An efficient Cd two-stage column system for high-precision determination of Cd isotopic compositions by double spike MC-ICP-MS

被引:3
|
作者
Zhang, Zheyuan [1 ]
Li, Tao [2 ]
Li, Baichan [2 ]
Lin, Yibo [1 ]
Li, Gaojun [3 ]
Chen, Tianyu [1 ]
机构
[1] Nanjing Univ, Sch Earth Sci & Engn, State Key Lab Mineral Deposits Res, Nanjing, Peoples R China
[2] Nanjing Inst Geol & Palaeontol, Chinese Acad Sci, Key Lab Palaeobiol & Petr Stratig, Nanjing, Peoples R China
[3] Nanjing Univ, Sch Earth Sci & Engn, MOE Key Lab Surficial Geochem, Nanjing, Peoples R China
基金
中国国家自然科学基金;
关键词
GEOLOGICAL REFERENCE MATERIALS; CADMIUM; FRACTIONATION; SEAWATER; SEPARATION; SIGNATURE; SAMPLES; INDIUM; SOILS; ZINC;
D O I
10.1039/d3ja00468f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
There has been a growing interest in using cadmium (Cd) isotopes to trace the source of Cd contamination and Cd cycling in the Earth surface. Yet it remains technically challenging to precisely and efficiently determine the Cd isotopic compositions of samples with extremely low Cd concentrations due to the imperfect separation of Cd from the matrix and the interference caused by resin-derived organics when TRU Spec resin was used. In this study, we present a two-stage column chromatography system (AG-MP-1M resin + UTEVA resin) for Cd purification. Here, a Prefilter resin combined with UTEVA resin effectively purifies Cd from Sn after the separation of Cd by AG-MP-1M column while keeping the phosphorous organic compounds to an acceptable level. In contrast to TRU Spec resin, which is prone to leaking through the Prefilter resin, we find that UTEVA resin is effectively retained by the Prefilter resin, thus avoiding the P-related anomalous shifts in the Cd isotope measurement (P/Cd < 1). UTEVA resin also exhibits a comparable capacity for purifying Cd from Sn and Mo when compared to TRU Spec resin. The recovery of the two-stage column system is generally higher than 99% and the procedural blank accounting for sample digestion and chemical purification is lower than 20 pg. The Cd isotopic compositions of several reference materials are determined using double spike MC-ICP-MS, with a Cd-111-Cd-113 double spike pair optimized for the Cd-111, Cd-112, Cd-113, and Cd-114 inversion. The delta Cd-114/110 values of these reference materials relative to NIST SRM 3108 agree within analytical uncertainty with previous studies. The long-term external precision of delta Cd-114/110 determined based on replicated measurements of BCR-2 is 0.04 parts per thousand (n = 10, 2 SD) for a minimum sample size of 10 ng. Our study thus provides an efficient two-stage column system for determining the Cd isotopic compositions of geological samples with relatively low Cd concentrations.
引用
下载
收藏
页码:1142 / 1151
页数:10
相关论文
共 50 条
  • [21] Accurate Measurement of Chromium Isotopic Compositions in Geological Reference Materials by Double-Spike MC-ICP-MS
    Shi, Kai
    Wu, Guangliang
    Zhu, Jian-Ming
    Wang, Xiangli
    ATOMIC SPECTROSCOPY, 2021, 42 (03) : 128 - 133
  • [22] Validating the high-precision measurement of Mo isotopes at the 5 ng level using double spike MC-ICP-MS
    Zhu, Hong-Gang
    Zhu, Jian-Ming
    Tan, Decan
    Lin, Xuan
    Lu, Kaite
    Yang, Wen
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (05) : 1063 - 1075
  • [23] Accurate and precise determination of stable Cr isotope compositions in carbonates by double spike MC-ICP-MS
    Bonnand, Pierre
    Parkinson, Ian J.
    James, Rachael H.
    Karjalainen, Anne-Mari
    Fehr, Manuela A.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2011, 26 (03) : 528 - 535
  • [24] High-precision measurement of Cd isotopes in ultra-trace Cd samples using double spike-standard addition MC-ICP-MS (vol 38, pg 950, 2023)
    Chang, Hui
    Zhu, Jian-Ming
    Wang, Xiangli
    Gao, Ting
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (04) : 1175 - 1175
  • [25] Single column procedure for quantitative separation and recovery of cadmium (Cd) for high precision isotope analysis by MC-ICP-MS
    Verheyden, Sophie
    Maerschalk, Claude
    Shiel, Alyssa E.
    Mattielli, Nadine
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2007, 71 (15) : A1063 - A1063
  • [26] Extraction of Pb and Zn from crude oil for high-precision isotopic analysis by MC-ICP-MS
    Fetter, Nadege
    Blichert-Toft, Janne
    Telouk, Philippe
    Albarede, Francis
    CHEMICAL GEOLOGY, 2019, 511 : 112 - 122
  • [27] Rapid Two-Column Separation Method for Determining Barium Isotopic Compositions Using MC-ICP-MS
    Cheng, Yishan
    Du, Yifan
    Chen, Kaiyun
    Zang, Chunlei
    Zhao, Jian
    Chen, Li-Hui
    ATOMIC SPECTROSCOPY, 2022, 43 (03) : 236 - 245
  • [28] A novel purification method for high precision measurement of Ni isotopes by double spike MC-ICP-MS
    Wu, Guangliang
    Zhu, Jian-Ming
    Wang, Xiangli
    Han, Guilin
    Tan, Decan
    Wang, Shui-Jiong
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (08) : 1639 - 1651
  • [29] High precision cadmium isotope analysis of geological reference materials by double spike MC-ICP-MS
    Peng, Huan
    He, Dong
    Guo, Rui
    Liu, Xing
    Belshaw, Nicholas S.
    Zheng, Hongtao
    Hu, Shenghong
    Zhu, Zhenli
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (02) : 390 - 398
  • [30] Precise/small sample size determination of stable Cd isotope ratios of geological samples with double spike MC-ICP-MS
    Guo, Chao
    Li, Tao
    Li, Gaojun
    Chen, Tianyu
    Li, Le
    Zhao, Liang
    Ji, Junfeng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (11) : 2470 - 2479