An Intra-Individual Comparison of Low-keV Photon-Counting CT versus Energy-Integrating-Detector CT Angiography of the Aorta

被引:1
|
作者
Hennes, Jan-Lucca [1 ]
Huflage, Henner [1 ]
Grunz, Jan-Peter [1 ]
Hartung, Viktor [1 ]
Augustin, Anne Marie [1 ]
Patzer, Theresa Sophie [1 ]
Pannenbecker, Pauline [1 ]
Petritsch, Bernhard [1 ]
Bley, Thorsten Alexander [1 ]
Gruschwitz, Philipp [1 ]
机构
[1] Univ Hosp Wurzburg, Dept Diagnost & Intervent Radiol, D-97080 Wurzburg, Germany
关键词
CT angiography; aorta; photon-counting-detector CT; radiation dose reduction; spectral imaging; COMPUTED-TOMOGRAPHY; NOISE; PITCH; REDUCTION; DISEASE; PHANTOM; MDCT;
D O I
10.3390/diagnostics13243645
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This retrospective study aims to provide an intra-individual comparison of aortic CT angiographies (CTAs) using first-generation photon-counting-detector CT (PCD-CT) and third-generation energy-integrating-detector CT (EID-CT). High-pitch CTAs were performed with both scanners and equal contrast-agent protocols. EID-CT employed automatic tube voltage selection (90/100 kVp) with reference tube current of 434/350 mAs, whereas multi-energy PCD-CT scans were generated with fixed tube voltage (120 kVp), image quality level of 64, and reconstructed as 55 keV monoenergetic images. For image quality assessment, contrast-to-noise ratios (CNRs) were calculated, and subjective evaluation (overall quality, luminal contrast, vessel sharpness, blooming, and beam hardening) was performed independently by three radiologists. Fifty-seven patients (12 women, 45 men) were included with a median interval between examinations of 12.7 months (interquartile range 11.1 months). Using manufacturer-recommended scan protocols resulted in a substantially lower radiation dose in PCD-CT (size-specific dose estimate: 4.88 +/- 0.48 versus 6.28 +/- 0.50 mGy, p < 0.001), while CNR was approximately 50% higher (41.11 +/- 8.68 versus 27.05 +/- 6.73, p < 0.001). Overall image quality and luminal contrast were deemed superior in PCD-CT (p < 0.001). Notably, EID-CT allowed for comparable vessel sharpness (p = 0.439) and less pronounced blooming and beam hardening (p < 0.001). Inter-rater agreement was good to excellent (0.58-0.87). Concluding, aortic PCD-CTAs facilitate increased image quality with significantly lower radiation dose compared to EID-CTAs.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Submillisievert Abdominal Photon-Counting CT versus Energy-integrating Detector CT for Urinary Calculi Detection: Impact on Diagnostic Confidence
    Huflage, Henner
    Kunz, Andreas Steven
    Patzer, Theresa Sophie
    Pichlmeier, Svenja
    Westhofen, Thilo
    Gruschwitz, Philipp
    Heidenreich, Julius Frederik
    Lennartz, Simon
    Bley, Thorsten Alexander
    Grunz, Jan-Peter
    RADIOLOGY, 2024, 312 (01)
  • [32] Metal artifacts and artifact reduction of neurovascular coils in photon-counting detector CT versus energy-integrating detector CT — in vitro comparison of a standard brain imaging protocol
    Niclas Schmitt
    Lena Wucherpfennig
    Lukas T. Rotkopf
    Stefan Sawall
    Hans-Ulrich Kauczor
    Martin Bendszus
    Markus A. Möhlenbruch
    Heinz-Peter Schlemmer
    Dominik F. Vollherbst
    European Radiology, 2023, 33 : 803 - 811
  • [33] Metal artifacts and artifact reduction of neurovascular coils in photon-counting detector CT versus energy-integrating detector CT - in vitro comparison of a standard brain imaging protocol
    Schmitt, Niclas
    Wucherpfennig, Lena
    Rotkopf, Lukas T.
    Sawall, Stefan
    Kauczor, Hans-Ulrich
    Bendszus, Martin
    Moehlenbruch, Markus A.
    Schlemmer, Heinz-Peter
    Vollherbst, Dominik F.
    EUROPEAN RADIOLOGY, 2023, 33 (02) : 803 - 811
  • [34] Photon-Counting Detector CT Virtual Monoengergetic Images for Cochlear Implant Visualization-A Head to Head Comparison to Energy-Integrating Detector CT
    Waldeck, Stephan
    Overhoff, Daniel
    Alizadeh, Leona
    Becker, Benjamin, V
    Port, Matthias
    Froelich, Matthias F.
    Brockmann, Marc A.
    Schumann, Sven
    Vogl, Thomas J.
    Schoenberg, Stefan O.
    Schmidt, Sandra
    TOMOGRAPHY, 2022, 8 (04) : 1642 - 1648
  • [35] A Silicon-Strip Detector for Photon-Counting Spectral CT: Energy Resolution From 40 keV to 120 keV
    Liu, Xuejin
    Bornefalk, Hans
    Chen, Han
    Danielsson, Mats
    Karlsson, Staffan
    Persson, Mats
    Xu, Cheng
    Huber, Ben
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (03) : 1099 - 1105
  • [36] Photon- Counting Detector CT Versus Energy- Integrating Detector CT of the Lumbar Spine: Comparison of Radiation Dose and Image Quality
    Marth, Adrian A.
    Marcus, Roy P.
    Feuerriegel, Georg C.
    Nanz, Daniel
    Sutter, Reto
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2024, 222 (01)
  • [37] Photon-counting detector CT improves quality of arterial phase abdominal scans: A head-to-head comparison with energy-integrating CT
    Graafen, D.
    Muller, L.
    Halfmann, M.
    Duber, C.
    Hahn, F.
    Yang, Y.
    Emrich, T.
    Kloeckner, R.
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 156
  • [38] Combination of current-integrating/photon-counting detector modules for spectral CT
    Chu, Jiyang
    Cong, Wenxiang
    Li, Liang
    Wang, Ge
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (19): : 7009 - 7024
  • [39] Comparison of low-energy virtual monoenergetic images between photon-counting CT and energy-integrating detectors CT: A phantom study
    Greffier, Joel
    Faby, Sebastian
    Pastor, Maxime
    Frandon, Julien
    Erath, Julien
    Beregi, Jean Paul
    Dabli, Djamel
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2024, 105 (09) : 311 - 318
  • [40] Low-dose high-resolution chest CT in adults with cystic fibrosis: intraindividual comparison between photon-counting and energy-integrating detector CT
    Frings, Marko
    Welsner, Matthias
    Mousa, Christin
    Zensen, Sebastian
    Salhoefer, Luca
    Meetschen, Mathias
    Beck, Nikolas
    Bos, Denise
    Westhoelter, Dirk
    Wienker, Johannes
    Taube, Christian
    Umutlu, Lale
    Schaarschmidt, Benedikt M.
    Forsting, Michael
    Haubold, Johannes
    Sutharsan, Sivagurunathan
    Opitz, Marcel
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2024, 8 (01)