Upgrade of the relative calibration methods and Bayesian inference processing for electron cyclotron emission radiometry

被引:0
|
作者
Yu, Xin [1 ]
Shi, Zhongbing [1 ]
Yang, Zengchen [1 ]
Jiang, Min [1 ]
Chen, Wei [1 ]
Wang, Tianbo [1 ]
Pan, Wenan [1 ]
机构
[1] Southwestern Inst Phys, Chengdu 610041, Peoples R China
基金
中国国家自然科学基金;
关键词
MICHELSON INTERFEROMETER;
D O I
10.1051/epjconf/202327703009
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
An upgraded local oscillator (LO) hopping calibration method based on a blackbody hot source and a perturbation analysis of the magnetic field difference method are introduced in this work. The blackbody hot source is used to evaluate the difference in the relative coefficients between the two LO hopping frequencies in the same channels. Then the coefficients are obtained by multiplying the LO hopping frequencies coefficients by LO hopping calibration coefficients. In this way, it is more flexible and stable than the in-situ calibration. The magnetic field difference method provides another calibration method to obtain the relative calibration coefficients of the electron cyclotron emission radiometers (ECE). In general, the magnetic field difference method needs two similar shots but with a difference of 2.1% (for HL-2M) in the magnetic field. Meanwhile, there are some errors because of the deviation of detection positions in the same channels between the two shots. For evaluating the calibration errors, the impact of the displacement, T-e perturbation of the core region, and magnetic field difference has been discussed. The result shows that a larger magnetic field difference can improve the accuracy of the calibration. In the end, Bayesian inference has been utilized to evaluate the calibration coefficients and get the most probable calibration coefficients along with its the confidence interval.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Hybrid electron cyclotron emission imaging array system for Texas experimental tokamak upgrade
    Hsia, RP
    Deng, BH
    Geck, WR
    Liang, C
    Domier, CW
    Luhmann, NC
    Brower, DL
    Cima, G
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (01): : 488 - 491
  • [22] Calibration of Thomson scattering systems using electron cyclotron emission cutoff data
    Zhurovich, K.
    Mossessian, D. A.
    Hughes, J. W.
    Hubbard, A. E.
    Irby, J. H.
    Marmar, E. S.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (05):
  • [23] Absolute calibration method of electron cyclotron emission imaging system on EAST tokamak
    Pei Bo-Yang
    Zhuang Ge
    Xie Jin-Lin
    Zhou Yi-Nan
    ACTA PHYSICA SINICA, 2024, 73 (13)
  • [24] WHISTLER MODE ELECTRON-CYCLOTRON EMISSION FROM ENERGETIC ELECTRONS IN TMX-UPGRADE
    LASNIER, CJ
    ELLIS, RF
    TSAKIRIS, GD
    JAMES, RA
    CASPER, TA
    PLASMA PHYSICS AND CONTROLLED FUSION, 1988, 30 (05) : 491 - 513
  • [25] High spatial resolution upgrade of the electron cyclotron emission radiometer for the DIII-D tokamak
    Truong, D. D.
    Austin, M. E.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (11):
  • [26] Determination of rational surface position and magnetic island width from electron cyclotron emission (ECE) radiometry in TCABR
    Fonseca, AMM
    Tsypin, VS
    Galvao, RMO
    Nascimento, IC
    Kuznetsov, YK
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2005, 33 (06) : 2046 - 2050
  • [27] Calibration of an electron cyclotron emission diagnostic system and electron temperature measurements on HT-7 tokamak
    Sajjad, S.
    Gao, X.
    Ling, B.
    Ti, A.
    Du, Q.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2008, 19 (07)
  • [28] Electron cyclotron emission measurements on JET: Michelson interferometer, new absolute calibration, and determination of electron temperature
    Schmuck, S.
    Fessey, J.
    Gerbaud, T.
    Alper, B.
    Beurskens, M. N. A.
    de la Luna, E.
    Sirinelli, A.
    Zerbini, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (12):
  • [29] Calibration of a 32 channel electron cyclotron emission radiometer on the HL-2A tokamak
    Shi, Z. B.
    Jiang, M.
    Huang, X. L.
    Zhong, W. L.
    Chen, W.
    Che, Y. L.
    Liu, Z. T.
    Ding, X. T.
    Yang, Q. W.
    Duan, X. R.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (02):
  • [30] Development of electronics and data acquisition system for independent calibration of electron cyclotron emission radiometer
    Kumari, Praveena
    Raulji, Vismaysinh
    Mandaliya, Hitesh
    Patel, Jignesh
    Siju, Varsha
    Pathak, S. K.
    Rajpal, Rachana
    Jha, R.
    FUSION ENGINEERING AND DESIGN, 2016, 112 : 924 - 927