Photon-counting detector CT improves quality of arterial phase abdominal scans: A head-to-head comparison with energy-integrating CT

被引:21
|
作者
Graafen, D. [1 ]
Muller, L. [1 ]
Halfmann, M. [1 ,2 ]
Duber, C. [1 ]
Hahn, F. [1 ]
Yang, Y. [1 ]
Emrich, T. [1 ,2 ]
Kloeckner, R. [1 ,3 ]
机构
[1] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Diagnost & Intervent Radiol, Langenbeckstr 1, D-55131 Mainz, Germany
[2] German Ctr Cardiovasc Res DZHK, Partner Site Rhine Main, Mainz, Germany
[3] Univ Hosp Schleswig Holstein, Inst Intervent Radiol, Campus Lubeck, Lubeck, Germany
关键词
Abdomen; Computed tomography; Photon -counting detector; Virtual monoenergetic imaging; LOW TUBE VOLTAGE; COMPUTED-TOMOGRAPHY; DOSE REDUCTION; CONTRAST AGENT; LIVER-LESIONS; NOISE RATIO; SETTINGS;
D O I
10.1016/j.ejrad.2022.110514
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Photon-counting detector (PCD)-CT is expected to have a substantial impact on oncologic abdominal imaging. We compared subjective and objective image quality between PCD-CT and conventional energy -integrating detector (EID-)CT arterial phase abdominal scans.Methods: This study included 84 patients undergoing both types of abdominal CT. EID-CT scans were acquired with a tube voltage of 100 kVp. With PCD-CT, acquired with 120-kVp, we reconstructed polychromatic T3D images and virtual monoenergetic images (VMIs) in 10-keV intervals from 40 to 90 keV. Quantitative image analysis included noise and contrast-to-noise ratio (CNR) of hepatic vessels, kidney cortex, and hypervascular liver lesions to liver parenchyma. Three raters used a 5-point Likert scale for qualitative image analysis of image noise and contrast, lesion conspicuity, and overall image quality. Radiation dose exposure (CT dose index) was compared between the two CT types.Results: Mean CT dose index and effective dose were respectively 18 % and 26 % lower with PCD-CT versus EID-CT. Compared with EID-CT, CNRs of kidney cortex and vessel to liver parenchyma were significantly higher in PCD-CT VMIs at energies <= 60 keV and in polychromatic T3D images (p < 0.004). Overall image quality of PCD-CT VMIs at 50 and 60 keV was rated as significantly better (p < 0.01) than the EID-CT images (inter-reader agreement alpha = 0.80). Lesion conspicuity was significantly better in low-keV VMIs (p < 0.03) and worse in > 70-keV VMIs.Conclusions: With low-keV VMI, PCD-CT yields significantly improved objective and subjective quality of arterial phase oncological imaging compared with EID-CT. This advantage may translate into higher diagnostic confi-dence and lower radiation dose protocols.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Photon-Counting Detector CT Virtual Monoengergetic Images for Cochlear Implant Visualization-A Head to Head Comparison to Energy-Integrating Detector CT
    Waldeck, Stephan
    Overhoff, Daniel
    Alizadeh, Leona
    Becker, Benjamin, V
    Port, Matthias
    Froelich, Matthias F.
    Brockmann, Marc A.
    Schumann, Sven
    Vogl, Thomas J.
    Schoenberg, Stefan O.
    Schmidt, Sandra
    TOMOGRAPHY, 2022, 8 (04) : 1642 - 1648
  • [2] Contrast-Enhanced Abdominal CT with Clinical Photon-Counting Detector CT: Assessment of Image Quality and Comparison with Energy-Integrating Detector CT
    Higashigaito, Kai
    Euler, Andre
    Eberhard, Matthias
    Flohr, Thomas G.
    Schmidt, Bernhard
    Alkadhi, Hatem
    ACADEMIC RADIOLOGY, 2022, 29 (05) : 689 - 697
  • [3] Stent appearance in a novel silicon-based photon-counting CT prototype: ex vivo phantom study in head-to-head comparison with conventional energy-integrating CT
    Emma Verelst
    Nico Buls
    Johan De Mey
    Koenraad Hans Nieboer
    Frans Vandenbergh
    Dominic Crotty
    Paul Deak
    Albert Sundvall
    Staffan Holmin
    Aron De Smet
    Steven Provyn
    Gert Van Gompel
    European Radiology Experimental, 7
  • [4] Stent appearance in a novel silicon-based photon-counting CT prototype: ex vivo phantom study in head-to-head comparison with conventional energy-integrating CT
    Verelst, Emma
    Buls, Nico
    De Mey, Johan
    Nieboer, Koenraad Hans
    Vandenbergh, Frans
    Crotty, Dominic
    Deak, Paul
    Sundvall, Albert
    Holmin, Staffan
    De Smet, Aron
    Provyn, Steven
    Van Gompel, Gert
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2023, 7 (01)
  • [5] Comparison of Image Quality and Radiation Dose in Pediatric Temporal Bone CT Using Photon-Counting Detector CT and Energy-Integrating Detector CT
    Lee, Jeong Sub
    Kim, John
    Bapuraj, Jayapalli R.
    Srinivasan, Ashok
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2024, 45 (09) : 1322 - 1326
  • [6] Comparison Study of Myocardial Radiomics Feature Properties on Energy-Integrating and Photon-Counting Detector CT
    Ayx, Isabelle
    Tharmaseelan, Hishan
    Hertel, Alexander
    Noerenberg, Dominik
    Overhoff, Daniel
    Rotkopf, Lukas T.
    Riffel, Philipp
    Schoenberg, Stefan O.
    Froelich, Matthias F.
    DIAGNOSTICS, 2022, 12 (05)
  • [7] Low-dose CT of the abdomen: Initial experience on a novel photon-counting detector CT and comparison with energy-integrating detector CT
    Decker, Josua A.
    Bette, Stefanie
    Lubina, Nora
    Rippel, Katharina
    Braun, Franziska
    Risch, Franka
    Wollny, Claudia
    Scheurig-Muenkler, Christian
    Kroencke, Thomas J.
    Schwarz, Florian
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 148
  • [8] Infrapopliteal Segments on Lower Extremity CTA: Prospective Intraindividual Comparison of Energy-Integrating Detector CT and Photon-Counting Detector CT
    Yalon, Mariana
    Inoue, Akitoshi
    Thorne, Jamison E.
    Lee, Yong S.
    Johnson, Matthew P.
    Esquivel, Andrea
    Leng, Shuai
    McCollough, Cynthia H.
    Fletcher, Joel G.
    Rajiah, Prabhakar Shantha
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2024, 222 (03)
  • [9] Comparison of Photon-counting Detector and Energy-integrating Detector CT for Visual Estimation of Coronary Percent Luminal Stenosis
    Mccollough, Cynthia H.
    Rajiah, Prabhakar
    Bois, John P.
    Winfree, Tim N.
    Carter, Rickey E.
    Rajendran, Kishore
    Williamson, Eric E.
    Thorne, Jamison E.
    Leng, Shuai
    RADIOLOGY, 2023, 309 (03)
  • [10] Image quality of photon counting and energy integrating chest CT-Prospective head-to-head comparison on same patients
    Schwartz, Fides R.
    Ria, Francesco
    McCabe, Cindy
    Zarei, Mojtaba
    Rajagopal, Jayasai
    Molvin, Lior
    Marin, Daniele
    O'Sullivan-Murphy, Bryan
    Kalisz, Kevin R.
    Tailor, Tina D.
    Washington, Lacey
    Henry, Travis
    Samei, Ehsan
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 166