Photon-counting detector CT improves quality of arterial phase abdominal scans: A head-to-head comparison with energy-integrating CT

被引:21
|
作者
Graafen, D. [1 ]
Muller, L. [1 ]
Halfmann, M. [1 ,2 ]
Duber, C. [1 ]
Hahn, F. [1 ]
Yang, Y. [1 ]
Emrich, T. [1 ,2 ]
Kloeckner, R. [1 ,3 ]
机构
[1] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Diagnost & Intervent Radiol, Langenbeckstr 1, D-55131 Mainz, Germany
[2] German Ctr Cardiovasc Res DZHK, Partner Site Rhine Main, Mainz, Germany
[3] Univ Hosp Schleswig Holstein, Inst Intervent Radiol, Campus Lubeck, Lubeck, Germany
关键词
Abdomen; Computed tomography; Photon -counting detector; Virtual monoenergetic imaging; LOW TUBE VOLTAGE; COMPUTED-TOMOGRAPHY; DOSE REDUCTION; CONTRAST AGENT; LIVER-LESIONS; NOISE RATIO; SETTINGS;
D O I
10.1016/j.ejrad.2022.110514
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Photon-counting detector (PCD)-CT is expected to have a substantial impact on oncologic abdominal imaging. We compared subjective and objective image quality between PCD-CT and conventional energy -integrating detector (EID-)CT arterial phase abdominal scans.Methods: This study included 84 patients undergoing both types of abdominal CT. EID-CT scans were acquired with a tube voltage of 100 kVp. With PCD-CT, acquired with 120-kVp, we reconstructed polychromatic T3D images and virtual monoenergetic images (VMIs) in 10-keV intervals from 40 to 90 keV. Quantitative image analysis included noise and contrast-to-noise ratio (CNR) of hepatic vessels, kidney cortex, and hypervascular liver lesions to liver parenchyma. Three raters used a 5-point Likert scale for qualitative image analysis of image noise and contrast, lesion conspicuity, and overall image quality. Radiation dose exposure (CT dose index) was compared between the two CT types.Results: Mean CT dose index and effective dose were respectively 18 % and 26 % lower with PCD-CT versus EID-CT. Compared with EID-CT, CNRs of kidney cortex and vessel to liver parenchyma were significantly higher in PCD-CT VMIs at energies <= 60 keV and in polychromatic T3D images (p < 0.004). Overall image quality of PCD-CT VMIs at 50 and 60 keV was rated as significantly better (p < 0.01) than the EID-CT images (inter-reader agreement alpha = 0.80). Lesion conspicuity was significantly better in low-keV VMIs (p < 0.03) and worse in > 70-keV VMIs.Conclusions: With low-keV VMI, PCD-CT yields significantly improved objective and subjective quality of arterial phase oncological imaging compared with EID-CT. This advantage may translate into higher diagnostic confi-dence and lower radiation dose protocols.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Investigation of abdominal artery delineation by photon-counting detector CT
    Ota, Takashi
    Onishi, Hiromitsu
    Itoh, Toshihide
    Fukui, Hideyuki
    Tsuboyama, Takahiro
    Nakamoto, Atsushi
    Enchi, Yukihiro
    Tatsumi, Mitsuaki
    Tomiyama, Noriyuki
    RADIOLOGIA MEDICA, 2024, : 1265 - 1274
  • [42] Virtual Noncontrast Abdominal Imaging with Photon-counting Detector CT
    Mergen, Victor
    Racine, Damien
    Jungblut, Lisa
    Sartoretti, Thomas
    Bickel, Steven
    Monnin, Pascal
    Higashigaito, Kai
    Martini, Katharina
    Alkadhi, Hatem
    Euler, Andre
    RADIOLOGY, 2022, 305 (01) : 106 - 114
  • [43] Photon-counting detector CT for abdominal imaging: opportunities and challenges
    Fides Regina Schwartz
    Hatem Alkadhi
    European Radiology, 2023, 33 : 7805 - 7806
  • [44] Photon-Counting Versus Energy-Integrating Detector CT Angiography of the Lower Extremity in a Human Cadaveric Model With Continuous Extracorporeal Perfusion
    Gruschwitz, Philipp
    Hartung, Viktor
    Kleefeldt, Florian
    Ergun, Suleyman
    Huflage, Henner
    Peter, Dominik
    Hendel, Robin
    Patzer, Theresa Sophie
    Pannenbecker, Pauline
    Kuhl, Philipp Josef
    Bley, Thorsten Alexander
    Petritsch, Bernhard
    Grunz, Jan-Peter
    INVESTIGATIVE RADIOLOGY, 2023, 58 (10) : 740 - 745
  • [45] Discrimination of Hemorrhage and Contrast Media in a Head Phantom on Photon-Counting Detector CT Data
    Risch, Franka
    Berlis, Ansgar
    Kroencke, Thomas
    Schwarz, Florian
    Maurer, Christoph J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2024, 45 (02) : 183 - 187
  • [46] A New Iterative Metal Artifact Reduction Algorithm for Both Energy-Integrating and Photon-Counting CT Systems
    Anhaus, Julian A.
    Heider, Maximilian
    Killermann, Philipp
    Hofmann, Christian
    Mahnken, Andreas H.
    INVESTIGATIVE RADIOLOGY, 2024, 59 (07) : 526 - 537
  • [47] Diagnostic limitations in advanced stage peripheral arterial disease in a cadaveric study comparing photon-counting and energy-integrating CT detectors
    Viktor Hartung
    Henner Huflage
    Anne Marie Augustin
    Sven Lichthardt
    Dominik Peter
    Florian Kleefeldt
    Süleyman Ergün
    Thorsten Alexander Bley
    Jan-Peter Grunz
    Philipp Gruschwitz
    Scientific Reports, 15 (1)
  • [48] Spectral X-Ray CT Image Reconstruction with a Combination of Energy-Integrating and Photon-Counting Detectors
    Yang, Qingsong
    Cong, Wenxiang
    Xi, Yan
    Wang, Ge
    PLOS ONE, 2016, 11 (05):
  • [49] Evaluation of run-off computed tomography angiography on a first-generation photon-counting detector CT scanner - Comparison with low-kVp energy-integrating CT
    Rippel, K.
    Decker, J. A.
    Wudy, R.
    Trzaska, T.
    Haerting, M.
    Kroencke, T. J.
    Schwarz, F.
    Scheurig-Muenkler, C.
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 158
  • [50] Comparison of Threshold Energy Calibrations of a Photon-Counting Detector and Impact on CT Reconstruction
    Rodesch, Pierre-Antoine
    Richtsmeier, Devon
    Guliyev, Elmaddin
    Iniewski, Kris
    Bazalova-Carter, Magdalena
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2023, 7 (03) : 263 - 272