The apparent effusivity method for normalized thermal contrast evaluation in infrared thermographic testing

被引:3
|
作者
Moskovchenko, Alexey [1 ]
Svantner, Michal [1 ]
Muzika, Lukas [1 ]
Skala, Jiri [1 ]
Pereira, Celeste M. C. [2 ]
Das, Shumit [3 ]
机构
[1] Univ West Bohemia, Univ 2732-8, Plzen 30100, Czech Republic
[2] Optimal Struct Solut Lda, Rua Moinho Vermelho 50, P-2645449 Cascais, Portugal
[3] European Space Res Technol Ctr ESA ESTEC, Keplerlaan 1, NL-2200 AG Noordwijk, Netherlands
关键词
Infrared thermography; Nondestructive testing; Contrast; CNR; CFRP; Defects quantification; Nondestructive evaluation; Nondestructive inspection; IRNDT; Thermographic testing; Defects contrast; DEFECT CHARACTERIZATION; NDT; TOMOGRAPHY;
D O I
10.1016/j.infrared.2023.104931
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Thermographic nondestructive testing is used for the detection of near-surface discontinuities in materials, where indications of potential defects or discontinuities are detected and evaluated by their thermal contrast. The key requirements for successful thermographic data processing include managing non-uniform heating and identifying nominal areas. Advanced methods often rely on numerical simulation, which can be challenging and timeconsuming. This study suggests a new simple method of thermal contrast calculation for flash-pulse thermography. It is based on the analysis of the inverse apparent effusivity. It includes an automated indication of the sound (defect-free) area and the creation of an artificial reference sequence, which is based on a temperature profile of the sound area and the non-uniform heating map. Derivative analysis of the smoothed contrast data is applied to improve detectability and Contrast/Noise Ratio (CNR). An experimental comparison of the proposed method with other known methods is presented. In the presented example, it allowed detection of 23 defects with an average CNR of 6.13 dB, against the traditional differential absolute contrast method, which detected only 13 defects with an average CNR of 0.53 dB. Thus, high detectability and high CNR values provided by the proposed method are demonstrated.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Method of object MRTD-testing for thermal infrared imager
    Xu, Liwei
    Li, Qiang
    Lu, Yingming
    OPTICAL DESIGN AND TESTING VIII, 2018, 10815
  • [22] Method and Equipment for Infrared and Ultrasonic Thermographic Testing of Large-Sized Complex-Shaped Composite Products
    A. O. Chulkov
    D. A. Nesteruk
    B. I. Shagdyrov
    V. P. Vavilov
    Russian Journal of Nondestructive Testing, 2021, 57 : 619 - 626
  • [23] Method and Equipment for Infrared and Ultrasonic Thermographic Testing of Large-Sized Complex-Shaped Composite Products
    Chulkov, A. O.
    Nesteruk, D. A.
    Shagdyrov, B., I
    Vavilov, V. P.
    RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 2021, 57 (07) : 619 - 626
  • [24] Thermal diffusivity measurement using thermographic method and performance evaluation by impedance spectroscopy for thermoelectric module
    Otsuka, Mioko
    Terakado, Hiroki
    Homma, Ryoei
    Hasegawa, Yasuhiro
    Islam, Md. Zahidul
    Bastian, Georg
    Stuck, Alexander
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2016, 55 (12)
  • [25] Erratum to: Method and Equipment for Infrared and Ultrasonic Thermographic Testing of Large-Sized Complex-Shaped Composite Products
    A. O. Chulkov
    D. A. Nesteruk
    B. I. Shagdyrov
    V. P. Vavilov
    Russian Journal of Nondestructive Testing, 2021, 57 : 824 - 824
  • [26] EVALUATION OF THE INFRARED TEST METHOD FOR THE OLYMPUS THERMAL BALANCE TESTS
    DONATO, M
    GREEN, J
    STPIERRE, D
    REEVES, M
    JOURNAL OF ENVIRONMENTAL SCIENCES, 1987, 30 (03): : 45 - 49
  • [27] Thermal infrared image coloring method and evaluation method based on edge consistency
    Cai, Jiaming
    Tang, Xin
    Hu, Yao
    Zhang, Shaohui
    Hao, Qun
    INFRARED PHYSICS & TECHNOLOGY, 2023, 135
  • [28] Thermographic method for evaluation of thermal influence of Nd:YAG laser on a tooth root during sterilization process
    Madura, H
    Dabrowski, M
    Dulski, R
    Zmuda, S
    Zaborowski, P
    INFRARED PHYSICS & TECHNOLOGY, 2004, 46 (1-2) : 167 - 171
  • [29] Innovative Testing Method for the Evaluation of Thermal Shock and Mechanical Wear
    Harksen, S.
    Bleck, W.
    MATERIALS AND MANUFACTURING PROCESSES, 2009, 24 (7-8) : 763 - 765
  • [30] PRELIMINARY EVALUATION OF LINEAR SPECTRAL EMISSIVITY CONSTRAINT TEMPERATURE AND EMISSIVITY SEPARATION METHOD FOR CONTRAST SAMPLES FROM HYPERSPECTRAL THERMAL INFRARED DATA
    Qian, Yong-Gang
    Wang, Ning
    Gao, Caixia
    Jia, Yuan-Yuan
    Ma, Lingling
    Wu, Hua
    Li, Zhao-Liang
    Tang, Lingli
    2013 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2013, : 465 - 468