An efficient Cd two-stage column system for high-precision determination of Cd isotopic compositions by double spike MC-ICP-MS

被引:3
|
作者
Zhang, Zheyuan [1 ]
Li, Tao [2 ]
Li, Baichan [2 ]
Lin, Yibo [1 ]
Li, Gaojun [3 ]
Chen, Tianyu [1 ]
机构
[1] Nanjing Univ, Sch Earth Sci & Engn, State Key Lab Mineral Deposits Res, Nanjing, Peoples R China
[2] Nanjing Inst Geol & Palaeontol, Chinese Acad Sci, Key Lab Palaeobiol & Petr Stratig, Nanjing, Peoples R China
[3] Nanjing Univ, Sch Earth Sci & Engn, MOE Key Lab Surficial Geochem, Nanjing, Peoples R China
基金
中国国家自然科学基金;
关键词
GEOLOGICAL REFERENCE MATERIALS; CADMIUM; FRACTIONATION; SEAWATER; SEPARATION; SIGNATURE; SAMPLES; INDIUM; SOILS; ZINC;
D O I
10.1039/d3ja00468f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
There has been a growing interest in using cadmium (Cd) isotopes to trace the source of Cd contamination and Cd cycling in the Earth surface. Yet it remains technically challenging to precisely and efficiently determine the Cd isotopic compositions of samples with extremely low Cd concentrations due to the imperfect separation of Cd from the matrix and the interference caused by resin-derived organics when TRU Spec resin was used. In this study, we present a two-stage column chromatography system (AG-MP-1M resin + UTEVA resin) for Cd purification. Here, a Prefilter resin combined with UTEVA resin effectively purifies Cd from Sn after the separation of Cd by AG-MP-1M column while keeping the phosphorous organic compounds to an acceptable level. In contrast to TRU Spec resin, which is prone to leaking through the Prefilter resin, we find that UTEVA resin is effectively retained by the Prefilter resin, thus avoiding the P-related anomalous shifts in the Cd isotope measurement (P/Cd < 1). UTEVA resin also exhibits a comparable capacity for purifying Cd from Sn and Mo when compared to TRU Spec resin. The recovery of the two-stage column system is generally higher than 99% and the procedural blank accounting for sample digestion and chemical purification is lower than 20 pg. The Cd isotopic compositions of several reference materials are determined using double spike MC-ICP-MS, with a Cd-111-Cd-113 double spike pair optimized for the Cd-111, Cd-112, Cd-113, and Cd-114 inversion. The delta Cd-114/110 values of these reference materials relative to NIST SRM 3108 agree within analytical uncertainty with previous studies. The long-term external precision of delta Cd-114/110 determined based on replicated measurements of BCR-2 is 0.04 parts per thousand (n = 10, 2 SD) for a minimum sample size of 10 ng. Our study thus provides an efficient two-stage column system for determining the Cd isotopic compositions of geological samples with relatively low Cd concentrations.
引用
下载
收藏
页码:1142 / 1151
页数:10
相关论文
共 50 条
  • [31] A single-stage purification method for the precise determination of zirconium isotopic composition in geological samples by double spike MC-ICP-MS
    Feng, Lanping
    Wang, Chen
    Han, Yan
    Zhang, Wen
    Guo, Jing-Liang
    Zhou, Lian
    Hu, Zhaochu
    Journal of Analytical Atomic Spectrometry, 2024, 39 (12) : 3035 - 3047
  • [32] Accurate and high-precision measurement of lithium isotopes in two reference materials by MC-ICP-MS
    Millot, R
    Guerrot, C
    Vigier, N
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2004, 28 (01) : 153 - 159
  • [33] High-Precision Mass-Dependent Molybdenum Isotope Variations in Magmatic Rocks Determined by Double-Spike MC-ICP-MS
    Willbold, Matthias
    Hibbert, Kate
    Lai, Yi-Jen
    Freymuth, Heye
    Hin, Remco C.
    Coath, Christopher
    Vils, Flurin
    Elliott, Tim
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2016, 40 (03) : 389 - 403
  • [34] High-precision iron isotopic measurements in low resolution using collision cell (CC)-MC-ICP-MS
    Wang, Jing
    Tang, Dong-Mei
    Su, Ben-Xun
    Yuan, Qing-Han
    Li, Wen-Jun
    Gao, Bing-Yu
    Chen, Kai-Yun
    Bao, Zhi-An
    Zhao, Ye
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (09) : 1869 - 1875
  • [35] High-precision Ca isotopic measurement using a large geometry high resolution MC-ICP-MS with a dummy bucket
    Li, Ming
    Lei, Yv
    Feng, Lanping
    Wang, Zaicong
    Belshaw, Nick S.
    Hu, Zhaochu
    Liu, Yongsheng
    Zhou, Lian
    Chen, Haihong
    Chai, Xinna
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (10) : 1707 - 1719
  • [36] An efficient Li dual-column system and high-precision Li isotope measurement of high matrix and low-Li samples by MC-ICP-MS
    Cao, Cheng
    Li, Tao
    Chen, Tianyu
    Li, Gaojun
    Li, Wei
    Chen, Jun
    Journal of Analytical Atomic Spectrometry, 2023, 38 (08): : 1602 - 1610
  • [37] An efficient Li dual-column system and high-precision Li isotope measurement of high matrix and low-Li samples by MC-ICP-MS
    Cao, Cheng
    Li, Tao
    Chen, Tianyu
    Li, Gaojun
    Li, Wei
    Chen, Jun
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (08) : 1602 - 1610
  • [38] Measurement on high-precision boron isotope of silicate materials by a single column purification method and MC-ICP-MS
    Wei Gangjian
    Wei Jingxian
    Liu Ying
    Ke Ting
    Ren Zhongyuan
    Ma Jinlong
    Xu Yigang
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (04) : 606 - 612
  • [39] An improved method of Cr purification for high precision measurement of Cr isotopes by double spike MC-ICP-MS
    Zhu, Jian-Ming
    Wu, Guangliang
    Wang, Xiangli
    Han, Guilin
    Zhang, Lixin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (05) : 809 - 821
  • [40] High precision osmium stable isotope measurements by double spike MC-ICP-MS and N-TIMS
    Nanne, Josefine A. M.
    Millet, Marc-Alban
    Burton, Kevin W.
    Dale, Chris W.
    Nowell, Geoff M.
    Williams, Helen M.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (04) : 749 - 765