Predictive direct power control with phase-locked loop technique of three-level neutral point clamped inverter based shunt active power filter for power quality improvement

被引:8
|
作者
Debdouche, Naamane [1 ]
Benbouhenni, Habib [2 ]
Deffaf, Brahim [3 ]
Anwar, Guessabi [4 ]
Zarour, Laid [1 ]
机构
[1] Bros Mentouri Univ, Dept Elect Engn, Lab Elect Constantine LEC, Constantine 25000, Algeria
[2] Nisantasi Univ, Fac Engn & Architecture, Dept Elect & Elect Engn, Istanbul, Turkiye
[3] Univ Bejaia, Fac Technol, Dept Elect Engn, Lab Renewable Energies Mastering, Bejaia 06000, Algeria
[4] Ferhat Abbas Univ Setif1, Dept Elect Engn, Lab Automat Setif LAS, Setif, Algeria
关键词
phase-locked loop; predictive direct power control; space vector modulation; three-level shunt active power filter; SPACE-VECTOR MODULATION; FED INDUCTION GENERATOR; SAPF; DFIG; PWM; ELIMINATION; HARMONICS; ALGORITHM; STRATEGY; VOLTAGES;
D O I
10.1002/cta.3871
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this study, an improved anti-windup proportional-integral predictive direct power control strategy with a phase-locked loop (PLL) is proposed and applied to a three-level shunt active power filter (SAPF) neutral point clamped (NPC) inverter using space vector modulation (SVM) technique. The SAPF has to ensure sinusoidal waveforms and unity power factor in the grid side, by eliminating harmonic currents and compensating reactive power of the nonlinear loads. Active and reactive powers as well as the DC bus voltage controls are performed using anti-windup proportional and integral actions with a predictive algorithm, without a need for an exhaustive mathematical model. The control law is modulated using the SVM technique allowing fixed switching frequency and low power ripples. The performances of the suggested control have been verified through an electronic STM32F407 card under diverse and severe conditions. The obtained results confirmed the expected objectives in terms of current and voltage quality, robustness, and dynamic response. Direct power control approach featuring Phase-Locked Loop (PLL), which is implemented in a three-level Shunt Active Power Filter (SAPF) neutral point clamped (NPC) inverter utilizing space vector modulation (SVM) technique. The SAPF's objective is to guarantee grid-side sinusoidal waveforms and unity power factor, while mitigating harmonic currents, compensating reactive power, reducing Total Harmonic Distortion (THD) in the current, enhancing the longevity of the filtration system, and refining the system's dynamic response.image
引用
收藏
页码:3306 / 3340
页数:35
相关论文
共 50 条
  • [21] Harmonic Mitigation Using Three Level Bidirectional Neutral Point Clamped (BNPC) Based Three Phase Shunt Active Power Filter
    Haddad, M.
    Rahmani, S.
    Hamadi, Abdelhamid
    Javadi, Alireza
    Al-Haddad, K.
    2015 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2015, : 2526 - 2531
  • [22] Cascaded Three-level Inverter based Shunt Active Filter for Power Conditioning Application
    Patnaik, Sushree Sangita
    Panda, Anup Kumar
    2013 ANNUAL IEEE INDIA CONFERENCE (INDICON), 2013,
  • [23] Model Predictive Direct Power Control for Doubly fed induction generator based wind turbines with Three-level Neutral-Point Clamped Inverter
    Binh Quang Van Ngo
    Rodriguez-Ayerbe, Pedro
    Olaru, Sorin
    PROCEEDINGS OF THE IECON 2016 - 42ND ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2016, : 3476 - 3481
  • [24] Three-Level Active Power Filter Based on Model Predictive Control
    Gao, Hanying
    Zhang, Weihao
    Ren, Mingjie
    Liu, Xiangnan
    ELECTRONICS, 2022, 11 (09)
  • [25] Active Power Filter Control Strategy without Phase-locked Loop
    Zhang, Xiaobin
    Deng, Dan
    Zhang, Yong
    6TH IEEE INTERNATIONAL CONFERENCE ON PREDICTIVE CONTROL OF ELECTRICAL DRIVES AND POWER ELECTRONICS (PRECEDE 2021), 2021, : 875 - 878
  • [26] Direct Power Control of Three-Phase Three-Level Neutral-Point-Clamped Converters with Control Input Saturation
    Umbria, Francisco
    Gordillo, Francisco
    Salas, Francisco
    Vazquez, Sergio
    39TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2013), 2013, : 6213 - 6218
  • [27] Waveform Optimization Control of an Active Neutral Point Clamped Three-Level Power Converter System
    Zhou, Jinghua
    Li, Jin
    ELECTRONICS, 2024, 13 (10)
  • [28] Experimental Investigations on Photovoltaic Interface Neutral Point Clamped Multilevel Inverter-Based Shunt Active Power Filter to Enhance Grid Power Quality
    Boopathi, Rajendran
    Indragandhi, Vairavasundaram
    IEEE ACCESS, 2024, 12 : 74482 - 74498
  • [29] Backstepping-Direct Power Control of Three-level Four-Leg Shunt Active Power Filter
    Bouzidi, Mansour
    Barkat, Said
    2018 INTERNATIONAL CONFERENCE ON COMMUNICATIONS AND ELECTRICAL ENGINEERING (ICCEE), 2018, : 175 - +
  • [30] LQ control of a three-phase four-wire shunt active power filter based on three-level NPC inverter
    Kedjar, Bachir
    Al-Haddad, Kamal
    2008 CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING, VOLS 1-4, 2008, : 1236 - 1241