Development of Semi-continuous Measurement System for Atmospheric HNO3

被引:1
|
作者
Hwang, Jihyun [1 ]
Kang, Seokwon [1 ]
Kim, Kyunghoon [1 ]
Park, Taehyun [1 ]
Ban, Jihee [1 ]
Song, Jeongin [1 ]
Park, Inseon [1 ]
Shin, Hye-Jung [2 ]
Jung, Hae-Jin [2 ]
Kang, Gong-Unn [3 ]
Bae, Min-Suk [4 ]
Lee, Kwon-Ho [5 ]
Lee, Taehyoung [1 ]
机构
[1] Hankuk Univ Foreign Studies, Dept Environm Sci, Yongin, South Korea
[2] Natl Inst Environm Res, Climate & Air Qual Res Dept, Air Qual Res Div, Incheon, South Korea
[3] Wonkwang Hlth Sci Univ, Dept Med Adm, Iksan, South Korea
[4] Mokpo Natl Univ, Dept Environm Engn, Muan, South Korea
[5] Gangneung Wonju Natl Univ, Dept Atmospher & Environm Sci, Kangnung, South Korea
关键词
Nitric acid; Semi-continuous measurement; Nitric dioxide; Ion chromatography; AMBIENT AIR; PM2.5; AEROSOLS; GASES; SO2; HCL;
D O I
10.5572/KOSAE.2023.39.2.265
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
Nitric acid (HNO3) is formed to ammonium nitrate (NH4NO3) of secondary aerosols by the photochemical reaction. A semi-continuous HNO3 measurement system was developed for the concentration of HNO3 in the atmosphere through ion chromatography after it is sufficiently absorbed by deionized water. In order to correct the Nitrate (NO3-) concentration, an experiment was conducted to simulate the concentration of atmospheric nitrogen dioxide (NO2) and hydrogen peroxide (H2O2) which produce additional NO3-. To evaluate the performance of the instrument, it compared the denuder method, Vocus PTR-TOF (Vocus proton-transfer-reaction time-of-flight mass spectrometer), and semi-continuous HNO3 measurement systems at high concentrations of HNO3 using a standard gas. In addition, an experiment to measure HNO3 in the atmosphere was conducted using both the denuder method and the semi-continuous HNO3 system. The concentration of HNO3 additionally generated by H2O2 and NO2 inside the measurement system was measured lower than the detection limit of the previously performed QC/QA, indicating that it was suitable for measuring HNO3. In the comparison experiment between the different equipment using a standard HNO3 gas, a difference of 4.7% to 8.4% was observed, demonstrating that the results of HNO3 concentration measurements were similar. When measuring HNO3 in the air, the comparison experiment between the semi-continuous HNO3 system and the denuder method showed a high correlation with a coefficient of about 0.98 and a difference of only 0.2%. The semi-continuous HNO3 measuring system was found to be hardly impacted by interference from other materials in the sample and produced results that were similar measured values to using other equipment. Also, it is easy to analyze the concentration and chemical properties of HNO3 during the measurement period because the data is acquired in real-time.
引用
收藏
页码:265 / 277
页数:13
相关论文
共 50 条
  • [21] VALIDATION OF TECHNIQUES FOR FAST-RESPONSE MEASUREMENT OF HNO3 AND NH3 AND DETERMINATION OF THE [NH3] [HNO3] CONCENTRATION PRODUCT
    HARRISON, RM
    MSIBI, IM
    ATMOSPHERIC ENVIRONMENT, 1994, 28 (02) : 247 - 255
  • [22] Automated aerosol Raman spectrometer for semi-continuous sampling of atmospheric aerosol
    Doughty, David C.
    Hill, Steven C.
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2017, 188 : 103 - 117
  • [23] Measurements of concentration gradients of HNO2 and HNO3 over a semi-natural ecosystem
    Neftel, A
    Blatter, A
    Hesterberg, R
    Staffelbach, T
    ATMOSPHERIC ENVIRONMENT, 1996, 30 (17) : 3017 - 3025
  • [24] A semi-continuous system for monitoring microbially influenced corrosion
    Eid, Mary M.
    Duncan, Kathleen E.
    Tanner, Ralph S.
    JOURNAL OF MICROBIOLOGICAL METHODS, 2018, 150 : 55 - 60
  • [25] Semi-continuous measurement of chromophoric organic aerosols using the PILS-EEM-TOC system
    Chen, Qingcai
    Hua, Xiaoyu
    Wang, Yuqin
    Zhang, Lixin
    Chang, Tian
    ATMOSPHERIC ENVIRONMENT, 2021, 244 (244)
  • [26] Validation of HNO3 spectroscopic parameters using atmospheric absorption and emission measurements
    Tran, H.
    Brizzi, G.
    Gomez, L.
    Perrin, A.
    Hase, F.
    Ridolfi, M.
    Hartmann, J. -M.
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2009, 110 (1-2): : 109 - 117
  • [27] LABORATORY AND ATMOSPHERIC MEASUREMENTS OF HNO3 TO DETERMINE THE AMOUNT OF THIS CONSTITUENT IN THE EARTHS ATMOSPHERE
    LADOBORDOWSKY, O
    AMAT, G
    APPLIED OPTICS, 1979, 18 (20): : 3400 - 3403
  • [28] Sensitivity of washout on HNO3/NOx ratio in atmospheric chemistry transport models
    Velders, GJM
    Granier, C
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2001, 106 (D3): : 3125 - 3132
  • [29] Emission Characteristics of Elemental Constituents in Fine Particulate Matter Using a Semi-continuous Measurement System
    Park, Seung Shik
    Ondov, John M.
    JOURNAL OF KOREAN SOCIETY FOR ATMOSPHERIC ENVIRONMENT, 2010, 26 (02) : 190 - 201
  • [30] DEVELOPMENT OF PORE STRUCTURE IN CARBON CLOTH BY HNO3 ACTIVATION
    BARTON, SS
    KORESH, JE
    JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1983, 79 : 1173 - &