Development of Semi-continuous Measurement System for Atmospheric HNO3

被引:1
|
作者
Hwang, Jihyun [1 ]
Kang, Seokwon [1 ]
Kim, Kyunghoon [1 ]
Park, Taehyun [1 ]
Ban, Jihee [1 ]
Song, Jeongin [1 ]
Park, Inseon [1 ]
Shin, Hye-Jung [2 ]
Jung, Hae-Jin [2 ]
Kang, Gong-Unn [3 ]
Bae, Min-Suk [4 ]
Lee, Kwon-Ho [5 ]
Lee, Taehyoung [1 ]
机构
[1] Hankuk Univ Foreign Studies, Dept Environm Sci, Yongin, South Korea
[2] Natl Inst Environm Res, Climate & Air Qual Res Dept, Air Qual Res Div, Incheon, South Korea
[3] Wonkwang Hlth Sci Univ, Dept Med Adm, Iksan, South Korea
[4] Mokpo Natl Univ, Dept Environm Engn, Muan, South Korea
[5] Gangneung Wonju Natl Univ, Dept Atmospher & Environm Sci, Kangnung, South Korea
关键词
Nitric acid; Semi-continuous measurement; Nitric dioxide; Ion chromatography; AMBIENT AIR; PM2.5; AEROSOLS; GASES; SO2; HCL;
D O I
10.5572/KOSAE.2023.39.2.265
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
Nitric acid (HNO3) is formed to ammonium nitrate (NH4NO3) of secondary aerosols by the photochemical reaction. A semi-continuous HNO3 measurement system was developed for the concentration of HNO3 in the atmosphere through ion chromatography after it is sufficiently absorbed by deionized water. In order to correct the Nitrate (NO3-) concentration, an experiment was conducted to simulate the concentration of atmospheric nitrogen dioxide (NO2) and hydrogen peroxide (H2O2) which produce additional NO3-. To evaluate the performance of the instrument, it compared the denuder method, Vocus PTR-TOF (Vocus proton-transfer-reaction time-of-flight mass spectrometer), and semi-continuous HNO3 measurement systems at high concentrations of HNO3 using a standard gas. In addition, an experiment to measure HNO3 in the atmosphere was conducted using both the denuder method and the semi-continuous HNO3 system. The concentration of HNO3 additionally generated by H2O2 and NO2 inside the measurement system was measured lower than the detection limit of the previously performed QC/QA, indicating that it was suitable for measuring HNO3. In the comparison experiment between the different equipment using a standard HNO3 gas, a difference of 4.7% to 8.4% was observed, demonstrating that the results of HNO3 concentration measurements were similar. When measuring HNO3 in the air, the comparison experiment between the semi-continuous HNO3 system and the denuder method showed a high correlation with a coefficient of about 0.98 and a difference of only 0.2%. The semi-continuous HNO3 measuring system was found to be hardly impacted by interference from other materials in the sample and produced results that were similar measured values to using other equipment. Also, it is easy to analyze the concentration and chemical properties of HNO3 during the measurement period because the data is acquired in real-time.
引用
收藏
页码:265 / 277
页数:13
相关论文
共 50 条
  • [1] Semi-continuous gas and inorganic aerosol measurements at a boreal forest site: seasonal and diurnal cycles of NH3, HONO and HNO3
    Makkonen, Ulla
    Virkkula, Aki
    Hellen, Heidi
    Hemmila, Marja
    Sund, Jenni
    Aijala, Mikko
    Ehn, Mikael
    Junninen, Heikki
    Keronen, Petri
    Petaja, Tuukka
    Worsnop, Douglas R.
    Kulmala, Markku
    Hakola, Hannele
    BOREAL ENVIRONMENT RESEARCH, 2014, 19 : 311 - 328
  • [2] RADIATION ABSORPTION IN BANDS OF ATMOSPHERIC HNO3
    MOSKALEN.NI
    IZVESTIYA AKADEMII NAUK SSSR FIZIKA ATMOSFERY I OKEANA, 1972, 8 (02): : 234 - &
  • [3] Passive permeation sampling of atmospheric HNO3
    Osada, Kazuo
    Yamato, Koki
    Song, Qinping
    ATMOSPHERIC ENVIRONMENT, 2021, 267
  • [4] DETERMINATION OF THE CHANNEL OF THE ATMOSPHERIC REACTION OH + HNO3
    POULET, G
    JOURDAIN, JL
    LEBRAS, G
    COMPTES RENDUS DE L ACADEMIE DES SCIENCES SERIE II, 1981, 293 (12): : 899 - 902
  • [5] CONTINUOUS DISCHARGE SYSTEM OF SLUDGE OF STAINLESS STRIP IN HNO3/HF SOLUTION
    MIURA, E
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1986, 72 (05): : S435 - S435
  • [6] SEMI-CONTINUOUS DILATOMETER FOR MEASUREMENT OF EXCESS VOLUMES
    DIAZPENA, M
    NUNEZDELGADO, J
    ANALES DE QUIMICA, 1977, 73 (01): : 24 - 28
  • [7] A Semi-Continuous Analyzer for the Fluorimetric Determination of Atmospheric Formaldehyde
    Sousa, Eliane Teixeira
    de Oliveira, Fabio Santos
    Alves, Arnaldo Cardoso
    de Andrade, Jailson B.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2009, 20 (02) : 259 - 265
  • [8] The transport of atmospheric NOx and HNO3 over Cape Town
    Abiodun, B. J.
    Ojumu, A. M.
    Jenner, S.
    Ojumu, T. V.
    ATMOSPHERIC CHEMISTRY AND PHYSICS, 2014, 14 (02) : 559 - 575
  • [9] COMPARISON OF SUBSTRATES FOR THE COLLECTION OF ATMOSPHERIC HNO3 VAPOR ON FILTERS
    HUEBERT, BJ
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1980, 179 (MAR): : 113 - ANAL
  • [10] Electrochemical study of the graphite—HNO3 system
    V. V. Avdeev
    O. A. Tverezovskaya
    N. E. Sorokina
    I. V. Nikol’skaya
    A. I. Finaenov
    Inorganic Materials, 2000, 36 : 214 - 218