Predictive direct power control with phase-locked loop technique of three-level neutral point clamped inverter based shunt active power filter for power quality improvement

被引:8
|
作者
Debdouche, Naamane [1 ]
Benbouhenni, Habib [2 ]
Deffaf, Brahim [3 ]
Anwar, Guessabi [4 ]
Zarour, Laid [1 ]
机构
[1] Bros Mentouri Univ, Dept Elect Engn, Lab Elect Constantine LEC, Constantine 25000, Algeria
[2] Nisantasi Univ, Fac Engn & Architecture, Dept Elect & Elect Engn, Istanbul, Turkiye
[3] Univ Bejaia, Fac Technol, Dept Elect Engn, Lab Renewable Energies Mastering, Bejaia 06000, Algeria
[4] Ferhat Abbas Univ Setif1, Dept Elect Engn, Lab Automat Setif LAS, Setif, Algeria
关键词
phase-locked loop; predictive direct power control; space vector modulation; three-level shunt active power filter; SPACE-VECTOR MODULATION; FED INDUCTION GENERATOR; SAPF; DFIG; PWM; ELIMINATION; HARMONICS; ALGORITHM; STRATEGY; VOLTAGES;
D O I
10.1002/cta.3871
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this study, an improved anti-windup proportional-integral predictive direct power control strategy with a phase-locked loop (PLL) is proposed and applied to a three-level shunt active power filter (SAPF) neutral point clamped (NPC) inverter using space vector modulation (SVM) technique. The SAPF has to ensure sinusoidal waveforms and unity power factor in the grid side, by eliminating harmonic currents and compensating reactive power of the nonlinear loads. Active and reactive powers as well as the DC bus voltage controls are performed using anti-windup proportional and integral actions with a predictive algorithm, without a need for an exhaustive mathematical model. The control law is modulated using the SVM technique allowing fixed switching frequency and low power ripples. The performances of the suggested control have been verified through an electronic STM32F407 card under diverse and severe conditions. The obtained results confirmed the expected objectives in terms of current and voltage quality, robustness, and dynamic response. Direct power control approach featuring Phase-Locked Loop (PLL), which is implemented in a three-level Shunt Active Power Filter (SAPF) neutral point clamped (NPC) inverter utilizing space vector modulation (SVM) technique. The SAPF's objective is to guarantee grid-side sinusoidal waveforms and unity power factor, while mitigating harmonic currents, compensating reactive power, reducing Total Harmonic Distortion (THD) in the current, enhancing the longevity of the filtration system, and refining the system's dynamic response.image
引用
收藏
页码:3306 / 3340
页数:35
相关论文
共 50 条
  • [31] Performance Evaluation of a Three Phase Shunt Active Power Filter For Power Quality Improvement
    Farooq, Anha
    Bhat, Abdul Hamid
    2015 INTERNATIONAL CONFERENCE ON RECENT DEVELOPMENTS IN CONTROL, AUTOMATION AND POWER ENGINEERING (RDCAPE), 2015, : 214 - 219
  • [32] Vector Shifted Model Predictive Power Control of Three-Level Neutral-Point-Clamped Rectifiers
    Zhou, Dehong
    Jiang, Changpeng
    Quan, Zhongyi
    Li, Yunwei
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2020, 67 (09) : 7157 - 7166
  • [33] Analysis, Design and Real-Time Implementation of Shunt Active Power Filter for Power Quality Improvement Based on Predictive Direct Power Control
    Aissa, Oualid
    Moulahoum, Samir
    Colak, Ilhami
    Babes, Badreddine
    Kabache, Nadir
    2016 IEEE INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY RESEARCH AND APPLICATIONS (ICRERA), 2016, : 79 - 84
  • [34] Type-2 Fuzzy Logic Controlled Three-level Shunt Active Power Filter for Power Quality Improvement
    Suresh, Dhanavath
    Singh, Saijan Pal
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2016, 44 (08) : 873 - 882
  • [35] Three-phase three-level active power filter with a clamped capacitor topology
    Lin, B. -R.
    Chiang, H. -K.
    Huang, C. -H.
    IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2006, 153 (04): : 513 - 522
  • [36] Direct Power Control Concept and Analysis for Three Phase Shunt Active Power Filter
    Chaoui, Abdelmadjid
    Gaubert, Jean-Paul
    Bouafia, Abdelouahab
    38TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2012), 2012, : 1286 - 1294
  • [37] Direct Power Control of Series Converter of Unified Power-Flow Controller With Three-Level Neutral Point Clamped Converter
    Verveckken, Jan
    Silva, Fernando
    Barros, Dionisio
    Driesen, Johan
    IEEE TRANSACTIONS ON POWER DELIVERY, 2012, 27 (04) : 1772 - 1782
  • [38] Neutral-point voltage deviation control for three-level inverter-based shunt active power filter with fuzzy-based dwell time allocation
    Hoon, Yap
    Radzi, Mohd Amran Mohd
    Hassan, Mohd Khair
    Mailah, Nashiren Farzilah
    IET POWER ELECTRONICS, 2017, 10 (04) : 429 - 441
  • [39] Flatness based control of single phase multicellular shunt active power filter for power quality improvement
    Aourir, M.
    Abouloifa, A.
    El Otmani, F.
    Aouadi, C.
    Hamdoun, A.
    Lachkar, I.
    2018 RENEWABLE ENERGIES, POWER SYSTEMS & GREEN INCLUSIVE ECONOMY (REPS-GIE), 2018,
  • [40] EMI Filter Robustness in Three-Level Active Neutral-Point-Clamped Inverter
    Shen, Zhan
    Chen, Mengxing
    Wang, Huai
    Wang, Xiongfei
    Blaabjerg, Frede
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (04) : 4641 - 4657