The apparent effusivity method for normalized thermal contrast evaluation in infrared thermographic testing

被引:3
|
作者
Moskovchenko, Alexey [1 ]
Svantner, Michal [1 ]
Muzika, Lukas [1 ]
Skala, Jiri [1 ]
Pereira, Celeste M. C. [2 ]
Das, Shumit [3 ]
机构
[1] Univ West Bohemia, Univ 2732-8, Plzen 30100, Czech Republic
[2] Optimal Struct Solut Lda, Rua Moinho Vermelho 50, P-2645449 Cascais, Portugal
[3] European Space Res Technol Ctr ESA ESTEC, Keplerlaan 1, NL-2200 AG Noordwijk, Netherlands
关键词
Infrared thermography; Nondestructive testing; Contrast; CNR; CFRP; Defects quantification; Nondestructive evaluation; Nondestructive inspection; IRNDT; Thermographic testing; Defects contrast; DEFECT CHARACTERIZATION; NDT; TOMOGRAPHY;
D O I
10.1016/j.infrared.2023.104931
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Thermographic nondestructive testing is used for the detection of near-surface discontinuities in materials, where indications of potential defects or discontinuities are detected and evaluated by their thermal contrast. The key requirements for successful thermographic data processing include managing non-uniform heating and identifying nominal areas. Advanced methods often rely on numerical simulation, which can be challenging and timeconsuming. This study suggests a new simple method of thermal contrast calculation for flash-pulse thermography. It is based on the analysis of the inverse apparent effusivity. It includes an automated indication of the sound (defect-free) area and the creation of an artificial reference sequence, which is based on a temperature profile of the sound area and the non-uniform heating map. Derivative analysis of the smoothed contrast data is applied to improve detectability and Contrast/Noise Ratio (CNR). An experimental comparison of the proposed method with other known methods is presented. In the presented example, it allowed detection of 23 defects with an average CNR of 6.13 dB, against the traditional differential absolute contrast method, which detected only 13 defects with an average CNR of 0.53 dB. Thus, high detectability and high CNR values provided by the proposed method are demonstrated.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Discrimination Between Over-Thickness and Delamination of Thermal Barrier Coatings by Apparent Thermal Effusivity Thermographic Technique
    F. Cernuschi
    S. Marinetti
    Journal of Thermal Spray Technology, 2010, 19 : 958 - 963
  • [2] Discrimination Between Over-Thickness and Delamination of Thermal Barrier Coatings by Apparent Thermal Effusivity Thermographic Technique
    Cernuschi, F.
    Marinetti, S.
    JOURNAL OF THERMAL SPRAY TECHNOLOGY, 2010, 19 (05) : 958 - 963
  • [3] Active IR Thermography Evaluation of Coating Thickness by Determining Apparent Thermal Effusivity
    Moskovchenko, Alexey
    Vavilov, Vladimir
    Svantner, Michal
    Muzika, Lukas
    Houdkova, Sarka
    MATERIALS, 2020, 13 (18)
  • [4] Quantitative infrared thermographic nondestructive testing of thermal barrier coatings
    Marinetti, S
    Vavilov, V
    Bison, PG
    Grinzato, E
    Cernuschi, F
    MATERIALS EVALUATION, 2003, 61 (06) : 773 - 780
  • [5] Metrological Aspects of Auto-normalized Front Photopyroelectric Method to Measure Thermal Effusivity in Liquids
    G. Gutiérrez-Juárez
    R. Ivanov
    J. P. Pichardo-Molina
    M. Vargas-Luna
    J. J. Alvarado-Gil
    A. Camacho
    International Journal of Thermophysics, 2008, 29 : 2102 - 2115
  • [6] A new thermal contrast for non-destructive thermographic testing of materials
    Benitez, Heinan D.
    Ibarra-Castanedo, Clemente
    Bendada, Abdelhakim
    Maldague, Xavier
    Loaiza, Humberto
    Caicedo, Eduardo
    INGENIERIA Y COMPETITIVIDAD, 2007, 9 (01): : 31 - 44
  • [7] Metrological Aspects of Auto-normalized Front Photopyroelectric Method to Measure Thermal Effusivity in Liquids
    Gutierrez-Juarez, G.
    Ivanov, R.
    Pichardo-Molina, J. P.
    Vargas-Luna, M.
    Alvarado-Gil, J. J.
    Camacho, A.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2008, 29 (06) : 2102 - 2115
  • [8] A Method to Measure and Estimate Normalized Contrast in Infrared Flash Thermography
    Koshti, Ajay M.
    NONDESTRUCTIVE CHARACTERIZATION AND MONITORING OF ADVANCED MATERIALS, AEROSPACE, AND CIVIL INFRASTRUCTURE 2016, 2016, 9804
  • [9] Evaluation of the thermal effusivity of intermetallic compounds using a modulated thermoreflectance method
    Nakamura, Fumiya
    Murakami, Taichi
    Miyake, Shugo
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2022, 61 (SD)
  • [10] Evaluation of the thermal parameters of textile materials using the thermographic method
    Michalak, Marina
    Felczak, Mariusz
    Wiecek, Boguslaw
    Fibres and Textiles in Eastern Europe, 2009, 74 (03): : 84 - 89