion
    Harrison, RM
    Peak, JD
    ATMOSPHERIC ENVIRONMENT, 1997, 31 (17) : 2891 - 2892
  • [33] A compact semi-continuous atmospheric aerosol sampler for elemental analysis: a preliminary result
    Lee, Dong Soo
    Lee, Bokyoung
    Eom, Ji Won
    ATMOSPHERIC POLLUTION RESEARCH, 2011, 2 (04) : 506 - 512
  • [34] Model-Guided Development of a Semi-Continuous Drying Process
    Anthony Grelier
    Matej Zadravec
    Johan Remmelgas
    Thomas Forgber
    Franco Colacino
    Gabrielle Pilcer
    Fanny Stauffer
    Theresa Hörmann-Kincses
    Pharmaceutical Research, 2022, 39 : 2005 - 2016
  • [35] DEVELOPMENT OF A PROCESS FOR SEMI-CONTINUOUS CASTING OF ROLLING MILL ROLLS
    FILIPPOV, AS
    VETROV, BG
    KORNIENK.OA
    BELOUSOV, LA
    STAL IN ENGLISH-USSR, 1966, (07): : 580 - &
  • [36] Model-Guided Development of a Semi-Continuous Drying Process
    Grelier, Anthony
    Zadravec, Matej
    Remmelgas, Johan
    Forgber, Thomas
    Colacino, Franco
    Pilcer, Gabrielle
    Stauffer, Fanny
    Hoermann-Kincses, Theresa
    PHARMACEUTICAL RESEARCH, 2022, 39 (09) : 2005 - 2016
  • [37] Demonstration of nonlinear absorption in Au semi-continuous film by electrical measurement
    Yajadda, M. M. A.
    Farrant, D. I.
    Levchenko, I.
    Mueller, K. -H.
    Ostrikov, K.
    OPTICS EXPRESS, 2011, 19 (18): : 17167 - 17172
  • [38] Generation of HNO2 by bubbling NO in HNO3 system and its application in the PUREX process
    Zhu Zhaowu
    He Jianyu
    Zhang Zefu
    Zhao Zhiqiang
    Journal of Radioanalytical and Nuclear Chemistry, 2003, 258 (3) : 557 - 561
  • [39] Generation of HNO2 by bubbling NO in HNO3 system and its application in the PUREX process
    Zhu, ZW
    He, JY
    Zhang, ZF
    Zhao, ZQ
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2003, 258 (03) : 557 - 561
  • [40] Operation-aided system for fault diagnosis of continuous and semi-continuous processes
    Nam, DS
    Jeong, CW
    Choe, YJ
    Yoon, ES
    COMPUTERS & CHEMICAL ENGINEERING, 1996, 20 (6-7) : 793 - 803