The apparent effusivity method for normalized thermal contrast evaluation in infrared thermographic testing

被引:3
|
作者
Moskovchenko, Alexey [1 ]
Svantner, Michal [1 ]
Muzika, Lukas [1 ]
Skala, Jiri [1 ]
Pereira, Celeste M. C. [2 ]
Das, Shumit [3 ]
机构
[1] Univ West Bohemia, Univ 2732-8, Plzen 30100, Czech Republic
[2] Optimal Struct Solut Lda, Rua Moinho Vermelho 50, P-2645449 Cascais, Portugal
[3] European Space Res Technol Ctr ESA ESTEC, Keplerlaan 1, NL-2200 AG Noordwijk, Netherlands
关键词
Infrared thermography; Nondestructive testing; Contrast; CNR; CFRP; Defects quantification; Nondestructive evaluation; Nondestructive inspection; IRNDT; Thermographic testing; Defects contrast; DEFECT CHARACTERIZATION; NDT; TOMOGRAPHY;
D O I
10.1016/j.infrared.2023.104931
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Thermographic nondestructive testing is used for the detection of near-surface discontinuities in materials, where indications of potential defects or discontinuities are detected and evaluated by their thermal contrast. The key requirements for successful thermographic data processing include managing non-uniform heating and identifying nominal areas. Advanced methods often rely on numerical simulation, which can be challenging and timeconsuming. This study suggests a new simple method of thermal contrast calculation for flash-pulse thermography. It is based on the analysis of the inverse apparent effusivity. It includes an automated indication of the sound (defect-free) area and the creation of an artificial reference sequence, which is based on a temperature profile of the sound area and the non-uniform heating map. Derivative analysis of the smoothed contrast data is applied to improve detectability and Contrast/Noise Ratio (CNR). An experimental comparison of the proposed method with other known methods is presented. In the presented example, it allowed detection of 23 defects with an average CNR of 6.13 dB, against the traditional differential absolute contrast method, which detected only 13 defects with an average CNR of 0.53 dB. Thus, high detectability and high CNR values provided by the proposed method are demonstrated.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Infrared thermal imaging as a novel evaluation method for deep vein thrombosis in lower limbs
    Deng, Fangge
    Tang, Qing
    Zheng, Yujiang
    Zeng, Guangqiao
    Zhong, Nanshan
    MEDICAL PHYSICS, 2012, 39 (12) : 7224 - 7231
  • [42] An infrared thermography-based method for the evaluation of the thermal response of tooling for composites manufacturing
    Zobeiry, Navid
    Park, John
    Poursartip, Anoush
    JOURNAL OF COMPOSITE MATERIALS, 2019, 53 (10) : 1277 - 1290
  • [43] INFRARED THERMAL IMAGING AS A NOVEL EVALUATION METHOD FOR DEEP VEIN THROMBOSIS AT LOWER LIMBS
    Deng, F.
    Tang, Q.
    Zheng, Y. J.
    Zeng, G. Q.
    Zhong, N. S.
    RESPIROLOGY, 2012, 17 : 105 - 105
  • [44] Method and Equipment for Infrared and Ultrasonic Thermographic Testing of Large-Sized Complex-Shaped Composite Products (vol 57, pg 619, 2021)
    Chulkov, A. O.
    Nesteruk, D. A.
    Shagdyrov, B. I.
    Vavilov, V. P.
    RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 2021, 57 (09) : 824 - 824
  • [45] Low Contrast Infrared Target Detection Method Based on Residual Thermal Backbone Network and Weighting Loss Function
    Zhao, Chunhui
    Wang, Jinpeng
    Su, Nan
    Yan, Yiming
    Xing, Xiangwei
    REMOTE SENSING, 2022, 14 (01)
  • [46] Efficient algorithm for thermal nondestructive testing and evaluation by considering the heteroscedastic nature of noise sources in infrared thermography
    Kaur, Jasleen
    Babu, Prabhu
    Mulaveesala, Ravibabu
    SURFACE TOPOGRAPHY-METROLOGY AND PROPERTIES, 2024, 12 (04):
  • [47] Analysis of infrared thermal wave nondestructive testing on flat bottom hole sample by the finite element method
    Ding Youfu
    Shen Jingling
    Mang Cunlin
    Jin Wanping
    Feng Lichun
    Tao Ning
    Zhao Shibin
    Li Yanhong
    CONFERENCE DIGEST OF THE 2006 JOINT 31ST INTERNATIONAL CONFERENCE ON INFRARED AND MILLIMETER WAVES AND 14TH INTERNATIONAL CONFERENCE ON TERAHERTZ ELECTRONICS, 2006, : 324 - 324
  • [48] Studies of a new accelerated evaluation method for coating corrosion resistance - thermal cycling testing
    Bierwagen, GP
    He, L
    Li, J
    Ellingson, L
    Tallman, DE
    PROGRESS IN ORGANIC COATINGS, 2000, 39 (01) : 67 - 78
  • [49] Infrared Thermal Imaging for Evaluation of Clubfoot After the Ponseti Casting Method-An Exploratory Study
    Ganesan, Balasankar
    Yip, Joanne
    Luximon, Ameersing
    Gibbons, Paul J.
    Chivers, Alison
    Balasankar, Suchita Kothe
    Tong, Raymond Kai-Yu
    Chai, Rifai
    Al-Jumaily, Adel
    FRONTIERS IN PEDIATRICS, 2021, 9
  • [50] A comprehensive evaluation of the performance of temperature and emissivity separation method with simulated thermal infrared hyperspectral data
    Wang, Ning
    Qian, Yonggang
    Ma, Lingling
    Tang, Lingli
    Li, Chuanrong
    2013 5TH WORKSHOP ON HYPERSPECTRAL IMAGE AND SIGNAL PROCESSING: EVOLUTION IN REMOTE SENSING (WHISPERS), 2013,