Application value of simultaneous multislice readout-segmented echo-planar imaging for diffusion-weighted MRI in differentiation of rectal cancer grade

被引:0
|
作者
Zhou, Mi [1 ]
Huang, Hongyun [1 ]
Li, Hang [1 ]
Yan, Guihua [1 ]
Tang, Baijie [2 ]
Chen, Meining [3 ]
Wang, Yuting [1 ]
机构
[1] Univ Elect Sci & Technol China, Sichuan Prov Peoples Hosp, Dept Radiol, 32 West Second Sect First Ring Rd, Chengdu 610072, Peoples R China
[2] Univ Elect Sci & Technol China, Sichuan Prov Peoples Hosp, Dept Pathol, West Second Sect First Ring Rd, Chengdu 610072, Peoples R China
[3] Siemens Healthineers, Dept MR Sci Mkt, Shanghai 200135, Peoples R China
关键词
Rectum; Readout-segmented echo-planar imaging; Simultaneous multislice; Apparent diffusion coefficient; Differentiation grade; FEASIBILITY; COEFFICIENT; QUALITY;
D O I
10.1007/s10334-022-01054-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective To analyze the association of apparent diffusion coefficient (ADC) values measured by readout-segmented echo-planar imaging (rs-EPI) using different simultaneous multislice (SMS) acceleration factors and the differentiation of rectal cancer grade. Materials and methods Patients with non-mucinous rectal adenocarcinoma diagnosed by biopsy (endoscope-guided biopsy or surgical resection) were retrospectively collected, and each patient underwent an MRI examination. ADC values of rs-EPI, 2 x SMS rs-EPI, and 3 x SMS rs-EPI were recorded as ADC(1), ADC(2), and ADC(3), respectively. Results The scanning time of 2 x SMS rs-EPI was 60 s, 56.2% shorter than 137 s of rs-EPI sequence, while that of 3 x SMS rs-EPI was 51 s, 72.8% less than that of rs-EPI time. The ADC value of the three groups dropped with the decrease in cancer grade (p < 0.05). The AUC values of ADC(1), ADC(2,) and ADC(3) in predicting highly differentiated rectal cancer were 0.74, 0.729, and 0.687, respectively. The difference in AUC values between ADC(1) and ADC(2) was not statistically significant (p = 0.889). Discussion SMS technology with an acceleration factor of 2 could be applied clinically to evaluate the pathological differentiation of rectal cancer grade.
引用
收藏
页码:621 / 629
页数:9
相关论文
共 50 条
  • [21] Are ADC values of readout-segmented echo-planar diffusion-weighted imaging (RESOLVE) correlated with pathological prognostic factors in rectal adenocarcinoma?
    Tang, Cui
    Lin, Mou-bin
    Xu, Jin-lei
    Zhang, Lan-hua
    Zuo, Xiao-ming
    Zhang, Zhong-shuai
    Liu, Meng-xiao
    Xu, Jin-ming
    WORLD JOURNAL OF SURGICAL ONCOLOGY, 2018, 16
  • [22] Readout-segmented echo-planar imaging in diffusion-weighted MR imaging of acute infarction of the brainstem and posterior fossa: comparison of single-shot echo-planar diffusion-weighted sequences
    Byeon, Jonghyun
    Kim, Jee Young
    Cho, A-Hyun
    CLINICAL IMAGING, 2015, 39 (05) : 765 - 769
  • [23] Diffusion-Weighted Imaging-guided MR Spectroscopy in Breast Lesions using Readout-Segmented Echo-Planar Imaging
    Sun, Kun
    Chai, Weimin
    Fu, Caixia
    Zhan, Ying
    Shen, Kunwei
    Luo, Xianfu
    Yan, Fuhua
    EUROPEAN RADIOLOGY, 2016, 26 (06) : 1565 - 1574
  • [24] Comparing the clinical utility of single-shot echo-planar imaging and readout-segmented echo-planar imaging in diffusion-weighted imaging of the liver at 3 tesla
    Xie, Simin
    Masokano, Ismail Bilal
    Liu, Wenguang
    Long, Xueying
    Li, Guijin
    Pei, Yigang
    Li, Wenzheng
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 135
  • [25] Simultaneous multi-slice readout-segmented echo planar imaging for accelerated diffusion-weighted imaging of the breast
    Filli, Lukas
    Ghafoor, Soleen
    Kenkel, David
    Liu, Wei
    Weiland, Elisabeth
    Andreisek, Gustav
    Frauenfelder, Thomas
    Runge, Val M.
    Boss, Andreas
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (01) : 274 - 278
  • [26] Diffusion-Weighted Imaging-guided MR Spectroscopy in Breast Lesions using Readout-Segmented Echo-Planar Imaging
    Kun Sun
    Weimin Chai
    Caixia Fu
    Ying Zhan
    Kunwei Shen
    Xianfu Luo
    Fuhua Yan
    European Radiology, 2016, 26 : 1565 - 1574
  • [27] Improve the image quality of orbital 3 T diffusion-weighted magnetic resonance imaging with readout-segmented echo-planar imaging
    Xu, Xiao-Quan
    Liu, Jun
    Hu, Hao
    Su, Guo-Yi
    Zhang, Yu-Dong
    Shi, Hai-Bin
    Wu, Fei-Yun
    CLINICAL IMAGING, 2016, 40 (04) : 793 - 796
  • [28] Comparison of Readout-Segmented Echo-Planar Imaging (EPI) and Single-Shot EPI in Clinical Application of Diffusion-Weighted Imaging of the Pediatric Brain
    Yeom, Kristen W.
    Holdsworth, Samantha J.
    Van, Anh T.
    Iv, Michael
    Skare, Stefan
    Lober, Robert M.
    Bammer, Roland
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (05) : W437 - W443
  • [29] The role of readout-segmented echo-planar imaging-based diffusion-weighted imaging in evaluating tumor response of locally advanced rectal cancer after neoadjuvant chemoradiotherapy
    Yang, Lanqing
    Xia, Chunchao
    Liu, Dan
    Fang, Xin
    Pan, Xuelin
    Ma, Ling
    Wu, Bing
    ACTA RADIOLOGICA, 2020, 61 (09) : 1155 - 1164
  • [30] Readout-segmented echo-planar diffusion-weighted imaging in the assessment of orbital tumors: comparison with conventional single-shot echo-planar imaging in image quality and diagnostic performance
    Xu, Xiaoquan
    Wang, Yanjun
    Hu, Hao
    Su, Guoyi
    Liu, Hu
    Shi, Haibin
    Wu, Feiyun
    ACTA RADIOLOGICA, 2017, 58 (12) : 1457 - 1467