Upgrade of the relative calibration methods and Bayesian inference processing for electron cyclotron emission radiometry

被引:0
|
作者
Yu, Xin [1 ]
Shi, Zhongbing [1 ]
Yang, Zengchen [1 ]
Jiang, Min [1 ]
Chen, Wei [1 ]
Wang, Tianbo [1 ]
Pan, Wenan [1 ]
机构
[1] Southwestern Inst Phys, Chengdu 610041, Peoples R China
基金
中国国家自然科学基金;
关键词
MICHELSON INTERFEROMETER;
D O I
10.1051/epjconf/202327703009
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
An upgraded local oscillator (LO) hopping calibration method based on a blackbody hot source and a perturbation analysis of the magnetic field difference method are introduced in this work. The blackbody hot source is used to evaluate the difference in the relative coefficients between the two LO hopping frequencies in the same channels. Then the coefficients are obtained by multiplying the LO hopping frequencies coefficients by LO hopping calibration coefficients. In this way, it is more flexible and stable than the in-situ calibration. The magnetic field difference method provides another calibration method to obtain the relative calibration coefficients of the electron cyclotron emission radiometers (ECE). In general, the magnetic field difference method needs two similar shots but with a difference of 2.1% (for HL-2M) in the magnetic field. Meanwhile, there are some errors because of the deviation of detection positions in the same channels between the two shots. For evaluating the calibration errors, the impact of the displacement, T-e perturbation of the core region, and magnetic field difference has been discussed. The result shows that a larger magnetic field difference can improve the accuracy of the calibration. In the end, Bayesian inference has been utilized to evaluate the calibration coefficients and get the most probable calibration coefficients along with its the confidence interval.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Calibration of a Scanning Electron Microscope: 2. Methods of Signal Processing
    Yu. A. Novikov
    Journal of Surface Investigation: X-ray, Synchrotron and Neutron Techniques, 2021, 15 : 987 - 998
  • [42] CALIBRATION METHODS FOR QUANTITATIVE IMAGE-PROCESSING IN ELECTRON-MICROSCOPY
    LAMVIK, MK
    DAVILLA, S
    JOURNAL OF ELECTRON MICROSCOPY TECHNIQUE, 1989, 11 (02): : 97 - 101
  • [43] A Bayesian calibration model for combining different pre-processing methods in Affymetrix chips
    Marta Blangiardo
    Sylvia Richardson
    BMC Bioinformatics, 9
  • [44] A Bayesian calibration model for combining different pre-processing methods in Affymetrix chips
    Blangiardo, Marta
    Richardson, Sylvia
    BMC BIOINFORMATICS, 2008, 9 (1)
  • [45] Investigating the occurrence and predictability of pitch angle scattering events at ADITYA-Upgrade tokamak with the electron cyclotron emission radiometer
    Varsha SIJU
    Santosh PPANDYA
    SKPATHAK
    Ansh PATEL
    Umesh NAGORA
    Shishir PUROHIT
    Sameer JHA
    MKGUPTA
    KTAHILIANI
    RKUMAR
    RLTANNA
    JGHOSH
    Plasma Science and Technology, 2024, 26 (11) : 50 - 62
  • [46] Investigating the occurrence and predictability of pitch angle scattering events at ADITYA-Upgrade tokamak with the electron cyclotron emission radiometer
    Siju, Varsha
    Pandya, Santosh P.
    Pathak, S. K.
    Patel, Ansh
    Nagora, Umesh
    Purohit, Shishir
    Jha, Sameer
    Gupta, M. K.
    Tahiliani, K.
    Kumar, R.
    Tanna, R. L.
    Ghosh, J.
    PLASMA SCIENCE & TECHNOLOGY, 2024, 26 (11)
  • [47] Temperature gradient scale length measurement: A high accuracy application of electron cyclotron emission without calibration
    Houshmandyar, S.
    Yang, Z. J.
    Phillips, P. E.
    Rowan, W. L.
    Hubbard, A. E.
    Rice, J. E.
    Hughes, J. W.
    Wolfe, S. M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11):
  • [48] HETERODYNE MEASUREMENTS OF ELECTRON-CYCLOTRON EMISSION FROM ALCATOR-A AND ABSOLUTE SUBMILLIMETER RECEIVER CALIBRATION
    WOSKOBOINIKOW, P
    PRADDAUDE, HC
    FALCONER, IS
    MULLIGAN, WJ
    JOURNAL OF APPLIED PHYSICS, 1981, 52 (12) : 7099 - 7106
  • [49] Improved cross-calibration of Thomson scattering and electron cyclotron emission with ECH on DIII-D
    Brookman, M. W.
    Austin, M. E.
    McLean, A. G.
    Carlstrom, T. N.
    Hyatt, A. W.
    Lohr, J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11):
  • [50] Electron cyclotron emission calibration with Thomson scattering using a wide scan of toroidal magnetic field of KSTAR
    Lee, K. D.
    Lee, J. H.
    Nam, Y. U.
    Pyo, S.