Determination of Scattered Radiation to the Thyroid Gland in Dental Cone Beam Computed Tomography

被引:0
|
作者
Hrangkhawl, Wilson [1 ]
Dkhar, Winniecia [1 ,4 ]
Madhavan, T. S. [2 ]
Sharath, S. [1 ]
Vineetha, R. [3 ]
Chhaparwal, Yogesh [3 ]
机构
[1] Manipal Acad Higher Educ, Manipal Coll Hlth Profess, Dept Med Imaging Technol, Manipal, India
[2] Jaipur Natl Univ, Sch Allied Sci, Dept Med Imaging Technol, Jaipur, India
[3] Manipal Acad Higher Educ, Manipal Coll Dent Sci, Dept Oral & Dent Radiol, Manipal, India
[4] Manipal Acad Higher Educ, Manipal Coll Hlth Profess, Dept Med Imaging Technol, Manipal 576104, India
来源
关键词
Cone Beam Computed Tomography; Maxilla; Mandible; Scattered Radiation Dose; Thyroid Gland;
D O I
10.14407/jrpr.2021.00395
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Background: Cone beam computed tomography (CBCT) is a specialized medical equipment and plays a significant role in the diagnosis of oral and maxillofacial diseases and abnormalities; however, it is attributed to risk of exposure of ionizing radiation. The aim of the study was to es-timate and determine the amount of scattered radiation dose to the thyroid gland in dental CBCT during maxilla and mandible scan.Materials and Methods: The average scattered radiation dose for i-CAT 17-19 Platinum CBCT (Imaging Sciences International) was measured using a Multi-O-Meter (Unfors Instru-ments), placed at the patient's neck on the skin surface of the thyroid cartilage, with an exposure parameter of 120 kVp and 37.07 mAs. The surface entrance dose was noted using the Multi-O -Meter, which was placed at the time of the scan at the level of the thyroid gland on the anterior surface of the neck.Results and Discussion: The surface entrance dose to the thyroid from both jaws scans was 191.491 +/- 78.486 mu Gy for 0.25 mm voxel and 26.9 seconds, and 153.670 +/- 74.041 mu Gy from the mandible scan, whereas from the maxilla scan the surface entrance dose was 5.259 +/- 10.691 mu Gy.Conclusion: The surface entrance doses to the thyroid gland from imaging of both the jaws, and also from imaging of the maxilla and mandible alone were within the threshold limit. The surface entrance dose and effective dose in CBCT were dependent on the exposure parameters (kVp and mAs), scan length, and field of view. To further reduce the radiation dose, care should be taken in selecting an appropriate protocol as well as the provision of providing shield-ing to the thyroid gland.
引用
收藏
页码:15 / 19
页数:5
相关论文
共 50 条
  • [1] Impact of thyroid gland shielding on radiation doses in dental cone beam computed tomography with small and medium fields of view
    Gruening, Melanie
    Koivisto, Juha
    Mah, James
    Bumann, Axel
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2022, 134 (02): : 245 - 253
  • [2] EVALUATION OF THYROID RADIATION DOSE USING CONE BEAM COMPUTED TOMOGRAPHY
    Penteado Setti da Rocha, Anna Silvia
    Aguiar, Guilherme de Mello
    Tulio, Ana Paula
    Ditzel, Alessandra S.
    Filipov, Danielle
    RADIATION PROTECTION DOSIMETRY, 2017, 175 (03) : 368 - 372
  • [3] Dental Cone-Beam Computed Tomography: Are the Eye Lens and Thyroid at Risk?
    Albahiti, Sarah K.
    Jadu, Fatima M.
    Badr, Fatma
    Khalifa, Hanadi
    Khan, Emad
    Khafaji, Mawya
    INTERNATIONAL JOURNAL OF BIOMEDICINE, 2024, 14 (01) : 77 - 82
  • [4] Characterization of Scattered X-Ray Photons in Dental Cone-Beam Computed Tomography
    Yang, Ching-Ching
    PLOS ONE, 2016, 11 (03):
  • [5] Radiation protection in dental imaging: Evaluating the impact of the SABA thyroid shield during panoramic and cone beam computed tomography
    Bawazeer, Omemh
    Almutairi, Hanan
    Almutiri, Khulood
    Fallatah, Alaa
    Alasmary, Mohamed
    Bokhary, Younis
    Abuzaid, Mohamed
    Ajlouni, Abdulwali
    Bawazir, Saeed
    Al-Qahtani, Saeed
    Qutub, Mohammad
    Alotaibi, Emtenan
    Algethami, Merfat
    Alhazmi, Marwan
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2024, 17 (04)
  • [6] Correction for patient table-induced scattered radiation in cone-beam computed tomography (CBCT)
    Sun, Mingshan
    Nagy, Tamas
    Virshup, Gary
    Partain, Larry
    Oelhafen, Markus
    Star-Lack, Josh
    MEDICAL PHYSICS, 2011, 38 (04) : 2058 - 2073
  • [7] Analyzing the Effect of Scattered Photons on Cone Beam Computed Tomography-Based Adaptive Radiation Therapy
    Usui, K.
    Inoue, T.
    Kurokawa, C.
    Sugimoto, S.
    Sasai, K.
    Ogawa, K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E635 - E635
  • [8] Correction of scattered radiation for Cone-beam Computed Tomography at high X-ray energies
    Flisch, Alexander
    Miceli, Alice
    Thierry, Raphael
    Hofmann, Juergen
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 5430 - 5437
  • [9] Radiation Exposure of Abdominal Cone Beam Computed Tomography
    Anna M. Sailer
    Geert Willem H. Schurink
    Joachim E. Wildberger
    Rick de Graaf
    Willem H. van Zwam
    Michiel W. de Haan
    Gerrit J. Kemerink
    Cécile R. L. P. N. Jeukens
    CardioVascular and Interventional Radiology, 2015, 38 : 112 - 120
  • [10] Radiation Exposure of Abdominal Cone Beam Computed Tomography
    Sailer, Anna M.
    Schurink, Geert Willem H.
    Wildberger, Joachim E.
    de Graaf, Rick
    van Zwam, Willem H.
    de Haan, Michiel W.
    Kemerink, Gerrit J.
    Jeukens, Cecile R. L. P. N.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2015, 38 (01) : 112 - 120